Transformer capacity tester XHTX1318AJ is specialized in bad power users evading basic electricity fee and secretly adding capacity problems and is a new-type high precision instrument specially used for the measurement of the transformer capacity and characteristic parameters. This product use wide-screen color LCD , English display, simple and quick menu operation, human-machine interface is very friendly. There is a built -in rechargeable battery inside the instrument and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets of transformer. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the voltage regulator, current regulator and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of your work.
This is a multi-functional measuring instrument, which is
equivalent to two common meters: such as active transformer
capacity tester plus transformer parameter tester. It can be used
for test transformer capacity, type, no-load current, no-load loss,
load loss, impedance voltage and so on.
This product has many advantages such as small dimension, light ,
high accuracy, good stability, simple operation and so on. It can
replace of the commonly many meters, you can measure the
transformer loss and capacity with simple wiring and convenient
testing in only one this kind of instrument so that the work
efficiency can be greatly improved.
Function
Transformer capacity and characteristic test is a professional test. There are many contents and items in transformer testing ,it is needed to use uniform terms to describe and define these characteristic and process under test
In the transformer with tapped winding, every tap in this winding stands for a fixed turns number of winding in this tap, which also means a fixed turns number ratio of winding between this tap winding with other constant winding
Tap corresponds to the rated parameters of transformation.
Attention: The data of load/no-load loss and no-load current is the data of transformer under the principal tapping (except for appointed other taps)
It is the device that is used to change the position of tap winding of transformer under the operating with excitation or on-load.
It is the device that is used to change the position of tap winding of transformer under operating no-load or without excitation.
When rated voltage (tapped voltage) under rated frequency is applied to terminal of one winding and the circuit of other windings are open, in this case ,the active power consumed is No-load loss.
Note 1: For three phase transformer, it is the average of current of three phase terminals.
Note 2: Generally use the percentage of the rated current to display. For the multi-winding transformer, it is based on the winding with the max rated capacity.
in one pair of winding, when rated current flows through the line terminal and make short circuit of the other winding under the rated frequency and referenced temperature,in this case, the active power consumed is called load loss, at the same time ,other winding if there is , please make the circuit open .
Note1: For the double winding transformer, there is just one pair of winding and one value of load loss.
For multi-windings transformer, there are multi pairs and values of loading loss,the total load loss should be corresponding to the load loss of appointed winding combination.
Note2: When the rated capacities are different for two windings in a winding combination(or wingding portfolio), the load loss should be based on the rated current value of the windings with the minimum rated capacity, and should appointed out the reference capacity.
The sum of no-load loss and load loss
Generally, short circuit impedance is the impedance value of a pair of winding Under the rated frequency and reference temperature, the equivalent series impedance in one winding of a pair windings between the terminals of this winding is
Z=R+jX(Ω). To figure out the value, the terminal of the other winding need to short circuit. If there are other windings, they need to open circuit.
Note1: For the transformer with tapped windings, short circuit impedance need to be the appointed tap, if there is no special instruction, it means the principal tap. For three-phase transformer, it means the impedance value of a single phase if the circuit is in equivalent star connection.
Note 2: It can be represented using non-directional relative value that means fraction value Z of the reference impedance value Zref in same winding of one pair windings, is as follows
the Formula is suitable for the three phase and single phase
transformer.
U——Voltage of Z and Zref in windings(rated voltage or tapped
voltage)
Sr——Basic value of rated capacity.
The relative value is equal to the ratio between the applied voltage and rated voltage (tapped voltage) when operator wants to get the corresponding rated current (tapped current) in short circuit test. This voltage is also called the short-circuit voltage of this pair windings. It is generally expressed as a percentage.
Technical Parameters
The output range of built-in battery
Voltage:0~10V
Current:0~10A
The input range of characteristic test power source
Voltage:0~750V
Current:0~100A
Accurate of test
Voltage, current:±0.2%
Power:±0.5%(CosΦ>0.1), ±1.0%(0.02<CosΦ<0.1)
Working temperature: -20℃~+60℃
Requirement of charger
Electric supply AC160V~265V
Adapter output 12.6V 1000mA
Insulation
⑴ Insulation resistance between capacity , voltage, current to
enclosure ≥100MΩ
⑵ bear the 2kV power frequency (effective value) between the
input power and machine enclosure, testing time is 1 minute.
Volume :32cm×25cm×12cm
Weight: 2.5KGS
Operation panel diagram
The operation panel is like figure 1 : including printer , LCD,
keyboard, the wiring hole of capacity test , binding post of
characteristic test and communication interface.
Main Menu
After open the power switch, automatic enter into the main menu
interface (see Figure 2) Main Menu includes: "Transf. power ", "No
- load loss", "Load loss", "Data Browser", "System Settings" five
Items. You can use the "↑", "↓", key to select the needed function
and click "OK" to enter.
At the same time, the instrument according to the system's internal clock chip, can accurately display the present time.
Company profile
XZH TEST is a professional cable fault detection equipment manufacturer. We are a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.
Since its inception in 2013, our company has grown to become one of the largest manufacturer of underground cable fault detection equipment in China. An ISO 9001 and CE certified company, we produces a broad range of testing equipment.
What we can do
We have the ability to innovate new products and technologies.
We can provide complete system solutions for your project.
We provide online and offline practical and theoretical training.
We provide instrument repair and calibration.
FAQ
1. Are you a trading company or a manufacturer?
We are a professional manufacturer with more than 10 years of
experience. We can strictly control the quality of parts and
finished products.
2. What is the delivery time and inventory?
If our best-selling products are in stock, it will be 5-8 working
days for shipment. But for mass production and customized
production, the time will take 2-4 weeks.
3. What are your payment terms?
Payment ≤ USD 2000, 100% T/T prepayment. Orders over USD 2000 can
be negotiated.
4. How long is your product warranty?
We provide 1 year warranty for the equipment.
5. How do you ensure quality?
The product links include R&D, manufacturing, commissioning and
technical support, following strict and scientific management
principles. Therefore, we can support strong production and R&D
capabilities, and can produce high-quality products at competitive
prices to meet customers' high requirements.
6. What support can I get?
We will provide training support, marketing support, technical
support and supply chain support. You can contact us for more
information.
7. Where is your factory? Can I visit your factory?
We are located in Xi'an, Shaanxi, China. We are close to Xi'an
Xianyang International Airport, which is about 2 and half hours by
plane from Shanghai and Guangzhou. All customers from all over the
world are welcome to visit us.
8. How to become your dealer?
Every company interested in power system instruments can contact us
without hesitation, including website letters, emails, telephones,
etc. We will contact you quickly according to your company
information and cooperation intentions.