IFM Pressure sensor for pneumatics PQ7834 PQ-010-RHR18-QFPKG/AS/

Brand Name:IFM
Model Number:PQ7834
Minimum Order Quantity:1
Delivery Time:Negotiable
Payment Terms:T/T
Place of Origin:Germany
Contact Now

Add to Cart

Verified Supplier
Location: Hong kong China
Address: RM 509, 5/F, THE CLOUD, 111,TUNG CHAU STREET, TAI KOKTSUI, KOWLOON,HONG KONG
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

IFM Pressure sensor for pneumatics PQ7834 PQ-010-RHR18-QFPKG/AS/

Reliable monitoring of the system pressure in pneumatics and in compressed air systems

Very high overpressure and vacuum resistance

Clearly visible slanted LED display

Red/green display for clear identification of the acceptable range

Two switching outputs, one of which can be configured as diagnostic output


Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range-1...10 bar-15...145 psi-30...296 inHg-100...1000 kPa
Process connectionthreaded connection G 1/8 Internal thread

Application

Systemgold-plated contacts
Applicationfor industrial applications
Mediacompressed air
Conditionally suitable forother media on request
Medium temperature[°C]0...60
Min. bursting pressure30 bar435 psi886 inHg3000 kPa
Pressure rating20 bar290 psi591 inHg2000 kPa
Vacuum resistance-1000 mbar-0.1 MPa
Type of pressurerelative pressure; vacuum

Electrical data

Operating voltage[V]18...32 DC; (to SELV/PELV)
Current consumption[mA]< 50
Min. insulation resistance[MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Overvoltage protectionyes; (< 40 V)
Power-on delay time[s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal
Electrical designPNP
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Max. voltage drop switching output DC[V]2
Permanent current rating of switching output DC[mA]100
Switching frequency DC[Hz]< 200
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)

Measuring/setting range

Measuring range-1...10 bar-15...145 psi-30...296 inHg-100...1000 kPa
Set point SP-0.9...10 bar-13...145 psi-26...296 inHg-90...1000 kPa
Reset point rP-0.95...9.95 bar-14...144 psi-28...294 inHg-95...995 kPa
In steps of0.05 bar1 psi2 inHg5 kPa

Accuracy / deviations

Switch point accuracy[% of the span]< ± 0,5
Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span]< ± 0,25
Long-term stability[% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K]0,2; (0...60 °C)
Temperature coefficient span[% of the span / 10 K]0,2; (0...60 °C)

Reaction times

Response time[ms]< 2.5
Delay time programmable dS, dr[s]0; 0,002...5

Software / programming

Parameter setting optionshysteresis / window; normally open / closed; Diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit

Operating conditions

Ambient temperature[°C]0...70
Storage temperature[°C]-25...85
ProtectionIP 65

Tests / approvals

EMCEN 61000-4-2 ESD4 kV CD / 8 kV ADEN 61000-4-3 HF radiated10 V/mEN 61000-4-4 Burst2 kVEN 61000-4-5 Surge0,5/1 kVEN 61000-4-6 HF conducted10 V
Shock resistanceDIN IEC 68-2-2750 g (11 ms)
Vibration resistanceDIN IEC 68-2-620 g (10...2000 Hz)
MTTF[years]455
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g]84.5
Housingrectangular
Dimensions[mm]42 x 30 x 32
MaterialPBT; FKM; polyester
Materials (wetted parts)brass; FKM; silicon (coated); PBT
Min. pressure cycles50 million
Process connectionthreaded connection G 1/8 Internal thread




China IFM Pressure sensor for pneumatics PQ7834 PQ-010-RHR18-QFPKG/AS/ supplier

IFM Pressure sensor for pneumatics PQ7834 PQ-010-RHR18-QFPKG/AS/

Inquiry Cart 0