Product Details
Barrier Gate Dual Channel Loop Sensor | High Accuracy & Wide
Temp Range & Direction Logic
The JUTAI Barrier Gate Dual Channel Loop Sensor (Models LD-200/LD-202) is engineered to deliver unmatched
precision and reliability for automated barrier systems in
high-traffic environments. Featuring dual-channel independent control, it ensures high-accuracy vehicle detection with 16-level sensitivity adjustment (0-F) across a 20–2000μH inductance range, capturing everything from motorcycles to heavy trucks. The
sensor’s advanced direction logic utilizes time-sequence analysis to determine vehicle entry/exit
direction with <1-second latency, enabling intelligent barrier
control in parking lots, toll lanes, and secure facilities. Built
to endure extreme conditions, the IP67-rated aluminum housing operates flawlessly in a -40°C to +70°C temperature range, resisting dust, moisture, and corrosive elements for year-round
reliability.
In smart parking systems, the LD-202’s direction logic prevents tailgating by triggering
barrier closure only after confirming vehicle clearance, while
Channel 1 ensures rapid gate opening (≤10ms response). For industrial gate control, the sensor’s wide temperature tolerance maintains stable
performance in freezer warehouses or desert sites, and its 40–80KHz anti-crosstalk technology blocks interference from nearby detectors or EV chargers. A recent
deployment at a Middle Eastern logistics park reduced unauthorized
access by 40% through real-time directional monitoring. The
sensor’s universal 12-24V DC/100-240V AC input supports solar and grid power, while SPDT relay outputs integrate seamlessly with barrier controllers, license plate
recognition systems, and IoT platforms for centralized management.
JUTAI prioritizes ease of deployment and compliance: plug-and-play DIN-rail mounting reduces installation time to 15 minutes, and auto-reset functionality ensures uninterrupted operation during voltage fluctuations.
Certified for CE, FCC, and RoHS, it meets global safety and environmental standards. Backed by a 5-year warranty and 24/7 technical support, the JUTAI Dual Channel Sensor is the
definitive choice for engineers seeking durability, precision, and
intelligent barrier control—where cutting-edge direction logic
meets industrial resilience.
Feature
- 1. 15-2000 μh detection Range
- The loop detector supports a wide detection range from 15 µH to
2000 µH, accommodating various loop sizes and configurations for
versatile application in different traffic detection scenarios.
- The wide detection range enables our loop detector to detect all
kinds of vehicles, motorcycles, cars, Ultra long truck, buses and
so on
- 2. Compact Side
- The compact and well-engineered housing combines all industry
requirements for features and functionality, allowing this detector
to be incorporated into any existing traffic detection system.
- 3. Diagnostic Capabilities & LED Indication
- Comprehensive diagnostics capabilities enable accurate diagnosis of
loop and installation problems and shows through the LED state,
ensuring optimal performance and reducing downtime.
- 4. Selectable Presence Time
- The output of the presence relay can be selected to limit a detect
output to a fixed time (greater than 30 minutes) while a vehicle
remains on the loop, providing flexibility in traffic management.
- 5. Automatic Sensitivity Boost (ASB)
- This feature reliably detects large truck-trailer combinations and
high-bed vehicles by automatically boosting the sensitivity to
maximum upon vehicle detection, ensuring accurate identification.
- 6. Automatic Environment Drifting Compensation
- Loop detectors (or other sensors) automatically adjust and
calibrate themselves to changes in environmental conditions,
maintaining detection accuracy and stability despite varying
weather and environmental factors.
- 7. 17 Dip Switch Setting
- The dip swich design on the shell makes the setting of loop
detector easier and clearer, which is very user-friendly for users.
Users can set all the functions first and then install the loop
detector.
- 8. Dual Channels work Cooperatively or Independently
- Dual channel loop detector can be used as two single channel
versions, Supports two independent detection channels.
- Also allowing for the simultaneous monitoring of multiple loops,
loop detector has the ability to recognize direction in
single-channel applications. enhancing the flexibility and accuracy
of vehicle detection.
- 9. Anti-crosstalk interference.
- Through the dip Switch, the frequency of the loop detector can be
adjusted to prevent crosstalk interference caused by the
installation of two loop coils too close.
Connections
Modes Of Operation
The LD-200 series detector may be configured for any one of the
following modes:
Presence Mode | Pulse Mode |
AB Logic Presence Mode(Barrier Operation) | AB Logic Pulse Mode(Counting Logic) |
Indicates And Switch
❀Power Led: RED Power LED Indicates “Power ON”
CH1 Detecting Led:Continuously On: Indicates vehicle detection.
Blinking Slowly: Indicates loop is short circuit or the number of
twists after the loop is not enough.
Blinking Fast: Indicates loop is open circuit or too many twists
after the loop.
CH2 Detecting Led:Continuously On: Indicates vehicle detection.
Blinking Slowly: Indicates loop is short circuit or the number of
twists after the loop is not enough.
Blinking Fast: Indicates loop is open circuit or too many twists
after the loop.
❀Sensitivity Selection
Sensitivity and frequency of the loop can be adjusted by 7-way dip
switch and 10-way dip switch setting.
User can select 8 different setting by changing the setting of the
dip-switch to different modes as in the dip-switch setting tables below. Dip switch 6, 7 and 8 for CH1
sensitivity selection with 0.8 being the least sensitive and 0.015
being the most sensitive.
Dip switch 3, 4 and 5 for CH2 sensitivity selection with 0.8 being
the least sensitive and 0.015 being the most sensitive.
❀Switch1=S1:Channel 1 Loop Function Selection (10 Way Dip Switch)
(Switch1=S1)D3,D4,D5 and(Switch2=S2)D1,D2 Setting Special
Functions(Mode1,2,3 Direction Detection. Mode4,5,6 Normal mode, two loop detection are
separated.)
Reset Button: Please note: The LD-200 must be reset every time a
setting change is made to the Dip switches.
Loop Installation
The loops are sealed using a “quick-set” black epoxy compound or
hot bitumen mastic to blend with the roadway surface.
When installation, please keep the product plug and socket in the
vertical direction
Trouble Shooting
Product Series
LD-100 | LD-102 | LD-200 | LD-202 | JTHT-11 |
Single Channel 100-240 V AC |
Single Channel 12-24 V AC/DC |
Dual Channel 100-240 V AC |
Dual Channel 12-24 V AV/DC |
Loop cable 305 m Teflon coil |
LCR-MT | | | | |
Multimeter | | | | |
Company Profile
Our company is dedicated to the research and development as well as
system integration of security products, achieving an intelligent
one unified platform that integrates access control, parking
management (parking charging system and parking guidance system),
traffic lights system, and other functionalities.
Additionally, we have pioneered self-innovation, introducing
pioneering concepts in both infrared detection and radar sensing
devices. Our innovative technologies consistently lead the
industry, and for our clients, we provide premium products, novel
application concepts, comprehensive system solutions, and
comprehensive technical support.
At JUTAl, we believe in the limitless pursuit of technology. Our
research and development philosophy centers around diligence and
excellence, striving for continuous improvement. Our ultimate goal
is to transcend current standards, providing safer and more
convenient services for our living spaces. We firmly believe that
our greatest success lies in the success of our customers.
Innovation, transcendence, and excellence are our guiding
principles.