Integrated UPS Data Center All In One Smart Power Distribution System

Brand Name:kimoems or OEM
Certification:CE
Model Number:Refer to Parameters
Minimum Order Quantity:1pc
Payment Terms:T/T
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Building 3, Tuoji Park, No.691, Chang jiang West Road, Shushan District, Hefei, Anhui Province
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

Integrated UPS-data Center All-in-one Smart Power Distribution System

Equiped Rack-mounted modular UPS-25/30k power module

Product Introduction

The total input circuit breaker capacity is 630A,UPS input and output circuit breaker capacity >400A/3P;Output specifications are not less than:IT powerdistribution 2*24 channels 40A/1P, air conditioning powerdistribution 8*63A/3P, micro module internal lightingpower distribution 3*10A/1P
Power module: 180k +1 redundancy
Local single-screen management of power distributionUPS, battery and other information
All open spaces are arranged on one side
630A/3P circuit breaker can be replaced with 400A/ATS

Application Fields

This system is widely used in small and medium-sized data centers, edge DCs, and other scenarios without independent power distribution rooms. It is applicable to various industries such as finance, government, telecommunications, education, healthcare, and manufacturing.
Parameters
ModelKM0400A380-150KM0630A380-180
Rated Input Voltage380/400/415Vac,50/60Hz,3ph+N+PE380/400/415Vac,50/60Hz,3ph+N+PE
Input Voltage Range304-478VAC(line voltage) full load; 304-228VAC(line voltage) linear reduction from 100% to 75% loadSame as KM0400A380-150
Input Frequency Range40Hz-70Hz40Hz-70Hz
Input Power FactorFull load >0.99, half load >0.98Full load >0.99, half load >0.98
Rated Output Voltage380/400/415Vac,50/60Hz,3ph+N+PE380/400/415Vac,50/60Hz,3ph+N+PE
Power Factor11
Load Maximum Peak Factor3:013:01
System Efficiency96% (linear load)96% (linear load)
Module Current Sharing Index≤2%≤2%
Wiring MethodDefault upper inlet/outlet, supports lower outletDefault upper inlet/outlet, supports lower outlet
AC Lightning ProtectionC-level lightning protectionC-level lightning protection
Rated Capacity25-150kVA Power module quantity≤7(6+1), single module capacity25kVA/25kW30-180kVA, Power module quantity≤7(6+1), single module capacity30kVA/30kW
Input MethodMCCB or ATSMCCB or ATS
Mains UPS Power SupplyMains:400A+UPS:3*250AMains:630A+UPS:3*400A
IT Power Supply32A24240A242
Air Conditioner Power Supply63A*863A*8
Lighting Power Supply10A*310A*3
Operating Temperature Range0-400-40
Storage Temperature-40-70 (without battery)-40-70 (without battery)
Relative Humidity5-95% no condensation5-95% no condensation
Altitude0-1000m (above 1000m refer to IEC62040-3 standard derating)0-1000m (above 1000m refer to IEC62040-3 standard derating)
Protection RatingIP20IP20
NoiseAt 25, 1m front of equipment, 1/2 height: 50% load: <52dB; 100% load: <71dBAt 25, 1m front of equipment, 1/2 height: 50% load: <52dB; 100% load: <71dB
External Dimensions W×D×H600mm×1100/1200mm×2000mm600mm×1100/1200mm×2000mm