LDC11Y Pipeline Electromagnetic Flowmeter High Accuracy

Brand Name:Star merter
Model Number:LDC11Y
Place of Origin:China
Measuring range:0.05~21700m3/h
Range ratio:10:1, 15:1, 20:1, 30:1
Output:RS485, 4~20mA, 4~20mA HART, frequency/pulse, alarm output
Contact Now

Add to Cart

Verified Supplier
Location: Langfang Hebei China
Address: Address: Building 20, Tianshan International, Yanjiao Economic Development Zone, Sanhe City, Langfang City, Hebei Province
Supplier`s last login times: within 2 hours
Product Details Company Profile
Product Details

LDC11Y Pipeline Electromagnetic Flowmeter is a velocity flow meter, which is the product of the combination of fluid mechanics and electromagnetics. It consists of two parts: a flow sensor and a converter. The upper and lower parts of the measuring tube are equipped with an excitation coil, and the magnetic field generated after passing through the excitation current passes through the measuring tube, and a pair of signal electrodes are installed on the inner wall of the measuring tube to contact with the liquid, generating an induced electric potential, and the flow signal is transmitted to the converter, which is converted into a standard signal for output after the converter. It has the advantages of high precision, high stability, anti-interference, and maintenance-free.


Basic parameters
Measuring mediumLiquid (the conductivity of the measured fluid should be > 20μS/cm and compatible with the contact material)
Flow rate range0.1m/s-15m/s
Measuring range0.05~21700m3/h
Range ratio10:1 (15:1, 20:1, 30:1 can be customized)
Flow directionPositive, negative, net flow
Repeatability error1/3 of the absolute value of accuracy level
Accuracy level0.5 level, 0.2 level
Medium temperature-20℃~60℃ (Chloroprene CR lining)
-20℃~60℃ (Polyurethane rubber PU lining)
-30℃~120℃ (PTFE lining)
-30℃~150℃ (High temperature PTFE lining)
-30℃~100℃ (Fluorinated ethylene propylene F46 lining)
-20℃~150℃ (PTFE and perfluoroalkyl vinyl copolymer PFA lining)
Output signal4~20mA, frequency/pulse, alarm output, RS485, HART
Power supply85~250VAC,20~36VDC
Explosion-proof typeEx db ib q IIC T6 Gb (compound explosion-proof including isolation type, intrinsic safety type, sand filling type)
ConnectionFlange connection DN6-DN2000 (implementation standard GB/T9124.1-2019)
Protection levelIntegrated IP66
Split sensor IP66/IP68 Display box IP66
Note 1/When the split sensor is IP68, the burial depth is less than 5m and the water penetration depth is less than 3m.
Note 2/The above protection level refers to the level achieved after the electrical connection is complete.
Maximum Power≤20W
Show HeaderLCD (with backlight)
Instrument function
monitorVolume flow, mass flow, instantaneous flow, cumulative flow, flow velocity
Call the policeEmpty pipe identification alarm, electrode contamination alarm, excitation alarm
Current output
Maximum load750Ω(24V power supply)
Response frequency1Hz
Frequency Output
Frequency output range1~5000Hz
Output electrical isolationOptical isolation, isolation voltage>1000VDC
Frequency output driverField effect tube output, maximum withstand voltage 36VDC, maximum load current 250mA
Pulse output
Pulse equivalent0.001~1.000 m3/cp
n0.001~1.000 Ltr/cp
n0.001~1.000 T/cp
High level amplitude>22VDC
Low level amplitude<0.8VDC
Pulse Width50ms (square wave), automatic average square wave at high frequency
Electrical isolationOptical isolation, isolation voltage>1000VDC
Pulse driveField effect tube output, maximum withstand voltage 36VDC, maximum load current 250mA
Alarm output
Alarm output contactALMH-Upper limit alarm
ALML-Lower limit alarm
Output electrical isolationOptical isolation, isolation voltage>1000VDC
Alarm output driverDarlington output, maximum withstand voltage 36VDC, maximum load current 250mA
RS485 outputThis protocol complies with the Modbus communication protocol and adopts the RTU mode in the Modbus protocol. RS485 half-duplex working mode
(see the protocol description for details).
Environmental conditions
Ambient temperature-20~60℃
Ambient humidity0%~95%RH (no condensation and no condensation)
Electrical protection
Insulation resistance≥100MΩ 500VDC
Dielectric strength500VAC
Overall material
Lining materialNeoprene CR, polyurethane rubber PU, polytetrafluoroethylene PTFE,
high temperature polytetrafluoroethylene PTFE, polyperfluoroethylene propylene F46,
copolymer of polytetrafluoroethylene and perfluoroalkyl vinyl PFA (contacting the measured medium)
Electrode materialTitanium, Hastelloy C, Tantalum, Tungsten Carbide, Platinum, 316L (in contact with the measured medium)
Sensor housingCarbon steel/304 stainless steel
Flange materialCarbon steel/304 stainless steel
Converter housingDie-cast aluminum
Converter sealsNitrile rubber
Display window≈6mm explosion-proof glass
Connect the cablesCable between sensor and converter 2*0.5 OD 6.5mm PVC shielded cable (split type)
manual
Product Information—Chinese (CN)PDF
Product Information—English (EN)PDF
Product Selection—Chinese (CN)PDF
Product Selection—English (EN)PDF
Installation Instructions—Chinese (CN)PDF
Installation Instructions—English (EN)PDF
RS485 (RTU) Protocol Description—Chinese (CN)PDF
RS485 (RTU) Protocol Description—English (EN)PDF
HART Protocol Description—Chinese (CN)PDF
HART Protocol Description—English (EN)PDF
Key Operation Instructions—Chinese (CN)PDF
Key Operation Instructions—English (EN)PDF

China LDC11Y Pipeline Electromagnetic Flowmeter High Accuracy supplier

LDC11Y Pipeline Electromagnetic Flowmeter High Accuracy

Inquiry Cart 0