SO2 NO NO2 Online Continuous Emission Monitoring System CEMS Online Gas Analyzer

Brand Name:JUGE
Certification:IOS9001, CE
Model Number:AG-CEMS07
Minimum Order Quantity:1 Unit
Delivery Time:5-8 working days
Payment Terms:Online order, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Nanjing China
Address: 2F, BLK A, TAIPING IND PARK, #219 JIANGJUN AVE, JIANGNING DISTRICT, NANJING, CHINA
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Online SO2 NO NO2 Continuous Emission Monitoring System CEMS Online Gas Analyzer


>>Overview

It can monitor the real-time concentration of particulate matter and gaseous pollutants in the flue gas emitted from stationary pollution sources (such as boilers, industrialfurnaces, incinerators, etc.), enabling supervision of production and emissions fromthe source.

CEMS (Continuous Emission Monitoring System) generally consists of three basic components: the gaseous pollutant monitoring unit (SO2, NO, NO2), the flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), and the data acquisition and processing unit.

The sample gas passes through a high-temperature heated pipeline, undergoes dustremoval via atwo-stage filter,and is dehumidified by a two-stage condensation system before directly entering the gas chamber of the analyzer. The gas chamber ishoused within the analyzer and connected to an ultraviolet differential analyzer via ultraviolet optical fibers, achieving accurate measurement of the flue gas.


>>Feature
1) Secondary condensation for rapid water removal, reducing SO2 loss.
2) Long-life UV xenon lamp with high wavelength resolution ensures low detection limits, minimal temperature drift, fast response time, and accurate measurements.
3) PLC-controlled with adjustable parameters to adapt to complex working conditions.
4) Intelligent system design with traceable fault alarms for easy maintenance and troubleshooting.
5) Fully modular design, enabling flexible expansion of monitoring factors.
6) Flexible configuration: Users can choose between an NO2-NO converter or direct NO measurement as required.

>>Main technical parameters
ProjectIndex
Gaseous pollutantSo2(0~200) mg/m3, the range can be customized
No(0~200) mg/m3, the range can be customized
No2(0~200) mg/m3, the range can be customized
O2(0~25)%
Repetitiveness≤2%
24h zero drift and range drift≤±2%f.s.
One-week zero-point drift and range drift≤±3%f.s.
Linear error≤±2%f.s.
Response time≤120s
Particulate matterMeasured range(0.5~15)m
Dust concentration range(0~10) mg/m3, the range can be customized
Accuracy≤±2%f.s./24h
Flue gas parametersTemperatureMeasuring range(0~300) ºC, is customizable
Accuracy
PressureMeasuring range(-10~10)kpa
Accuracy
Velocity of flowMeasuring range(0~40) m/s, (0~2) kpa, the output is optional
Accuracy
HumidityMeasuring range(0~40)vol%
Accuracy
Data acquisition and processingData transmission module8-way analog input
1-channel rs485 communication interface
IPC6-way rs232 communication interface
Windows7 operating system
Operational softwareFlue gas emission monitoring software monitor
Power SupplyAc 220v,50hz,≤7kw

>>System composition

China SO2 NO NO2 Online Continuous Emission Monitoring System CEMS Online Gas Analyzer supplier