150KW Built-in Isolation Transformer Power Conversion System for Impact Loads

Brand Name:RUSEN
Certification:IEC/EN 62109-1/-2, EN 62477-1, IEC/EN 61000-6-2/-6-4, EN 50549-1/-10, NRS 097-2-1:2017 ASGC, GB/T 34120, GB/T 34133, CGC-R46103:2018A, PTPIREE REV1.2: 2024 TYPE B
Model Number:PCS-A150-MG
Minimum Order Quantity:1pcs
Delivery Time:3-30days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: Floor A5-19, Huaqiang Science and Technology Ecological Park, Guangming District, Shenzhen
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

150KW Built-in Isolation Transformer Power Conversion System for Impact Loads


Adopting a compact architecture to achieve high-power integration within a unit volume, suitable for space limited scenarios, and balancing device miniaturization and high-power output requirements.
Dual backup of critical circuits and power supply, automatic switching in case of failure, coupled with intelligent thermal management system, ensures long-term stable operation without interruption.
Integrating efficient topology technology and energy optimization algorithms to reduce energy loss and improve energy utilization in scenarios such as energy storage grid connection and industrial power supply.



KEY STRENGTHS
Reactive power, active power adjustable.
Multiple working modes are available, which can be flexibly applied to various working scenarios.
Highest power density, maximum efficiency reach 97.5%.
Built-in isolation transformer, adapt to impact load.

Description

ModelPCS-A150-MG
DC(battery)
Voltage range (V)420~850
Max. current (A)405
AC(on-grid)
Max. output power (kW)165
Rated output power (kW)150
Rated voltage (V)400
Voltage range (V)320~460
Rated current (A)216
Max. output current (A)238
Rated frequency (Hz)50/60
Frequency range (Hz)45~55 / 55~65
THDi<3%
Power factor1leading~1lagging(settable)
Grid type3W+N+PE
AC(off-grid)
Rated voltage (V)400
THDu<1% Linear <5% nonlinear
Rated frequency (Hz)50/60
Overload capacity110% long-term
General data
Max. efficiency97.1%
Ingress protectionIP21
Noise emission (dB)<70
Operating temperature (℃)-30 ~ +55
CoolingForced air
Relative humidity0 ~95% non-condensing
Max. operating altitude (m)5,000(>3,000 derating)
Dimension W*D*H (mm)800*800*1,900
Weight(kg)1057
Self-consumption<0.5%
On/ off grid switchingAutomatic
Display and communication
DisplayLCD touch-screen
BMS communicationRS485, CAN
EMS communicationRS485, TCP/IP
CertificatesIEC/EN 62109-1/-2, EN 62477-1, IEC/EN 61000-6-2/-6-4, EN 50549-1/-10, NRS 097-2-1:2017
ASGC, GB/T 34120, GB/T 34133, CGC-R46103:2018A, PTPIREE REV1.2: 2024 TYPE B


China 150KW Built-in Isolation Transformer Power Conversion System for Impact Loads supplier

150KW Built-in Isolation Transformer Power Conversion System for Impact Loads