Add to Cart
Building Materials Flame Retardant Test ISO 5660 ASTM E 1354 Cone Calorimeter
ISO 5660 Cone Calorimeter Product introduction:
Heat release rate is a key performance indicator for evaluating the fire hazard of materials and products. As an internationally used test equipment, the cone calorimeter fully complies with the current major fire test standards and specifications (including ISO 5660 series, ASTM E1354, ASTM E1474, ASTM E1740, ASTM F1550, ASTM D6113, NFPA 264, CAN/ULC-S135 and BS 476-15, etc.). Its test principle is based on the basic thermochemical law of oxygen consumption method: there is a quantitative relationship between the heat released by material combustion and the oxygen consumption, and each kilogram of oxygen consumed corresponds to the release of approximately 13.1 megajoules of heat. During the test, the instrument accurately monitors a number of key parameters: real-time heat release rate, ignition time, oxygen concentration changes, carbon monoxide and carbon dioxide production rates, smoke generation and exhaust flow, etc. These data together constitute a complete evaluation system for the combustion characteristics of the material.
ISO 5660 Cone Calorimeter Test Standards:
• ISO 5660: Tests for reaction to fire - heat release rate, smoke
generation rate and mass loss rate
• ASTM E 1354: Standard test method for heat and visible smoke
release rate of materials
• BS 476 Pt.15: Testing of building materials and building
structures: – Methods for testing the heat release rate of products
• GB/T 16172-2007 Test method for heat release rate of building
materials
• NFPA 264
ISO 5660 Cone Calorimeter Structure Feature:
1. 19-inch standard cabinet integrated design, beautiful and easy
to operate
2. Conical heater - in a truncated cone, 230V, 5000W, heat output
is 0~120 kW/m2
3. 19" touch screen computer controls the entire test process
4. Automatic ignition system, automatic measurement of burning time
5. 3 K-type thermocouples and 3-phase PID temperature controller to
regulate temperature
6. Automatic split gate - protect the sample area before testing,
ensure the stability of initial quality measurement, and the
operator can have extra time to perform system inspection before
the test starts. For flammable samples, if there is no opening and
closing mechanism, it is easy to burn prematurely. This extra time
is very important for the operator
7. Sample holder - sample size 100mm x 100mm, thickness not
exceeding 50mm;
ISO 5660 Cone Calorimeter Specification:
Product name | Cone Calorimeter |
Standard | ISO 5660, ASTM D1354, BS 476-15 |
Size | 1,800 mm(W)*900 mm(D)*2,650 mm(H) |
Power | 220 V AC, 50/60 Hz, 30 A |
Weight | about 450 kg |
Manual | Supplied |
Exhaust | 50 l/s |
Utilities | Compressed Air, Methane, Nitrogen, CO/CO2 Mixing Gas, Dust
Collector |
Ignition system:
1. 10kV spark igniter, equipped with a safety stop device. The
igniter is automatically positioned by a lever connected to the
closing mechanism
2. The system automatically ignites; automatically times;
automatically shuts off the gas and flames out
Exhaust system:
1. It is composed of axial flow fan, stainless steel exhaust pipe,
diffusion plate, smoke hood, exhaust pipe, orifice flowmeter and
thermometer;
2. It is made of stainless steel to extend the service life.
Including hood, gas sample sampling needle, exhaust fan
Gas sampling system:
1. Including annular sampler, suction pump, particulate filter,
cold trap, exhaust valve, moisture filter and CO2 filter
2. Three-stage filter; filtration accuracy 0.5um
3. Refrigerated cold trap; compressor air conditioning
refrigeration system; control temperature 0~5℃
4. The sampler has 12 small holes opposite to the airflow
direction; built-in smoke filter; 685mm away from the smoke hood
Measurement system:
1. Paramagnetic oxygen analyzer, range 0-25%; imported British
Servomex oxygen sensor; linear response;
2. Use laser system to measure smoke density,
3. Use high-precision load-bearing sensor to measure the weight
change of the test material during the test process.
4. Temperature control system: PID temperature control, 3
thermocouples to measure the temperature of the radiation cone
User operating system:
1. Labwiew control system for experimental instruments, with
friendly interface, easy operation and precise control;
2. PID temperature control module is linked with power adjustment
module, and constant temperature adjustment is performed through
programmable controller control;
3. Signal acquisition and processing module is linked with air
volume circuit control module, and preset wind speed is
intelligently adjusted through programmable controller logic
calculation output;
4. The system provides query function. The system automatically
stores the number, temperature curve and data of the test sample
into the database in the system; and the number of the sample being
tested, test date, etc. can be entered for query.