Product Details
Product Applications
- Heating systems in high - rise buildings that require zoning (new
construction).
- Heating systems in high - rise buildings that require zoning
(reconstruction).
- Central air - conditioning water systems in high - rise buildings
that require zoning.
- Heating systems in multi - story buildings located at the end of
the heat network, where the pressure difference between the supply
and return water is too small to ensure normal flow.
- Multi - story buildings located at the highest point within the
same heat network, where the topographic height difference is too
large.
1.Direct - connection Heat - supply Pipeline Network
- Direct - connection pipeline network, utilizing existing pressure
for energy - saving;
- Without additional equipment like heat exchangers, water tanks, and
make - up water devices, saving land and investment.
2.High - efficiency Water Pumps
- Variable - frequency operation;
- High - efficiency hydraulic model optimized by CFD design.
3.High Integration Degree
- Electromechanical integrated design reduces the floor space of the
equipment;
- Factory - prefabricated and modularly assembled, saving investment
and shortening the cycle.
4.Intelligent Management
- Whole - life - cycle intelligent management, comprehensive energy -
flow analysis and full - range energy control;
- Automatic operation, data collection, analysis, and control via the
Internet of Things, maximizing energy - saving and reducing
operating costs.
5.Low - resistance Valves
- Full - bore non - slamming low - resistance check valves;
- Full - bore quick - closing butterfly valves.
6.Low - resistance Corrosion - resistant Pipelines
- Cut by laser equipment and welded by robots, with smooth ports, low
resistance, and reliable welding quality;
- Made of well - known brand pipes or tubes, with anti - rust
treatment like passivation and electrolytic polishing to prevent
corrosion.
DFGZL Energy - saving and Cost - reducing
With the continuous increase in high - rise buildings in our
country, the heating hot - water pressure from municipal and heat -
exchange stations often fails to meet the demand. Traditional
heating units have complex systems, numerous equipment, high
maintenance costs, large initial investments, and occupy a lot of
space. In some cases, heat loss during heat exchange occurs, and
the heating standards for buildings may not be met. Increasing the
heat - exchange area or raising the network pressure would
significantly increase investment, but our DFGZL high - rise direct
- connection heating unit offers a solution.
This unit combines the high - zone heating system and low - zone
heating system in high - rise buildings directly. It overcomes many
technical drawbacks of traditional high - rise building heating
equipment. Without dedicated high - zone boilers, water tanks, and
it directly pressurizes the heat - supply water from coal - fired
sources to the high zone, avoiding a large amount of heat loss in
the heat - exchanger system. It features a simple structure, low
equipment investment, high heat efficiency, and fully automatic
operation. This heating system is widely applied in high - rise
building heating.
01 High - efficiency Water Pumps- The unit can automatically activate pumps for variable - frequency
operation based on the system flow demand, making the system more
energy - efficient.
- It has a high - efficiency hydraulic model optimized by CFD
(Computational Fluid Dynamics) for hydraulic model optimization.
02 Low - resistance Pipe Valves- Full - bore non - slamming low - resistance check valves.
- Laser - cut materials and robot welding ensure smooth valve ports
and low resistance.
- Full - bore quick - closing butterfly valves.
03 Direct - connection to Heat - supply Company Pipeline Network,
Pressure Boosting, Small Footprint- Without dedicated boilers, water tanks, heat exchangers, pressure -
reducing valves, expansion tanks, and water treatment systems, the
system is simple and the investment cost is low.
- Users can directly use the high - temperature network water for
heating, eliminating the heat - exchange process, improving heat -
energy utilization, and coal - burning temperature. Equipped with
filters to ensure the quality of the supplied water and prevent
water - inlet network blockage, thus significantly enhancing the
heating effect.
- The unit operates in a variable - frequency mode, making full use
of the external network water pressure, resulting in significant
energy savings.
| |
DFGZL High Reliability- Sound quality management, after - sales service system, and product
craftsmanship
01 High - standard Hardware- Coating thickness measurement ensures the equipment is corrosion -
resistant and has a long lifespan.
- The equipped frequency converters feature a high protection level
(IP55), are dust - proof, have thickened PCB coatings, and exhibit
high reliability.
- Equipped with imported brand components.
- Equipped with imported brand programmable logic controllers.
02 Sound Quality Management and After - sales Service System- The company has an IoT - Net certificate and a CTEAS certificate.
- Based on its quality management and after - sales service system,
the company conducts full - process quality control over four major
processes: resource management, management responsibility, product
realization, and measurement, analysis, and improvement. It
promotes product standardization and institutionalization, ensuring
product reliability and the timeliness of after - sales service.
03 Mature Product Craftsmanship- Manufactured using robots and numerically - controlled equipment,
surpassing traditional welding, cutting, and bending techniques,
ensuring product quality consistency and stability.
| |
Working Environment
- Power supply: 380V×(100±5)%, three - phase five - wire system;
- Ambient temperature: 4°C ~ +40°C (appropriate measures must be
taken if beyond this range);
- Relative air humidity: 20% ~ 90% (at 20°C), no condensation;
- Installation site should be free of conductive dust, gases that can
corrode metals and damage insulation, and areas with explosion
hazards;
- Altitude should not exceed 1000m. When it exceeds, control
components should be adjusted accordingly.
Selection of the Unit
Selection of the Pressure - boosting Circulating Pump:
Determine parameters such as the model of the pressure - boosting
circulating pump and the motor power based on the above - mentioned
head and flow rate.
Company Profile
. Located in Tianjin, China, Tianjin Shiny-Metals Technologyco.,
Ltd. is a professional company that specializes in the research and
development, design, production, sales, trade, and service of
pumps. Our products are exported to more than 40 countries and
regions, continuously building our global brand reputation. We
offer a wide range of pumps, including centrifugal pumps, axial
flow pumps, jet pumps, submersible pumps, deep-well submersible
pumps, and swimming pool pumps, with over 500 specifications
available. Our company has obtained the ISO 9001 certification from
the International Organization for Standardization (CQC). In
addition, our civilian motors have undergone product evaluation for
CCC China mandatory certification. We have also received
certifications such as CE, EMC, GS, RoHS, EAC, SASO, and ST. Our
company is dedicated to meeting customer needs with high-quality
products, reasonable prices, and exceptional pre-sales, in-sales,
and after-sales services. We adhere to the management principles of
"quality first, customer first, and reputation-based" and are
committed to providing global customers with the best solutions for
water pumps and water treatment systems, improving their quality of
life. Our goal is to make the world a better place through water,
and we strive to make water even better.