Product Details

Bulk Sale CAT6A SFTP CPR Dca-s2,d2,a1 LSZH Network Cable for Commercial Projects



Bulk Sale ITI-LINK ITI-CTSF6A-016 CAT6A S FTP CPR Dca-s2,d2,a1 LSZH Industrial-Grade Shielded Network Blue Cable

ITI-LINK is thrilled to introduce the ITI-CTSF6A-016, a top-tier CAT6A S FTP cable meticulously crafted for commercial projects demanding high-speed, reliable network connectivity. Offered in convenient 500ft bulk reels, this industrial-grade shielded network cable features a CPR Dca-s2,d2,a1 certified LSZH blue jacket, making it an ideal choice for large-scale deployments in data centers, corporate offices, and industrial facilities. With its dual-layer shielding and 10Gbps data transfer rate at 550MHz, the ITI-CTSF6A-016 ensures seamless performance even in environments prone to electromagnetic interference (EMI) and radio-frequency interference (RFI).

Unmatched Signal Integrity with 23AWG Oxygen-Free Copper

The ITI-CTSF6A-016 is constructed with four pairs of 23AWG oxygen-free copper conductors, engineered to minimize signal loss over extended distances. This design guarantees consistent 10Gbps data transfer across the 500ft length of each reel, making it perfect for setting up expansive network backbones in server farms, financial institutions, and smart building networks. The cable’s LSZH blue jacket not only meets stringent fire safety regulations but also ensures zero halogen emissions and minimal smoke production, making it fully compliant with the safety codes of healthcare facilities, educational institutions, and commercial buildings.

LSZH Blue Jacket: Safety, Visibility, and Professional Appeal

The distinctive LSZH blue jacket of the ITI-CTSF6A-016 offers multiple benefits:
  • Enhanced Fire Safety: Adhering to EN 50265-2-1 and IEC 61034 standards, the jacket significantly reduces the release of toxic fumes and smoke during emergencies, ensuring a safer environment for occupants.
  • Streamlined Installation: The high-visibility blue color helps reduce misrouting errors by up to 35% in complex network setups, allowing for quicker and more accurate installations in data centers and office buildings.
  • Professional Aesthetics: The sleek blue hue adds a touch of professionalism and seamlessly integrates with various architectural designs, making it a popular choice for cleanroom environments, hospitals, and modern office spaces.

Technical Specifications for Future-Ready Networks

  • Bandwidth: 550MHz, supporting future upgrades to 25GBASE-T/50GBASE-T standards.
  • Jacket: LSZH (Low Smoke Zero Halogen), CMX-rated for use in plenum spaces.
  • Certifications: UL, CPR Dca-s2,d2,a1, CE, RoHS, IEEE 802.3ab, ensuring the highest quality and safety standards.
  • Warranty: Backed by a 25-year performance guarantee and 24/7 technical support, providing peace of mind for long-term network investments.

Exclusive Bulk Order Advantages for Wholesale Buyers

  • Competitive Pricing: Enjoy attractive volume discounts starting from 20 reels, making it a cost-effective solution for large-scale projects.
  • Rapid Fulfillment: With a daily production capacity of 2,000 reels, we can meet tight deadlines and ensure prompt delivery for urgent network installations.
  • Customization Options: Tailor your order with branded reels, custom color-coded jackets, and cut-to-length services to suit your specific project requirements.

Why ITI-LINK’s CAT6A S FTP Cable Stands Out?

The ITI-CTSF6A-015 combines industrial-grade durability, advanced shielding technology, and superior safety compliance, all wrapped in a high-visibility blue LSZH jacket. Whether you’re a system integrator, network contractor, or IT manager overseeing a commercial project, this CAT6A S FTP cable offers the perfect blend of performance, reliability, and aesthetic appeal.
Don’t miss out on the opportunity to upgrade your network infrastructure with the ITI-CTSF6A-016. Contact us today to discuss bulk pricing, request a free sample, and experience the ITI-LINK difference for yourself!

Technical Parameters:

Cable TypeCAT6A SFTP Ethernet Cable
Jacket MaterialLSZH
Conductor Size23AWG
Frequency500MHz
Length500Feet
Conductor MaterialCopper
Jacket ColorBlue
Shielding TypeSFTP

Product Description:Bulk Sale CAT6A SFTP CPR Dca-s2,d2,a1 LSZH Network Cable for Commercial Projects
Rev.: AECN Description:
Construction Item DescriptionElectrical Property

Conductor


Material

Bare Solid Copper(elongation:

19-24%)

Conductor Resistance at 20°C≤ 9.5 Ω / 100m
OD23 AWGResistance unbalance within a pair≤ 2%

Insulation

Material

PE Skin-Foam-Skin

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

>1500 MΩ / 100m

OD1.35 ±0.01 mmMutual capacitance5600 pF / 100m MAX
Average THK0.38 mmCapacitance unbalance pair to ground at 800Hz or 1 kHz≤ 160 pF / 100m

Color

1p: white + 2 blue stripes & blueCharacteristic impedance at 100MHz100 ± 15 Ω
2p: white + 2 orange stripes & orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min


No breakdown

3p: white + 2 green stripes & greenMechanical Property
4p: white + 2 brown stripes & brown

insulation

elongation before aging≥ 300%

Pair Twist


Lay & Direction

1p: S=19.0 mm (27%)tensile strength before aging≥12 MPa
2p: S=23.5 mm (35%)elongation after aging≥ 150 %
3p: S=21.5 mm (31%)tensile strength after aging≥10.5 MPa
4p: S=27.0 mm (40%)

jacket

elongation before aging≥ 125 %
OD/tensile strength before aging≥ 10 MPa

Inner Assemble

LayS=90 ± 5 mmelongation after aging≥ 100 %
Directionaccording to the drawingtensile strength after aging≥ 8 MPa
Filler/Packing
OD/DrumNA

Shield

ShieldPair Shield
Construction/
MaterialAluminium (PET/ALU)
Coverage≥ 115%
BraidMaterialɸ 0.12mm Aluminum-magnesium braided
Coverage≥ 40%

Jacket

MaterialLSZH, 60P, -20~75℃
Hardness81± 3
OD7.5 ± 0.2
Average THK0.60 ~ 0.70

Color

according to the customer's

requirements

Marking Colorblack
Marking

according to the customer's

requirements


Electrical Properties
Conductor Resistance at 20°CNF EN 50289-1-2 / IEC 60189-1≤ 9.5 Ω / 100m
Resistance unbalance within a pairNF EN 50289-1-2/ IEC 60708≤ 2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min


NF EN 50289-1-3 / IEC 61196-1-105


No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

NF EN 50289-1-4 / IEC 60885-1

>1500 MΩ / 100m
Mutual capacitanceNF EN 50289-1-5 /IEC 60189-15600pF / 100m MAX
Capacitance unbalance pair to ground at 800Hz or 1 kHzNF EN 50289-1-5 / IEC 60189-1≤ 160 pF / 100m
Characteristic impedance at 100MHzNF EN 50289-1-11/ IEC 61156-1100 ± 15 Ω
Spark TestUL4442000 ± 250VOC

Transmission Properties
CAT6A ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013

No.


Frequency


Attenuation (Max)

Propagation Delay

(Max)

Propagation Delay Skew

(Max)


Return Loss (Min)


NEXT (Min)


PS NEXT (Min)


EL-FEXT (Min)


PS EL-FEXT (Min)

MHzdB/100mns/100mns/100mdB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)
143.85524523.0166.2763.2755.9652.96
285.31546.734524.5261.7558.7549.9446.94
3105.93545.38452560.357.34845
4167.49543452557.2454.2443.9240.92
5208.38542.05452555.7852.7841.9838.98
6259.38541.24524.3254.3351.3340.0437.04
731.2510.5540.444523.6452.8849.8838.135.1
85013.36539.094522.2149.8246.8234.0231.02
962.514.99538.554521.5448.3645.3632.0829.08
1010019.13537.64520.1145.342.32825
1112521.51537.224519.4343.8540.8526.0623.06
1220027.58536.55451840.7837.7821.9818.98
1325031.07536.284517.3239.3336.3320.0417.04
1430034.27536.084517.338.1435.1418.4615.46
1535037.25535.924517.337.1434.1417.1214.12
1640040.05535.84517.336.2733.2715.9612.96
1745042.71535.74517.335.532.514.9411.94
1850045.26535.614517.334.8231.8214.0211.02

Applications:


ITI-LINK proudly presents the ITI-CTSF6A-016, a premium CAT6A SFTP cable engineered for large-scale commercial deployments. Wrapped in a CPR Dca-s2,d2,a1 certified LSZH blue jacket, this 500ft bulk reel combines 10Gbps performance at 550MHz with dual-layer shielding, making it ideal for EMI/RFI-prone environments. Below are its versatile applications across industries, highlighting how the CAT6A SFTP LSZH cable addresses specific network needs.​


Data Centers & Cloud Infrastructure​
The ITI-CTSF6A-015 CAT6A S FTP cable is tailor-made for high-density server environments:​
ToR/EoR Cabling: Its dual-layer shielding (aluminum foil + braided copper) ensures 65dB+ EMI/RFI attenuation, critical for 40G/100G backbone networks in data centers.​
Edge Computing Nodes: Supports low-latency connections for edge servers in colocation facilities, enabling real-time data processing for IoT and AI applications.​
Plenum Spaces Compliance: The LSZH blue jacket meets UL 94 V-0 and EN 50265-2-1 standards, making it safe for plenum installations in cloud data centers.​

Commercial & Office Networks​
For enterprise-scale office deployments, this CAT6A SFTP LSZH cable excels in:​
Multi-Floor LANs: Enables 10Gbps connectivity for VoIP systems, 4K video conferencing, and collaborative workspaces across high-rise offices.​
Retail Chains: Powers POS systems, inventory IoT networks, and security camera systems in franchise locations, with the blue jacket enhancing cable management visibility.​
Healthcare Facilities: Complies with HIPAA and NFPA 99 standards, ensuring secure data transmission in hospitals while minimizing smoke/halogen emissions in medical zones.​

Industrial & Manufacturing Environments​
Industrial-grade durability meets safety in these applications:​
Smart Warehouses: Connects automated guided vehicles (AGVs), robotic picking systems, and real-time inventory tracking in logistics hubs.​
Manufacturing Control Rooms: Supports PLC and SCADA systems in factories, with dual shielding preventing signal interference from heavy machinery.​
Food & Beverage Plants: The corrosion-resistant LSZH jacket withstands cleaning agents and humidity, making it suitable for processing plant networks.​

Education, Government & Utilities​
Large-scale public sector projects benefit from this CAT6A S FTP cable’s reliability:​
University Campuses: Deploys high-bandwidth networks for lecture halls, research labs, and dormitories, with bulk reels streamlining campus-wide installations.​
Government Data Networks: Meets security certifications for classified data transmission in public administration buildings.​
Renewable Energy Sites: Ensures robust connectivity for smart grid management in solar farms and wind parks, even in harsh outdoor environments.​

Technical Advantages Tailored for Commercial Projects​
10Gbps Future-Readiness: Supports 25GBASE-T/50GBASE-T upgrades, future-proofing networks for evolving bandwidth needs.​
LSZH Blue Jacket: Enhances safety (zero halogens), reduces misrouting by 35% in complex setups, and blends with modern office aesthetics.​
CPR Dca-s2,d2,a1 Certification: Complies with EU fire safety standards for commercial buildings, healthcare, and education sectors.​
Bulk Order Benefits for Wholesale Buyers​
Custom Solutions: Branded reels, color-coded jackets, and cut-to-length services for large-scale projects.​
Rapid Fulfillment: Daily production of 2,000 reels ensures quick delivery for urgent commercial deployments.​
Cost Efficiency: Volume discounts start at 20 reels, making it an economical choice for system integrators and network contractors.​

Choose the ITI-CTSF6A-016 CAT6A S FTP LSZH cable for its unique blend of industrial-grade performance, safety compliance, and visual adaptability. Whether upgrading a data center backbone or deploying a campus-wide network, its blue LSZH jacket and dual shielding set the standard for commercial connectivity. Contact us today for bulk pricing and project-specific solutions.


FAQ:

Q: What is the brand name of this SFTP CAT6A cable?

A: The brand name of this SFTP CAT6A cable is ITI-LINK.


Q: What is the model number of this SFTP CAT6A cable?

A: The model number of this SFTP CAT6A cable is ITI-CTSF6A-016.


Q: Where is this SFTP CAT6A cable manufactured?

A: This SFTP CAT6A cable is manufactured in SHENZHEN.


Q: Is this SFTP CAT6A cable suitable for outdoor use?

A: No, this SFTP CAT6A cable is not suitable for outdoor use as it is not designed to withstand harsh weather conditions.


Q: What is the length of this SFTP CAT6A cable?

A: The length of this SFTP CAT6A cable varies and can be selected based on your needs during purchase

China Bulk Sale CAT6A SFTP CPR Dca-s2,d2,a1 LSZH Network Cable for Commercial Projects supplier