The AG-TPF07 Temperature-Pressure-Flow Monitor consists of a Pitot tube, resistance temperature detector (RTD), differential/absolute pressure sensor array, blowback unit, and signal control processor. Designed specifically for high-dust, high-temperature, high-humidity, and highly corrosive environments in emission flue gas monitoring, this integrated system provides real-time continuous measurement of flue gas velocity, dynamic pressure, static pressure, and temperature, suitable for monitoring gas flow velocity, pressure, temperature, and volumetric flow rate. The AG-TPF07 employs the Pitot tube principle to measure flue gas velocity. By using the Pitot tube, pressure sensors, and temperature sensors to detect the dynamic pressure, static pressure, and temperature of the flue gas, these parameters correlate with the gas flow velocity, enabling quantitative determination of the emission gas velocity.

>>Feature
  1. Real-time measurement of flue gas velocity, static pressure, and temperature, with three-channel two-wire loop 4-20mA analog output.
  2. Low starting flow velocity: 1 m/s.
  3. LCD display for real-time data and signal visualization, enabling direct readouts and simplified calibration.
  4. High measurement accuracy, robust reliability, and continuous 24/7 operation capability.
  5. Split-type design with telescopically adjustable Pitot tube for flexible installation.
  6. Automatic/manual blowback control: Programmable purge intervals or external trigger compatibility (220V signal input) for particulate cleaning, integrating with existing PLC systems.
  7. Simplified installation wiring and minimal maintenance requirements.
  8. Compact footprint for space-constrained deployment.

>>Main technical parameters
RangeFlow Velocity: 0-30 m/s (Startup threshold: 2 m/s)
Pressure: ±2.5 kPa (gauge)
Temperature: 0-300°C
AccuracyFlow Velocity: ±1% F.S
Pressure: ±0.1% F.S
Temperature: ±3°C
ResolutionFlow Velocity: 0.01 m/s
Pressure: 0.01 kPa
Temperature: 0.1°C
Pressure sensorAG-TFP07-F: Silicon piezoresistive pressure sensor
Temperature sensorPT100
Sampling methodInsertion-type
Installation methodDN65 flange connection
Pitot tube length500, 800, 1100, 1500 mm (adjustable Pitot tube)
Working environmentAmbient Temperature: -25 to 65°C
Vibration: <1g acceleration
DisplayOLED screen (4-digit numeric display)
Power supply220 VAC ±10%, 50 Hz, 1A
Output
  1. Analog: 3-wire isolated 4-20 mA (load resistance <500 Ω)
  2. Digital: Modbus protocol, isolated RS485-2W (module required)