6KW supports diesel generator split phase inverter


Charge and store electricity when the mains power is normal, and quickly invert the power supply after a power outage to ensure continuous electricity consumption. ​
Independent mains power and diesel generator interface, intelligent switching, stable and reliable power supply. ​
Hospitals, base stations, remote factories and mines are essential for emergency power supply. ​



KEY STRENGTHS
Support the construction of three-phase systems.
100A pass through.
AC solar to retrofit existing solar system(on-grid & off-grid).
Support 4-channel MPPT

Description

ModelR-6KUS
PV input data
Max. PV input power (kW)9
Max. PV input voltage (V)500
Min. PV input voltage (V)120
Start-up voltage (V)120
MPPT voltage range (without battery)(V)120~500
MPPT voltage range@full-load (V)150~430
Rated PV input voltage (V)310
No. of MPPT trackers4
No. of strings per MPPT tracker1/1/1/1
Max. input current per MPPT (A)14/14/14/14
Max. short-circuit current per MPPT (A)22/22/22/22

Battery input data
Battery typeLithium-ion / Lead-acid
Max. charge / discharge power (kW)6
Battery voltage range (V)40~60
Rated battery voltage (V)48
Max. charging / discharging current (A)135/135
Rated charge / discharge current (A)135/135
Battery charging strategySelf-adaption to BMS
BMS communicationCAN
AC output data (grid side)
Rated output power (kW)6
Max. apparent output power (kVA)6.6
Rated grid voltage( (V)110-127/208-240V split phase, 240V single phase
Grid voltage range (V)192~288
Rated grid frequency (Hz)60
Grid frequency range(Hz)55 to 65
Rated output current (A)25
Max. AC output current (A)27.5
Power factor0.8leading~0.8lagging
Max. grid passthrough current(A)100
THDi<3%
Grid type2L+N+PE
AC output data (load side)
Rated output power (kW)6
Max. apparent output power (kVA)6.6
Rated output voltage (L-N/L1-L2) (V)120/240
Rated output frequency (Hz)60
Rated output current (A)25
Max. AC output current (A)27.5
Peak output power110%,30s / 120%,10s / 150%,0.02s
Back-up switch time (ms)<20
THDu<2%
Protection
Supported protectionArc fault protection, PV reverse polarity protection, Anti-islanding protection, Ground fault protection
Leakage current protection, Insulation resistance detection, Backup output short circuit protection,
AC under-voltage protection, AC output over-current protection, AC over-voltage protection,
Surge protectionDC Type II / AC Type II
Over voltage categoryDC Type II / AC Type III
Certifications and standards
CertificatesFCC Part 15 Class B; UL1741SA all options, UL1699B, CSA 22.2; IEEE1547
General data
Ingress protectionIP65 / NEMA 3R
Operating temperature range (℃)-25~+60
CoolingFan cooling
Relative humidity0-95%
Operating altitude (m)0~4,000(Derating above 2,000 altitude)
Dimensions W*D*H (mm)450 x 820 x 240
Weight (kg)47
Topology (solar / battery)Transformerless / Transformer
Noise emission (dB)48
Display and communication