Online Heavy Metal Monitor in Water Hexavalent Chromium Analyzer
>>Application

This method is applicable to wastewater with hexavalent chromium concentrations within the range of 0-20 mg/L.


>>Technical parameters

1. Measurement Method: Diphenylcarbazide spectrophotometric detection
2. Measurement Range: 0-5 mg/L, OEM 0-20mg/L
3. Accuracy: ≤±10%
4. Repeatability: ≤±5%
5. Measurement Cycle: Minimum cycle is 30 minutes; color development time can be adjusted flexibly between 5-30 min based on environmental conditions.
6. Sampling Cycle: Adjustable time interval (10-9999 min) or on-the-hour measurement mode.
7. Calibration Cycle: Adjustable at any interval from 1-99 days.
8. Maintenance Cycle: ≥168 hours, with each maintenance lasting ~1 hour.
9. Reagent Consumption: <0.50 CNY per sample.
10. Outputs: RS-232, 4mA-20mA, RS-485.
11. Environmental Requirements: Temperature-controlled indoor environment (recommended: 5-40°C); humidity 45%-85%.
12. Power Supply: AC 220±10% V, 50±1% Hz, 5A.
13. Dimensions: Height 1500 × Width 500 × Depth 450 mm.
14. Additional Features:

  • Data retention during abnormal alarms or power outages.
  • Touchscreen display and command input.
  • Automatic discharge of residual reactants and resumption of operation after power restoration or system reset.

>>Feature

Unique Design: This product features a distinctive design that ensures lower failure rates, reduced maintenance requirements, minimal reagent consumption, and higher cost-effectiveness compared to similar products.

  1. Selector Valve Assembly:

    • Enables flexible reagent sampling timing and diverse channel configurations.
    • Minimizes dead volume for easy maintenance and extended service life.
  2. Micro-Dosing Unit:

    • Utilizes a visual photoelectric system for precise reagent measurement, eliminating quantitative errors caused by peristaltic pump tube wear.
    • Achieves accurate micro-dosing with 0.7 mL per dose, significantly reducing reagent usage.
  3. Sample Introduction Unit:

    • Employs a peristaltic pump with negative pressure suction, creating an air buffer zone between reagents and the pump tube to prevent corrosion.
    • Simplifies and enhances flexibility in reagent mixing.
  4. Sealed Digestion Unit:

    • Operates under high-temperature and high-pressure conditions to accelerate reactions.
    • Eliminates corrosion risks from volatile gases in open systems.
  5. Reagent Tubing:

    • Uses imported modified PTFE (polytetrafluoroethylene) transparent tubing with an inner diameter >1.5 mm to minimize clogging by particulate matter in water samples.

>>Analytical Principle

After acid digestion, the water sample is mixed with a conditioning agent. Under acidic conditions in the presence of a chromogenic agent (typically 1,5-diphenylcarbazide), hexavalent chromium [Cr(VI)] reacts to form a violet-red chelate complex (λ<sub>max</sub> = 540 nm). The spectrophotometric analyzer quantifies Cr(VI) concentration by measuring absorbance changes proportional to the Beer-Lambert law. The chromogenic complex concentration directly correlates with the original Cr(VI) content in the sample.