Add to Cart
UPS Uninterruptible Power Supply Aging Test Cabinet Manufacturer
Performance parameters
Category | Project | Content |
System | System architecture | One control cabinet + two load cabinets |
Total volume dimension | 4980*880*2050mm | |
Total land area | 4980*1800mm(Including the operation area) | |
Total input voltage | Three-phase five-wire 380Vac (rated) | |
Total input current | 130A*2 | |
Total input power | 66kW*2 | |
Application ambient temperature | 0-40℃ | |
Application environment humidity | 0-95% | |
Fire protection requirements | The material complies with UL 94V0 grade | |
Environmental protection requirements | The materials comply with Rohs and WEEE requirements | |
Safety requirements | It complies with the design requirements of the IEC62368international standard | |
Power cabinet | Number of units/cabinets | 8 bits per cabinet |
Input power of aged products | 6.6kW/bit | |
Input voltage of aged products | 220Vac/single phase | |
Input current of aged products | 32A/bit | |
Output power of aged products | 6kW/bit | |
Output voltage of aged products | 220Vac | |
Output current of aged products | 30A/bit | |
Type of AC connector | Anderson 50A | |
Signal connector type | RJ45(net opening) | |
Input power | 53kW | |
Feedback power | 42kW | |
Volume dimension | 2050*800*2050mm | |
Air duct direction in the product area | Forward wind, upward wind | |
Heat dissipation method | Air-cooled | |
Material | Cold-rolled sheet | |
Monitoring software | Display operation information | Input voltage, current, power, output voltage (load module communication or product communication) |
Display status information | Notconnected/Emptyposition/Qualified/Undervoltage/ undercurrent/Overvoltage/Overcurrent/No output/protection | |
Display accuracy | ±(1%+0.2%FS) | |
Control accuracy | ±(1%+0.2%FS) | |
Poor alarm mode | Sound and light alarm | |
Report format | CSV format | |
Statistical information | Yield rate /CPK/ time distribution | |
MES connection | Support | |
Scanning speed | 5S | |
Control cabinet | Output power of aged products | 5kW |
Control system | Window 10 | |
Display medium | Computers and monitors | |
Control medium | Mouse, keyboard | |
Communication method | Network cable | |
Protection type | Overcurrent, leakage, over-temperature, smoke detection, emergency stop | |
Alarm mode | Sound and light alarm, remote network | |
Heat dissipation type | Air-cooled | |
Maintenance mode | Post-maintenance | |
Volume dimension | 880*860*2050mm |
Architecture diagram