Add to Cart
Model number | Product name |
XHGG502A | Cable fault pre-locator |
XHDD503C | Cable fault pinpointer |
XHGX507 | Cable fault comprehensive tester |
XHHV535-4TSC | High voltage surge generator |
Sampling frequency | 1MHz~400MHz |
Low voltage pulse amplitude | 300V±15% |
Ranging range | ≥120km |
Test range | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km |
Pulse width | 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS |
Minimum resolution | 0.07m |
Test blind area | ≤10m |
Measurement error | ≤±(0.5%×L+1m), L is the cable length |
Power supply mode | charging AC110V~240V, 50Hz/60Hz |
Pulse coupler withstand voltage | DC 35kV |
Volume and weight | L358mm×W284mm×H168mm-4.7kg |
Working conditions | Temperature -20ºC~+65ºC, relative humidity 90%, atmospheric pressure 750±30mmHg |
1 | Filter parameters | All-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz. |
2 | Channel gain | 8 levels adjustable. |
3 | Magnetic channel gain | 8 levels adjustable. |
4 | Output gain | 16 levels (0~112db) |
5 | Output impedance | 350Ω |
6 | Acoustomagnetic positioning accuracy | less than 0.2m. |
7 | Path identification accuracy | less than 0.5m. |
8 | Power supply | 4*18650 standard lithium batteries. |
9 | Standby time | more than 8 hours. |
10 | Volume | 428L×350W×230H |
11 | Weight | 6.5kg. |
12 | Ambient temperature | -25~65ºC; Relative humidity: ≤90%. |
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz) |
Working mode | direct connection method, coupling method (caliper method), induction method |
Matching load | 5 ohms-3000 ohms |
Impedance display | 5 digits |
Overheating and over current | automatic protection |
Power output | low gear, middle gear, high gear |
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz), Passive frequency 50Hz |
Antenna mode | valley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame) |
Current indication | display the effective current value of the cable under test (unit: mA) |
Working temperature | -10ºC+55ºC |
Power indicator | graphic display |
Battery life | continuous work> 8 hours: intermittent work> 16 hours |
Signal strength indication | ladder diagram, digital range 0-999 |
Gain control | manual adjustment, dynamic range of 100dB |
Detection depth | the maximum detection depth is around 10 meters |
Maximum detection distance | The cable with good insulation can be up to 15km in the direct connection method |
Depth measurement | press the depth key to display three digits, the maximum depth can be measured up to 10 meters |
Accuracy | Low frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m |
Item | Name | Qty. |
1 | Receiver | 1 |
2 | Transmitter | 1 |
3 | Direct connect signal line | 1 |
4 | Coupling line | 1 |
5 | Ground pin | 1 |
6 | Charger | 1 |
7 | Ground wire | 1 |
8 | A-frame | 1 |
9 | A-frame connect line | 1 |
10 | A-frame probe pin | 2 |
11 | Transmitting clamp | 1 |
12 | Receiving clamp | 1 |
Impulse high voltage | 0~32kV, 0~16kV, 0~8kV three gear adjustment |
High voltage partial pressure | 1.5 level |
Built-in capacitor | 4μF/32kV,16μF/16kV,64μF/8kV Adjustable three-speed adjustment |
Discharge power | 0-2048J at each voltage level |
Impact power | 2KVA |
Burn current | 60m A @32kV, 120mA@16kV, 240mA@32kV |
Output voltage polarity | negative polarity |
Impact time | about 6-7 seconds for automatic impact, arbitrary control time for manual impact |
Indication | High-voltage side voltage metering, indication of output voltage and current in real time |
Operating mode | Single trigger, cycle, DC |
DC withstand voltage testing | Output voltage adjustment and indication range 0-32KV, Output current indication range 0-20A |
Safe protection | With zero start protection function, safe and reliable . Overvoltage, Over-current, Overheating protection. Automatic discharge after operation. |
Connecting cable | High voltage output cable: 5m, Protective earthing cable:5m, power cable: 3m |
Over temperature protection | 85ºC |
Volume(mm) | 550L×500W×1000H |
Weight | not more than 130kg |
Power supply | AC220V±10%, 50Hz±2Hz |
Ambient temperature | -20~+50ºC |
Protection rating | Not lower than IP54 |
Certificate | CE ISO |