100KW Redundant Mode Isolated PCS Power Converter System - resunpower

100KW Redundant Mode Isolated PCS Power Converter System

Brand Name:RUSEN
Certification:IEC/EN 62109-1/-2, EN 62477-1, IEC/EN 61000-6-2/-6-4, EN 50549-1/-10, NRS 097-2-1:2017 ASGC, GB/T 34120, GB/T 34133, CGC-R46103:2018A, PTPIREE REV1.2: 2024 TYPE B
Model Number:PCS-A100-MG
Minimum Order Quantity:1pcs
Delivery Time:3-30days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: Floor A5-19, Huaqiang Science and Technology Ecological Park, Guangming District, Shenzhen
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details



Redundant mode isolation PCS accurately achieves AC/DC power conversion, ensuring efficient transmission and conversion of electrical energy in different power scenarios, and meeting diverse electricity needs. ​
Equipped with redundant mode, it automatically switches in case of faults, maintaining stable system operation and greatly reducing the risk of downtime caused by faults. ​
With excellent isolation performance, it effectively resists electromagnetic interference and is suitable for fields such as industrial production, data centers, and new energy generation that require strict power supply stability.


KEY STRENGTHS
Reactive power, active power adjustable.
Redundant design for auxiliary power supply.
Highest power density, maximum efficiency reach 97.5%.
Built-in isolation transformer, adapt to impact load.

Description

ModelPCS-A100-MG
DC(battery)
Voltage range (V)420~850
Max. current (A)270
AC(on-grid)
Max. output power (kW)110
Rated output power (kW)100
Rated voltage (V)400
Voltage range (V)320~460
Rated current (A)144
Max. output current (A)159
Rated frequency (Hz)50/60
Frequency range (Hz)45~55 / 55~65
THDi<3%
Power factor1leading~1lagging(settable)
Grid type3W+N+PE
AC(off-grid)
Rated voltage (V)400
THDu<1% Linear <5% nonlinear
Rated frequency (Hz)50/60
Overload capacity110% long-term
General data
Max. efficiency97.1%
Ingress protectionIP21
Noise emission (dB)<70
Operating temperature (℃)-30 ~ +55
CoolingForced air
Relative humidity0 ~95% non-condensing
Max. operating altitude (m)5,000(>3,000 derating)
Dimension W*D*H (mm)800*800*1,900
Weight(kg)936
Self-consumption<0.5%
On/ off grid switchingAutomatic
Display and communication
DisplayLCD touch-screen
BMS communicationRS485, CAN
EMS communicationRS485, TCP/IP
CertificatesIEC/EN 62109-1/-2, EN 62477-1, IEC/EN 61000-6-2/-6-4, EN 50549-1/-10, NRS 097-2-1:2017
ASGC, GB/T 34120, GB/T 34133, CGC-R46103:2018A, PTPIREE REV1.2: 2024 TYPE B