Non Polarized 2 Wire Smoke Alarm 105g For Conventional Detection Alarm System

Brand Name:XHA
Certification:CE
Model Number:XHA8015
Minimum Order Quantity:1
Delivery Time:3 Working days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
Supplier`s last login times: within 43 hours
Product Details Company Profile
Product Details

2 Wire Smoke Alarm For Conventional Detection Alarm System




Introduction

The primary purpose of a conventional smoke detector is to provide early warning of a potential fire by detecting the presence of smoke and triggering an audible alarm to alert occupants. This allows people to evacuate the area and call emergency services if necessary. it can be compartible with other brand conventional panel.


The main functions of a conventional smoke detector are:

Smoke Detection:
The smoke detector uses photoelectric sensor to detect the presence of smoke particles in the air.
The sensor reacts to the changes in the air caused by smoke, triggering the alarm.


Alarm Activation:
When smoke is detected, the smoke detector activates an audible alarm, such as a loud beeping or buzzing sound.
The alarm is intended to alert occupants to the potential fire hazard, prompting them to evacuate the area.


Power Supply:
Conventional smoke detectors can be powered by a hardwired connection to the building's electrical system.

Testing and Maintenance:
Smoke detectors require regular testing to ensure they are functioning correctly.
Periodic cleaning is also necessary to maintain their reliability.




Parameters

Product NameSmoke DetectorRated operational voltage9 to 28VDC Volts Non-polarized
Adjustable Sensitivity1.06±.26%FTStatic current≤60µA @ 24 VDC
Alarm current30mA @ 24 VDCWork temperature-10°C~+50°C
CertificationCEHumidity≤95%.
Size103*103*55mmWeight105g

Installation



INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.




Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.