Customized Design Pole Mount Cabinet With Battery PDU And Power Distribution

Brand Name:daxin
Certification:CE
Model Number:DAXIN-7058350
Minimum Order Quantity:1pcs
Delivery Time:15-25 days
Payment Terms:T/T, MoneyGram, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: Green Base Industrial Park, Longtian Street, Pingshan District, Shenzhen
Supplier`s last login times: within 21 hours
Product Details Company Profile
Product Details

Customized design Pole Mount Cabinet with Battery PDU and power distribution

Quick Details:

  • Product Name: IP 55 Outdoor Telecom Cabinet
  • Protection level: IP55
  • Cabinet Lock: Round lock
  • Surface Coating: Outdoor Powder Coating
  • Applications:
    • Telecommunication/Transportation/Renewable Energy/Outdoor Events

Pole Mount Outdoor Telecom Cabinet Technical Parameters:

ModelDAXIN-7058350
Product Name

Outdoor Telecom Cabinet

ManufacturerShenzhen Daxin
Cabinet DimensionW700mm*D580mm*H350mm
IP LevelIP54/IP55/IP65
Material1.5mm galvanized steel, single wall
Mounting WayPole mount
Cabinet LockRound Lock
AccessDoor sensor
Battery ShelfTwo shelves
Fan1 fans on the top
ColorRAL7035
Surface finishOutdoor Powder Coating
Orther accessoryBattery
UPS
PDU
Fan

Cabinet Environmental Parameter

Environmental parametersEnvironmental conditions for useTransportation environmental conditionsStorage environmental conditionsconform tonotes
typeparameterunitRelevant standards
Weatherexternal temperaturelow temperature-40-40-25YD/T1058-2000中"-40℃ Can start at full load,
high temperature4570554.1.1and4.1.2"+55~+65℃Linear derating20%.
temperature variation℃/min/1/ETS300019-2-2T2.3
humidityrelative humidity%5-9090(40±2℃)/YD/T1058-2000中4.1.3Short term testing requirements: 0-95%, maximum value of 95%, non condensing
air pressurelow pressureKpa867070YD/T1058-2000中4.1.4Only apply to modules
high atmospheric pressureKpa106106106
altitudem≤4000When the altitude exceeds 2000m, for every 100m increase, the temperature decreases by 0.5 ℃

Electrical characteristics


1 Input characteristics
Serial Numberprojecttechnical requirementunitnotes
1.1Input Voltage90—300Vac176-300Vac full load output, 90-175Vac reduced load output
1.2Input maximum current57A
1.3Input Rated Voltage220VacPhase voltage
1.4Input voltage frequency47—63(The typical value is50/60)Hz
1.5Input power factor≥0.99Full load working state
2 output characteristic
Serial Numberprojecttechnical requirementUnitnotes
2.1Output rated voltage-54VdcIN220Vac
2.2Output voltage range-42— -58VdcAdjustable through monitoring (test condition: no load)
2.3Output rated current150A
2.4Output Rating Power8.7KW
2.5Output ripple and noise≤200mVp-pThe oscilloscope bandwidth should be20MHz,
Probe parallel with 10u+104 capacitor
2.6Startup output delay3—8SIN 220Vac,
2.7Voltage stabilization accuracy≤±1%
2.8Noise indexBroadband clutter≤100mV3.4—150 KHz
Sound voltage≤30mV150—30 MHz
Telephone balance weight≤2mV
noise voltage
2.9dynamicsovershoot amplitude△V:≤5%Vo25%—50%—25%
in response torecovery time△t:≤500µS50%—75%—50%load change
2.1Unequal current distribution≤5%Module parallel 50% -100% rated output
(Functional modules can work in parallel)
2.11temperature coefficient±0.02%/℃
2.12output efficiency≥95%220Vac/Rated load (typical value), high-efficiency module
≥92%220Vac/Rated load (typical value), universal module
≥87%110VAC/rated load