Cusom Color High Voltage Cable 2XS(F)2Y A2XS(F)2Y 110kV Power Cable

Brand Name:Zhongdong
Certification:CCC,ISO,VED,TUV
Minimum Order Quantity:Negotiable
Delivery Time:7-30 days based on different qty
Payment Terms:,L/C,T/T
Place of Origin:Hebei,China
Contact Now

Add to Cart

Verified Supplier
Address: Room 801,Tower C,China Minmetals Financial & Trade Center,Xi'an International Trade & Logistics Park,Xi'an,Shaanxi,China
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

High Voltage Cable 2XS(F)2Y, A2XS(F)2Y 110kV Power Cable


Application


The 2XS(F)2Y cable is a type of power cable with specific design features, including cross-linked polyethylene (XLPE) insulation and a flame-retardant sheath. It is commonly used in the following applications:

  1. Industrial Power Distribution:Suitable for fixed installations in industrial plants, manufacturing facilities, or workshops due to its high mechanical strength and resistance to harsh environments.
  2. Public Infrastructure:Deployed in tunnels, subways, or underground utility networks where flame-retardant (F) properties are critical for fire safety compliance.
  3. Outdoor and Underground Installations:Resistant to moisture, chemicals, and UV radiation, making it ideal for direct burial, cable ducts, or outdoor power transmission systems.
  4. Renewable Energy Systems:Used in solar farms or wind power installations to connect distributed energy sources to grids, thanks to its durability and stable electrical performance.
  5. High-Temperature Environments:XLPE insulation allows operation at elevated temperatures (up to 90°C), suitable for applications near heat sources or in thermally demanding settings.
  6. Fire-Prone Areas: Flame-retardant sheath minimizes fire propagation risks, complying with safety standards for commercial buildings, hospitals, or densely populated zones.
  7. Railway and Transportation: Applied in railway signaling systems, station power grids, or traction networks where reliability and flame resistance are mandatory.


Construction


  1. Conductor: Copper or aluminum for good conductivity
  2. Insulation: XLPE (cross-linked polyethylene)
  3. Shielding: Metallic or semi-conductive layers to prevent electrical interference
  4. Armor (optional): Protects against mechanical damage in underground or harsh environments
  5. Outer Sheath: Provides environmental resistance and durability

Description


  1. Voltage Rating (Uo/U)(Um):64/110kV (123kV)
  2. Highest Network Voltage: 123kV
  3. Operating Temperature: -30°C to +90°C
  4. Short Circuit Temperature: +250°C
  5. Overload Temperature: +130°C

Specification


Parameter category

Parameter item

parameter values

configuration parameter

electric conductor

Material: copper core (cross-section range: 630~1600mm²)

External diameter of conductor

30.0~56.5mm (The larger the section, the increasing the outer diameter)

insulating course

Material: Cross-linked polyethylene (XLPE), thickness of 16.5±0.5mm

Conductor shielding layer

Thickness of 1.2mm (semi-conductive material)

insulation screen

Thickness of 1.0mm (semi-conductive material)

metallic sheath

Wrinkle aluminum sheath (2.0±0.2mm) (double galvanized steel strip, 0.5~0.8mm)

oversheath

Material: flame retardant polyvinyl chloride (PVC) or polyethylene (PE), thickness of 4.5±0.2mm

Electrical parameters

20 conductor DC resistance

0.0754~0.009 Ω / km (the larger the section, the lower the resistance)

90 conductor AC resistance

0.097~0.0142Ω/km

capacity value

134-282 p F/m (increased with increasing cross-section)

Power frequency pressure test

64 / 110kV (factory test)

Local discharge performance

At 5pC(1.5U under-voltage)

Mechanical and laying parameters

minimum bending radius

12 x cable outer diameter (armor layer requirement)

Allow working temperature

Long-term: 90, short circuit (within 5 seconds): 250

Laying ambient temperature

≥0

Vehicle flow reference

Flow rate in single return air

Section 630mm²: 1010A; section 1600mm²: 1690A (ambient temperature 40, soil thermal resistance 1.0m · / W)

Load flow rate of directly buried laying

Section 630mm²: about 800A; section 1600mm²: about 1300A (buried depth 1m, ground temperature 35)


China Cusom Color High Voltage Cable 2XS(F)2Y A2XS(F)2Y 110kV Power Cable supplier

Cusom Color High Voltage Cable 2XS(F)2Y A2XS(F)2Y 110kV Power Cable