Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Brand Name:Corrtest
Certification:CE, ISO9001
Model Number:CS2350M
Minimum Order Quantity:1set
Delivery Time:5-10 working days
Payment Terms:T/T, D/P
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan China
Address: Jinfeng bld. A, Intl Enterprise Center, Optics valley Ave., East lake High-tech. Zone, Wuhan, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

EIS bipotentiostat CS2350M hydrogen permeation test has two sets of built-in independent potentiostat /galvanostat. The two channels can jointly complete experiment of RRDE and hydrogen permeation test. Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data. EIS bipotentiostat CS2350M hydrogen permeation test

is the real double-channel potentiostat. Experiments can also be conducted at the same time in each channel(see below picture: the 2 channels connect to 2 coin cells).It uses Ethernet connection. EIS module is included in both channels. Each set provides full electrochemical techniques including EIS.

Applications of EIS bipotentiostat CS2350M

EIS bipotentiostat CS2350M can do all that a single-channel potentiostat can, as there are 2 sets potentiostat/galvanostat inside of CS2350M eis Bipotentiostat/Bigalvanostat. EIS bipotentiostat CS2350M can be used in the following applications, and can do testing on two samples at the same time.


(1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis

(2) Electrocatalysis such as Oxygen reduction reaction (ORR), OER, HER, CO2 reduction.
(3) Li-ion battery, solar cell, fuel cell, supercapacitor, advanced function materials, sensor, etc
(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.


One of the typical applications of EIS bipotentiostat CS2350M

Hydrogen permeation Test (HDT)

Photo of EIS bipotentiostat CS2350M hydrogen permeation test setup


CS2350M bipotentiostat is combined with H-cells. By measuring current of cathode hydrogen charging and hydrogen atoms anode oxidation, it can further calculate the diffusion coefficient of hydrogen atoms in metal and hydrogen flux.

Hydrogen permeation test principle

The electrochemical method proposed by Devanathan-Stachurski to measure the diffusion rate of atomic hydrogen in metals.

Diagram of EIS bipotentiostat CS2350M hydrogen permeation test


The device is composed of two electrolytic cells. The left one is hydrogen elimination chamber (anode chamber). A constant potential is applied on the anode surface of the specimen. The hydrogen atoms diffused from the cathode surface are oxidized on the anode surface.The right cell is the hydrogen charging chamber (cathode chamber). During hydrogen charging, the cathode current is applied on the cathode surface.


Specifications of EIS bipotentiostat CS2350M hydrogen permeation test

Specifications
Support 2-, 3- or 4-electrode systemInterface: Ethernet
Potential control range: Primary Channel: ±10V second Channel: ±10VCurrent control range: ±1A in each channel
Potential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz), 3μV (<10Hz)Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A)Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
Maximum current output: ±1A in each channelCV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHzLow-pass filters: Covering 8-decade
Potential and current range: AutomaticWeight / Measurements: 6.5kg,36 x 30 x16cm
Operating System: Windows 7/8/10/11
Electrochemical Impedance Spectroscopy (EIS)
Signal generator
Frequency range:10μHz~1MHzAC amplitude:1mV~2500mV
DC Bias: -10~+10VOutput impedance:50Ω
Waveform: sine wave, triangular wave and square waveWave distortion:<1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time: minimum:10ms or the longest time of a cycleMaximum:106 cycles or 105s
Measurement delay:0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10VCurrent compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting

Techniques- EIS bipotentiostat CS2350M hydrogen permeation test

Bipotentiostat

  • Hydrogen permeation(Diffusion) Test (HDT)
  • Rotating Ring Disk Electrode(RRDE)
  • Faradaic efficiencyTest(FE)

Stable polarization

  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)

Transient Polarization

  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)

Chrono Method

  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)

Voltammetry

  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV)
  • Square Wave Voltammetry (SWV)
  • Differential Pulse Voltammetry (DPV)
  • Normal Pulse Voltammetry (NPV)#
  • Differential Normal Pulse Voltammetry (DNPV)
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)

Electrochemical Impedance Spectroscopy (EIS)

  • EIS vs Frequency (Nyquist, Bode)
  • Galvanostatic EIS
  • EIS vs Potential (IMPE)(Mott-Schottky)
  • EIS vs Time (IMPT)
  • Galvanostatic EIS vs Time

Corrosion Measurements

  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)

Battery test

  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging (PCD)
  • Potentiostatic Intermittent Titration Technique (PITT)
  • Galvanostatic Intermittent Titration Technique (GITT)

Amperometric

  • Differential Pulse Amperometry (DPA)
  • Double Differential Pulse Amperometry (DDPA)
  • Triple Pulse Amperometry (TPA)
  • Integrated Pulse Amperometric Detection (IPAD)

Stripping Voltammetry

  • Potentiostatic Stripping
  • Linear Stripping
  • Staircase Stripping
  • Square Wave Stripping
  • Differential Pulse Voltammetry Stripping
  • Normal Pulse Voltammetry Stripping
  • Differential Normal Pulse Voltammetry Stripping

Extensions

· Data Logger

· Electrochemical Stripping/ Deposition

· Bulk Eletrolysis with Coulometry (BE)

· Rs Measurement


Application

Corrosion: Corrtest potentiostats incl. EIS bipotentiostat CS2350M have all the electrochemical techniques for corrosion measurement such as OCP, polarization curve (potentiodynamic), EIS, Cyclic polarization CPP (passivation curve), Electrochemical Potentiokinetic Reactivation (EPR), Hydrogen diffusion test, ZRA, Electrochemical noise, etc. It can be used to study metal corrosion mechanism and corrosion resistance, and evaluate the coating durability and sacrificial anode current efficiency. It can also be used for rapid screening of corrosion inhibitors, fungicides, etc.

Left: Polarization curves of Ti-alloy& stainless steel in 3%NaCl solution Right: EN of low-carbon steel in 0.05mol/LCl+0.1mol/LNaHCO3

EIS bipotentiostat CS2350M uses correlation integral algorithm and dual-channel over- sampling technique, and has strong anti-interference ability. The internal resistance of the instrument is up to 1013Ω. It's suitable for EIS measurements of high-impedance system (such as coating, concrete etc)


Salt spray aging test of high impedance coating

Energy

With techniques LSV, CV, galvanostatic charge and discharge (GCD), Constant potential/ current EIS, and precise IR compensation circuit, Corrtest potentiostats incl. EIS bipotentiostat CS2350M are widely used in supercapacitor, Li-ion batteries, sodium-ion batteries, fuel cell, Li-S batteries, solar cell, solid-state batteries, flow batteries, metal-air batteries etc. It is an excellent scientific tool for researchers in the fields of energy and materials.

Salt spray aging test of high impedance coating CV curve of PPy supercapacitor in 0.5 mol/L H2SO4 solution


Electroanalysis

Corrtest potentiostat incl. EIS bipotentiostat CS2350M includes all the voltammetric methods such as NPV, DNPV, SWV, ACV, and can be used for fast analysis of the trace elements in the solution. Voltammetry stripping methods can do the Quantitative analysis according to the stripping peak current.

Stripping voltametric curves in solution of different Pb2+, Cd 2+,Zn2+ concentration


Electro-catalysis

● Corrtest potentiostat incl. EIS bipotentiostat CS2350M can measure the half-wave potential (ORR), overpotential (HER, OER) of the catalyst, and has the function of peak power density and energy density calculation.


● Long-term cyclic measurement for ORR, OER, HER,

CO2RR by techniques such as cyclic voltammetry,

potentiostatic, galvanostatic. Faraday efficiency can be

measured with a bipotentiostat.


LSV curve of catalysts in alkaline solution

● Maximum current can be 20A and compliance voltage can be 30V, and with IR compensation technique,

Corrtest potentiostat can precisely measure the overpotential of the electrode, which is a big advantage in electrocatalysis field.


China Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test supplier

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Inquiry Cart 0