35kV Portable Cable Fault Locator with TDR and High Voltage Surge

Brand Name:XZH TEST
Certification:CE/ISO
Minimum Order Quantity:1 set
Delivery Time:5-8 work days
Payment Terms:T/T
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

XHDD503

Portable outdoor ready unit with four wheels, IP43

Very easy to use "turn&click" single

rotary knob interface

Surge/Thump energy 2,048

Joule DC testing/surging/thumping up to 32 kV, burning up to 32 kV Working power 2000VA Prelocation methods: ARC Multishot, ICE and DECAY, low voltage pulse Built-in safety circuits for earth connection monitoring (F-Ohm) and touch potential monitoring (F-Voltage)

Feature

• 10.1-inch full-color TFT touch screen;

• Embedded system, safe, stable, simple display and operation mode;

• With the function of testing cable wave velocity, cable length and fault distance;

• Fully automatic continuous sampling, waveform capture at all times, timely and accurate.

• With automatic test range setting, automatic waveform analysis and display of test distance.

• Full Chinese menu, touch and coding button two operation modes, simple, fast and reliable.

• With low-voltage pulse method, high-voltage flashover method, multiple pulse method (8 times) test technology, waveform display is smooth and easy to read.

• When using the multiple pulse method, it is used with a pulse coupler to display 8 groups of high and low voltage waveform comparisons, which is convenient for automatic test distance, manual analysis and distance measurement.

• The instrument has powerful data processing capabilities, which is convenient for users to manage and archive waveform files.

• It has a massive test waveform storage function: the waveforms tested on site can be conveniently stored in the instrument in the order specified by the Chinese naming regulations, so that they can be called up for observation and analysis at any time; it can store more than 8,000 low-voltage pulse and high-voltage flashover waveform records, and more than 250 multiple pulse waveform records. The waveform files can be imported into the computer software for management and analysis using USB communication.

• Ultra-high brightness, LED backlight brightness up to 280nit, resolution 1024*600, easy to operate in direct sunlight.

• Built-in large-capacity lithium battery pack, supports fast charging, and can be tested in an environment without power supply.

Technical Parameters

General features
Portable cable fault location system
Graphical interfaceGraphical interface, more intuitive and easy to operate.
OperationTurn and click a single knob (jog dial) on the control unit
Data managementGeneral database
Data SynchronizationUniversal Serial Bus
Control unit
DisplayIndustrial grade TFT color panel with LED backlight
Anti-glarehave
Multi-touchhave
LCD size10"
Aspect Ratio16:9
Resolution1024 x 768 Full HD
Brightness450 cd/m²
Safety
AdaptabilityCE Compliance;EN 61010,EN 50191,VDE 0104,VDE 015,DGUV 203-034(BGI 891)
Discharge and grounding devices72kJ, equivalent to the energy stored in a 10µF capacitor charged to 120kV DC fast charge: discharge time constant < 1 second
System StatusReal-time monitoring and indication
Intrinsically safeGround immediately when there is a power outage
F-U safety interlockOperating voltage connection monitoring (high voltage circuit)
F-Ohm Safety InterlockOperational earth connection monitoring (high voltage circuit)
Security FeaturesFront panel: power on/off, lockout button switch, emergency stop, residual pressure indicator light, high voltage switch; Control unit: Knob (jog dial)
Safety devicesSystem grounding status indicator, power input protection device, high voltage room monitoring through door contact, external safety device
Power input monitoringOvervoltage protection, undervoltage protection, residual current device (RCD)
Defining WiringThere is a switchboard inside the system


System function

1.Use DC or high-voltage pulse to make the cable fault point flash over and discharge

2.Use the traveling wave reflection principle to make a rough measurement of all types of cable main insulation faults

3. Use the acoustic and magnetic synchronization method to make a precise measurement of all types of cable main insulation faults

I,High voltage surge generator

Output modeDC, Single, Cycle
Output voltage0-8kV,0-16kV,0-32kV
Built-in capacitor64uF,16uF,4uF
Discharge energy2048J @ each voltage level
Impact power2000VA
Impulse rateAutomatic impact for about 6 seconds, manual impact for any control time
Surge voltage levels switchManual
Voltage adjustment typeContinuous
IndicationHigh-voltage side voltage metering, indication of output voltage and current in real time
Operating modes switchManual
CouplerBuilt-in multiple pulse sampling box
Safe protectionWith zero start protection function, safe and reliable
DischargeUnique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device
Working powerAC 220V±15% ,50Hz±2Hz(60Hz)
DC withstand voltage testingOutput voltage adjustable and indication range 0-32kV, output current indication range 0-20A
Burn currentFault conditioning (burning) with current up to
60 mA @ 32 kV, 120 mA @ 16kV, 240mA@8kV
SafetyOver-voltage, Over-current, Overheating protection.
Automatic discharge after operation
Protection ratingNot lower than IP54
Dimensions(mm)534L×444W×805H mm
Total weightNot more than 130kg
II,TDR cable fault locatorII,TDR cable fault locator
Test methodLow voltage pulse, Impulse current, Impulse voltage, ARC multipls pulse
Sampling rate1MHz~400MHz
Pulse outputUnipolar
Pulse Amplitude300V
Pulse width0.15μS/0.30μS /0.60μS/1.20μS/2.4μS/5.0μS/7.5μS/10μS
Measurement scope120km
Measurement range100m/300m/500m/1km/3km/5km/10km/25km/50km/100km
Minimum resolution0.07m
Measurement error≤±(0.5%×L+1m),L is cable length
Signal gain0…100%,adjustable
Propagation speed10…999.9m/µs
Output ImpedanceAutomatic match
TriggerAutomatic continute
Result analysisAutomatic measure fault distance
Working conditionstemperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg
III.Acoustic and magnetic synchronous cable fault pinpointer
Location modeStandard mode, enhanced mode, noise reduction mode, custom mode (ms, waveform)
Location methodIntelligent time difference method, step voltage method, electromagnetic inspection method, acoustic measurement method
Positioning accuracyFixed point: 0.1m, Path: 0.1m, Step voltage: 0.1m
DisplayTFT ultra-bright 5-inch, 800×480 true color
LanguageGraphical language is more intuitive
Gain120dB, fully automatic adjustment, also can be adjusted manually
Frequency range100~1600Hz
Dynamic Range0~112dB(16 gears)
Synchronous triggerAcoustic fully automatic synchronous trigger; magnetic field fully automatic synchronous trigger
Detection range0.00~99.99ms,75mV~75V
ProbeAutomatic mute, fully digital metal intelligent probe
Headphone350Ω strong noise reduction and anti-interference technology
Working power4*18650 Standard lithium battery
Working hoursMore than 8 hours
Ambient temperature-25~65ºC;Relative humidity:≤90%
WeightHost 0.6kg;Sensor 1.4kg
Waterproof gradeIP65


V Test cables

(Note: Due to the existence of 35kV high voltage, special high voltage cables are made and should be kept away from the site during operation.)
High voltage output cablecore wire 2.5mm2 red, withstand voltage 50kV DC, with shielding layer, outer diameter 14mm, length can be customized according to customer's requirements, including installation of large spool. Standard length of HV output cable is 5m.
Ground cablegrounding 3-column - main core 16mm2 transparent color, branch 2.5mm2, length can be customized according to customer's requirements, including installation of small spool.Standard length of ground cable is 5m.

Prelocating methods ARC Multishot: The Arc Reflection Method overlays and compares a low voltage reference trace and a high voltage fault trace captured via capacitor discharge through an inductive (coil-type) filter.

8 comparative measurements per ARM shot are displayed (Multishot feature), and the results are evaluated automatically. ICE/Surge Pulse: After fault ignition via capacitor discharge, the Impulse Current or Surge Pulse method measures the current component of the travelling wave, This technique is suitable for long cables and PILC cables.

DECAY: After fault ignition via HV DC source, the DECAY method measures the voltage component of the travelling wave. This technique is suitable for very long cables, HV transmission cables and faults with very high breakdown voltage.

IFL: Intermittent Fault Locating; to find intermittent faults with temporarily changing characteristics like they often occur in street lighting systems.

V Test cables


V Test cables

I,Highsurge generator

I,High voltage surge generator

System function

System fu


China 35kV Portable Cable Fault Locator with TDR and High Voltage Surge supplier

35kV Portable Cable Fault Locator with TDR and High Voltage Surge

Inquiry Cart 0