

Add to Cart
Ultrapure In-Line Heaters PFA Inline Chemical Heater For Aggressive
Acids & Chemicals are ideal for heating deionized water, acids, and
less aggressive process chemistries use in high-purity processes of
semiconductor, solar, MEMS manufacturing, and other industries
using high-purity fluids.
These heaters are designed for recirculation and point-of-use fluid
heating applications.
Their small footprints allow them to easily integrate into current
systems.
Available in 1-30 kW and various voltages.
We offers a variety of patented and uniquely-engineered ultra-pure precision heaters for heating various chemical and plating solutions, gases, solvents and deionized water.
Our award-winning engineers design and manufacture components from PFA, applied to patented PFA heating technology, that achieves a small mass with a large surface area, providing a faster heater response and a longer life at elevated temperatures.
Our extremely flexible high-output heating coils are capable of being fashioned into an almost endless variety of shapes and sizes.
The resulting heaters outlast competing products of lesser capability and are designed into a wide range of standard and customized products.
Heater | Patented coil |
---|---|
Wetted Surfaces | PTFE/PFA |
Sizes | 1 kW to 30 kW (dependent on customer voltage) |
Voltages | 200 VAC to 480 VAC, 1-ph and 3-ph (dependent on wattage) |
Temperature | Ambient to 95º C (203º F) |
Temperature Accuracy | ± 0.1º C |
Flow | 0.5 GPM (1.9 LPM) to 32 GPM (122 LPM) (dependent on model) |
Pressure | 60 PSIG @ 95º C |
Industries
Products For Ultra-High-Purity Heating | ||
Inline Heater | PFA Inline Heater | Inline Chemical Heater |
FAQ
What To Do If Your Shipment Is Damaged:
Leave the items, packing material, and carton “as is”. Notify your carrier’s local office and ask for immediate inspection of the carton and its content. After inspection has been made by the carrier, and you have received acknowledgment in writing as to the damage, please contact our Customer Service Department at +86-13560811662 for return authorization. If writing for return authorization, please indicate your purchase order number. We will repair or replace the merchandise depending on the extent of the damage. It is your responsibility to follow the above instructions, or the carrier will not honor any claims for damage. If there are any shortages or questions regarding this shipment, please notify us within ten (10) days.
Safety Precautions
Every effort has been made to insure that this unit will run with a minimum of user input or maintenance. However, there are still precautions to be taken whenever operating, performing maintenance, or servicing this unit. This unit makes use of heating elements and electrical components, both of which pose inherent burn, fire, and electrical shock hazards. These hazards can result in injury to personnel, plant, and/or process. Please note the following to aid in the operation of your unit and to decrease risk of the above mentioned hazards.
Precautions
• Carefully and completely read this and all accompanying literature to verify that you understand the functionality and features of this system. Please become familiar with the integral safeties and controls within this system, and know their function.
• Always disconnect electrical power prior to installing, servicing or replacing electric heating elements and/or assemblies.
• Electrical termination enclosures should be selected to match the application’s environment and be able to withstand worst-case failures, especially in hazardous locations