Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing - xzhtest

Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing

Brand Name:XZH TEST
Certification:CE, ISO
Model Number:XHTX201D
Minimum Order Quantity:1 unit
Delivery Time:5-8 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Address: Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Xzh Test Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing

Product Description


XHTX201D CT/PT ANALYZER is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, Degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopt LCD, self-equipped minitype printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

Main features

Support for detecting CT and PT both

  1. All inspection items can be completed in a single instrument without external auxiliary equipment.
  2. With intelligent controller, which is easy to operate.Large screen LCD, graphdisplays the ports.
  3. Automatically give 5% and 10% error curves.
  4. 3000 sets of test data can be saved and will not be lost even after power failure.
  5. Support U disk save the data, can be read through a standard PC, and generate a WORD report.
  6. It's compact and lightweight, its weight is less than 22Kg, very good for field testing.

Major Test Functions and Technical ParametersFunction Table

I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization Curve1. Excitation Characteristic Test
2. Transformation Ratio Test2. Transformation Ratio Test
3. Polarity3. Polarity
4.5% and 10% error curve4. Withstand Test of Power Frequency Alternating Current
5. Current Injecting5. Degauss
6. Degauss6. Calculation of Knee Point Value
7. Withstand Test of Power Frequency Alternating Current7. Actual Secondary Load Test
8. Automatic Calculation of Excitation Knee Point Value8. Resistance Test
9. Actual Secondary Load Test
10. Resistance Test
Technical Parameter Table
Major Technical Parameters
Operational Power Supply:AC220V±20V, 50~60Hz
Equipment Power Supply Output Waveform:Sine Wave
Single Machine Output Voltage of Excitation Characteristic:0~2500V
Excitation Output Current:0~20 A
Single Machine Output Current of Transformation Ratio Test0~1000A
CT ratio measurement range5~25000A/5A(5000A/1A)
PT ratio measurement range1~500KV
Load Range5~1000VA
Resistance measurement range0.1~300Ω
Error:≤0.5%(0.2%*Reading+0.3%*Range)
Operating Temperature:-10ºC~+40ºC
Relative Humidity:<90RH%
Altitude≤1000m
Overall Dimension(Length×Width×Height):400 *200 * 260(mm)
Weight:≤23 Kg
China Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing supplier

Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing

Inquiry Cart 0