Add to Cart
Hydraulic Pump / Motor Test bench
Brief introduction
The hydraulic comprehensive test bench is a specialized equipment
used for testing and evaluating hydraulic components in maintenance
enterprises. The system selects high-quality hydraulic and
electrical components and accessories from home and abroad, and has
the characteristics of compact structure, reliable quality,
reasonable design, easy operation and maintenance,
The hydraulic system of this test bench adopts a closed oil tank
structure, which allows it to work in a dusty environment. However,
attention should be paid to regularly cleaning the dust on the
hydraulic equipment during use to ensure that the hydraulic system
has good heat dissipation and oil cleanliness.
Structural characteristics
This device uses an electric motor as the driving system for the
entire test bench, and is equipped with two oil pump motor units as
auxiliary fuel supply systems for the test bench. The test bench is
divided into four parts: fuel tank valve group power pump station
unit; Pump testing unit; Motor testing unit; Control unit. The
installation structure has the advantages of light weight, compact
structure, and easy installation.
It adopts an integrated oil circuit block design, the system has
the characteristics of low leakage, compact structure, easy
disassembly and assembly.
The output oil circuit is arranged neatly and clearly, making it
easy to operate and install.
Main parameters:
Power: 160KW+22KW+2.2KW+0.8KW+0.8KW+0.75
Maximum pressure: 35MP;
Main system flow: 550L+550L
Hydraulic pump speed: 0-1500r/min
Functional configuration and parameters of the test bench:
Function: The hydraulic comprehensive test bench can test the
following components:
Main tests: single and double hydraulic pumps; Open and closed
hydraulic pumps; Axial high-speed hydraulic motor, etc.
Drive mode: Electric motor output power of 160kw; Rotational speed
0-1500r/min
Items Tested
Displacement inspection test: No load pressure, measure
displacement.
Volumetric efficiency test: Measure the volumetric efficiency under
rated operating conditions.
Overload test: The maximum displacement, nominal speed, and rated
pressure of the hydraulic pump should be operated for less than 1
minute at 110% or maximum pressure (depending on the power of the
tested component).
External leakage: In the above test, check the leakage situation of
the sealing part.
Test accuracy: (1) Pressure: accuracy ± 0.1%, measurement range
0-35Mpa
(2) Flow rate: accuracy ± 0.5%, measurement range 5-400L/min
(3) Speed: accuracy ± 0.5%, measurement range 0-2200r/min
(4) Temperature: accuracy ± 1 ℃, measurement range -20-100 ℃