High Temperature Extraction Method CEMS Monitoring System For SO2 NO NO2 Fast Response Gas Analyzer

Brand Name:JUGE
Certification:IOS9001, CE
Model Number:AG-CEMS09
Minimum Order Quantity:1 Unit
Delivery Time:5-8 working days
Payment Terms:Online order,T/T
Contact Now

Add to Cart

Verified Supplier
Location: Nanjing China
Address: 2F, BLK A, TAIPING IND PARK, #219 JIANGJUN AVE, JIANGNING DISTRICT, NANJING, CHINA
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

High Temperature Extraction Method CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Gas Analyzer


>>Overview

It can monitor the real-time concentration of particulate matter and gaseous pollutants in exhaust gases from fixed pollution sources (such as boilers, industrial furnaces, incinerators, etc.), suitable for high-humidity, low-concentration environments.

CEMS typically consists of three main components: the gaseous pollutant monitoring unit (SO2, NO, NO), the flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), and the data acquisition and processing unit.

The sample gas passes through a high-temperature heating pipeline, is filtered by a two-stage dust filter, and directly enters the gas chamber in the analyzer. The gas chamber is placed inside a high-temperature box and connected via UV fiber optics to a UV differential analyzer for flue gas measurement.

>>Feature
1) Full-flow high-temperature extraction design, fast response time, accurate measurement, and minimal sulfur loss.
2) PLC control with adjustable parameters for complex operating conditions.
3) Fully intelligent system design with fault alarms and easy maintenance.
4) Fully modular design, allowing flexible expansion of monitoring factors.
5) Direct NO measurement, avoiding conversion loss and ensuring accurate results.

>>Main technical parameters
ProjectIndex
Gaseous pollutantSo2(0~200) mg/m3, the range can be customized
No(0~200) mg/m3, the range can be customized
No2(0~200) mg/m3, the range can be customized
O2(0~25)%
Repetitiveness≤2%
24h zero drift and range drift≤±2%f.s.
One-week zero-point drift and range drift≤±3%f.s.
Linear error≤±2%f.s.
Response time≤120s
Flue gas parameters
TemperatureMeasuring range(0~300) ºC, is customizable
Accuracy≤±3℃
PressureMeasuring range(-10~10)kpa
Accuracy≤0.5%
Velocity of flowMeasuring range(0~40) m/s, (0~2) kpa, the output is optional
Accuracy≤±2%
HumidityMeasuring range(0~40)vol%
Accuracy≤±2%

O2
Measuring range(0~25)%
Accuracy±2%
Data acquisition and processingData transmission module8-way analog input
1-channel rs485 communication interface
IPC6-way rs232 communication interface
Windows7 operating system
Operational softwareFlue gas emission monitoring software monitor
Power SupplyAc 220v,50hz,≤7kw


>>System composition

China High Temperature Extraction Method CEMS Monitoring System For SO2 NO NO2 Fast Response Gas Analyzer supplier

High Temperature Extraction Method CEMS Monitoring System For SO2 NO NO2 Fast Response Gas Analyzer

Inquiry Cart 0