Description:KF100 UV online environmental monitoring, industrial control, security monitoring
Stock:1PC
Price:$10,000.00 - $20,000.00/sets
Model NO.:KF100
Sample Gas Input and Output Interface:ø 6 Tube Fittings
Contact Now

Add to Cart

Verified Supplier
Location: Nanjing Jiangsu China
Address: Bldg 12, 2 Qingshuiting West Road, Nanjing, Jiangsu, China, 211102
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details


The KF100 Flus Gas Ultraciolet Analyzer, based on UV absorption sepctroscopy technology and chemometric algorithms, can be used to measure the concentration of SO2, NOx, O2, NH3, CL2, O3, H2S and other gases. With high accuracy, high reliability, fast response, and wide applicability, it can be widely used in online environmental monitoring, industrial control, security monitoring and other occasions. The performance indicators of the KF100 series have reached or exceeded those of other domestic and foreign competing products.



>>>Technical Features


The analyzer gets the UV absorption spectrum from the following optical technology platform that consists of a light source, a gas chamber, fibre optics, a spectrometer(including a diaphragm, holographic gratings, and a linear array detector) and other optical components.


The UV-visible light emitted from the light source enters into the gas chamber through the optical windows, where it is absorbed by the sample gas flowing through the gas chamber. Then the light carrying the absorping information of the tested sample gas is converged by a lens and coupled inyp the optical fibre. After the light is transmitted into the spectrometer through the optical fibre for light splitting and sampling, the absorption spectrum of the gas can be obtained.


By using the DOAS technology to analyze the spectrum, the concentration of relevant contents in the gas can be analyzed.


>>>Technology Comparison


ItemUV Hot-Wet MethodNDIR
Spectral RangeComplete and continuous absorption spectra obtained through holographic grating and diode array detectionNon Dispersive, characteristic absorption spectra obtained through band-pass filter
Linear ResponseHigh wavelength resolution secures linear responseband-pass filtration compromises linear response
SO2 LossHot-wet prohibits SO2 dissolutionCondensation inevitably causes SO2 loss
Sampling SystemHeat tracing. Requests only dust filtration, simple and no corrosiveCold-dry. Requests dust filtration, condensation, water removal and corrosion proof
Zero Calibration PeriodLong (DOAS algorithm)Short
Anti-InterferenceThe combination of complete & continuous absorption spectra, high wavelength resolution, DAOS algorithm erases interference from dust, moisture and background gasesVulnerable to moisture interference
Gas CellConnected by optical fiber, easy to replace and low maintenance costComplex to replace and maintenance
Maintenance
ReliabilityNo moving partsMoving parts existed


>>>Technical Specifications


SO2, NOx Analyzer
Technical PrincipleUV-DOAS
Installation typeHot-wet Extractive
Measurement Range0~200ppm, 0~1000ppm, 0~3000ppm
Zero Drift≤ ±2%F.S.
Span Drift≤ ±2%F.S.
Accuracy≤ ±1%
Response Time(T90)≤ 60s
Linearity≤ ±1%F.S.
O2 Analyzer
Technical PrincipleZirconia/Electrochemical
Measurement Range0~25%
Response Time(T90)≤ 60s
Linearity≤ ±2%F.S.
CO, CO2 Analyzer
Technical PrincipleNDIR
Installation typeExtractive
CO Measurement Range0~1000 ppm
CO2 Measurement Range0~20%
Zero Drift≤ ±2%F.S.
Span Drift≤ ±2%F.S.
Accuracy≤ ±1%
Response Time(T90)≤ 60s
Linearity≤ ±2%F.S.


Technical Data for UV gas analyzer


ProjectIndicators
SO2 Detection rangeMin:0-50ppm,Max:0-100%,
NO Detection rangeMin:0-50ppm,Max:0-100%,
O2 Detection range0-25%, Electrochemical or zirconia
Linearity error≤±1%F.S.
Repeatability≤1%
Zero drift≤±1%F.S./ week
Span drift≤±1%F.S./week
Ambient temperature5ºC~45ºC
Response time(T90)<60s
Size19" *3U*320mm
Analog interface3-way 4-20mA output,2-way 4-20mA output
Data interface4-way switch input; 8-way relay output
Communication Interface1-way RS-232,1-way RS-485(Supports Mod-bus protocol)
Power220VAC/50Hz 100W
Protection gradeIP42
Sample gas input and output interfaceØ6 Tube Fittings