8KW three-phase inverter supporting high-power component loads - resunpower

8KW three-phase inverter supporting high-power component loads

Brand Name:RESUN
Model Number:R-8K-TH
Minimum Order Quantity:1pcs
Delivery Time:3-30days
Payment Terms:T/T
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: Floor A5-19, Huaqiang Science and Technology Ecological Park, Guangming District, Shenzhen
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

8KW three-phase inverter supporting high-power component loads

Support high-voltage power input and output to meet the needs of high-power power consumption scenarios. ​
Quickly respond to grid connections and achieve efficient and stable power transmission. ​
Specially designed for three-phase systems to ensure stable and reliable power output.



KEY STRENGTHS
Support full power discharge, automatic battery
Support 100% unbalanced load output.
charge and discharge management.
Support high power components.




Description

ModelR-8K-TH
PV input data
Max. PV input power (kW)12
Max. PV input voltage (V)1000
Min. PV input voltage (V)125
Start-up voltage (V)125
MPPT voltage range (V)180~850
MPPT voltage range@full-load (V)250~850
Rated PV input voltage (V)600
No. of MPPT trackers2
No. of strings per MPPT tracker1/1
Max. input current per MPPT (A)18/18
Max. short-circuit current per MPPT (A)25/25

Battery input data
Battery typeLithium-ion / Lead-acid
Max. charge / discharge power (kW)8.8
Battery voltage range (V)150-550
Battery voltage range@full-load (V)230-550
Max. charging / discharging current (A)50/50
Rated charge / discharge current (A)40/40
Battery charging strategySelf-adaption to BMS
BMS communicationCAN
AC output data (grid side)
Rated output power (kW)8
Max. apparent output power (kVA)8.8
Max. apparent input power(kVA)17.6
Rated grid voltage (V)220 / 380; 230 / 400
Grid voltage range (V)187~264.5
Grid input voltage (V)380; 400
Rated grid frequency (Hz)50/60
Grid frequency range(Hz)45-55 / 55-65
Rated output current (A)11.5
Max. AC output current (A)12.7
Power factor>0.99 (0.8 leading ~ 0.8 lagging)
THDi<3%
Grid type3L+N+PE
AC output data (back-up)
Rated output power (kW)8
Max. apparent output power (kVA)8.8
Rated output voltage (V)220 / 380; 230 / 400
Rated output frequency (Hz)50/60
Rated output current (A)11.5
Max. AC output current (A)12.7
Peak output power110%, 10mins; 120%, 1.25min; 150%, 20ms
Back-up switch time (ms)<10
THDu<2%
Protection
Supported protectionPV reverse polarity protection, Anti-islanding protection, Ground fault protection, Battery reverse protection,
Leakage current protection, Insulation resistance detection, Backup output short circuit protection,
AC under-voltage protection, AC output over-current protection, AC over-voltage protection
Over voltage categoryDC Type II / AC Type III
Certifications and standards
CertificatesIEC 61000-6-1/-2/-3/-4, IEC 61000-3-11, IEC61000-3-12; EN 62109-1, EN 62109-2; EN50549-1;
EN50549-10; EN50438; G98/G99:2022; VDE-AR-N 4105:2018; CEI 0-21:2022; C10/11; Rfg:2016/NC Rfg:2018/PTPiREE:2021;
NRS 097-2-1:2017; Hungary; NTS V2.1:2021-07&UNE217002:2020&UNE217001:2020; NA/EEA-NE7 – CH 2020;
OVE Directive R 25:2020, TOR Erzeuger Type A V1.2; TR3.3.1:2019;ANRE228; ANRE228; NA/EEA-NE7;
PPDS:2022 for A1&A2; RS 097-2-1 :2017; OVE Directive R 25:2020, TOR Erzeuger Type A V1.2; EIFS 2018:2
General data
Ingress protectionIP65
Operating temperature range (℃)-25~+60
CoolingNatural cooling
Relative humidity0-95%
Operating altitude (m)4000(>2000 power derating)
Dimensions W*D*H (mm)566 x 593.5 x 219.5
Weight (kg)32
Topology (solar / battery)Transformerless / Transformerless
Noise emission (dB)<45
Display and communication
DisplayMonochrome screen
CommunicationRS485,CAN,WiFi



China 8KW three-phase inverter supporting high-power component loads supplier

8KW three-phase inverter supporting high-power component loads

Inquiry Cart 0