Product Description:
The heat recovery ventilator features an enthalpy exchange
efficiency of 60% to 65%, which means that it is able to recover a
significant amount of heat and moisture from the exhaust air and
transfer it to the incoming fresh air. This not only helps to
reduce energy consumption, but also ensures that the indoor air
quality remains healthy and comfortable for occupants.
In addition to its high efficiency enthalpy exchange, the HRV
product also boasts an impressive temperature exchange efficiency
of 50% to 55%. This means that it is able to provide effective
heating and cooling with minimal energy consumption, resulting in
lower operating costs and a reduced carbon footprint.
Features:
- Energy saving ventilation:effective recycle the heat loss of
ventilation (fresh air load),can cut down the cost of air
conditioning.
- Saving function:because you can greatly reduce the load of fresh
air ,and part of the heat energy can be recovered,the air
conditioning equipment can be properly miniaturization.
- Wet function:when refrigeration-lower the high humidity of the
incoming air,get close to the indoor humidity air.When heating,Make
the incoming winter dry air close the indoor air humidity.
- Comfortable ventilation,ventilation of indoor temperature change is
small,due to incoming air and platoon air at the same time,can be
stable at hign closed room ventilation.
- Sound effects:Machine body air duct,heat exchanger core with sound
insulation effect,can prevent the outdoor noise introduced into the
house,or prevent indoor noise to the outside,not destroy the office
public environment etc.
Technical Parameters:
Technical Parameter | Value |
---|
Air Flow | 200 To 10000 M3/h |
Power Supply | 1-phase, 208-230V, 60Hz & 3-phase, 380-415V, 60Hz & 3-phase,
208-230V, 60Hz |
ESP | 75 To 400 Pa |
Function | Heat Exchange |
Temperature Exchange Efficiency | 50% To 55% |
Enthalpy Exchange Efficiency | 60% To 65% |
Indoor Unit Types | Heat Recovery Ventilator (HRV) |
How it works:
When air flow formed by exhaust air and outdoor air through the
heat exchanged core in cross way, because of temperature difference
in the two sides of flat partition board. the heat transmission is
occurred.
In summer, outdoor air acquire cooling from air exhaust to decrease
environment temperature; In winter, outdoor air acquire heating
from air exhaust to increase temperature, that is to say, it
realizing the energy recovery during air exhaust process to
exchange the heating in heat exchanged core to outdoor air.
Application for: business office buildings, hotels, restaurants,
meeting rooms, exhibition centres, leisure centres, workshop and
other places.