CPA900 Pressure Transducer Digital Output 4.5-5.5V DC 30-300kPa

Brand Name:Consensic
Model Number:CPA900
Minimum Order Quantity:Please contact us for details
Delivery Time:3-7 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business
Place of Origin:WUXI
Contact Now

Add to Cart

Verified Supplier
Location: Wuxi China
Address: No.86,Dicui Road,B5Building, Fourth Floor,Room 401
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details

CPA900 Better Than ± 1% Within 0℃ To 85℃ F.S. Better Than ± 1.5% Within-40℃ To 125℃ F.S.

Pin Configuration

Order NumberPipe Foot NameDescription
1VDDHVSource
2GNDGround
3NCNot Connected
4NCNot Connected
5NCNot Connected
6NCNot Connected
7OUT/OWIOutput
8NCNot Connected

Recommended Operating Conditions

ParameterSignMinimumRepresentative ValueMaximumUnit
VDDHV VoltageVDDHV4.55.05.5Vdc
Working PressureP amb30300kPa
Working TemperatureT opr-40125

Maximum Rated Parameters

ParameterSignMinimumRepresentative ValueMaximumUnitRemarks
VDDHV VoltageVDDHV-2428VAt 70℃ / 1 hour
-3036VAt 70℃ / 1 min
Analog Pin VoltageVOUT-0.35.3V25℃ , VDDHV > 5V
Simulation of Pin Currents25mA
Overload PressureP proof400kPa
Bursting Pressure of Tank ShellP burst500kPa
ESDHBM±2kV
CDM±500V
Storage TemperatureT stg-40150

Technical Specifications

ParameterSignMinimumRepresentative ValueMaximumUnitRemarks
Output Voltage RangeVOUT0.014.91V
Output Pressure AccuracyA ccp-1%1%%F.S.@0℃~85℃
-1.5%1.5%%F.S.@-40℃~125℃
Electric ResetVDDHV por2.5V
Typical Working CurrentI avdd3.1mA
Voltage Output NoiseV rms0.5mV
Output to Drive the Load ResistanceR load1kOhm
Output Drive Load CapacitorC load150nF
Short Circuit Current LimitI short _lmt1025mAOutput is short-circuit to either VDDHV or GND
Upper Limit Clamp VoltageV clamph0.012.5V@VDDHV = 5V
Lower Limit Clamp VoltageV clampl2.54.91V@VDDHV = 5V
Pinch Voltage ErrorΔ V clamp-4040mV@VDDHV = 5V
Power TimeT UP10ms
Step Response TimeT RESP0.8ms
EEPROM Data MaintenanceT live10years@125℃
China CPA900 Pressure Transducer Digital Output 4.5-5.5V DC 30-300kPa supplier

CPA900 Pressure Transducer Digital Output 4.5-5.5V DC 30-300kPa

Inquiry Cart 0