Thermal Conductivity Analyzer (Hot Wire Method) Hot-Wire Thermal Property Tester

Brand Name:Lonroy
Certification:Includes Calibration Certification
Model Number:LRX-3
Minimum Order Quantity:1
Delivery Time:5-8 work days
Payment Terms:L/C,D/A,D/P,T/T,Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: A31, 11 Floor, No 1 Building, Minjian Jinrong Building, No 111 Guantai Road, Sanyuanli Community, Nancheng Street, Dongguan, Guangdong, China
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

Thermal Conductivity Analyzer (Hot Wire Method) Hot-Wire Thermal Property Tester

1.Description:

The LRX-3 thermal conductivity tester employs the transient hot wire method, including the cross-line method and the parallel-line method. It mainly measures the thermal conductivity, thermal diffusivity (heat diffusion coefficient), and specific heat capacity of solid and powdered materials at different temperatures. It features high precision, high resolution, and high reproducibility. It is controlled by a computer for automatic measurement. It is widely used in research institutions, quality inspection departments, factories, and mines for the measurement of material thermal conductivity.

This instrument is a new development based on the original LRX-2 model of our factory. It has improved measurement accuracy and reproducibility, and has a more reasonable structure and is easier to use. Model classification: LRX-3A mainly uses the cross hot wire method (the parallel line method can also be used to measure materials below 5w/mk); LRX-3B uses the parallel line method and can measure materials smaller than 25w/mk.

2.Standard

Reference standards for the instrument: GB/T 5990-2021 "Test Methods for Thermal Conductivity, Specific Heat Capacity and Thermal Diffusivity of Refractory Materials (Hot Wire Method)"; GB/T 17106-1997 "Test Method for Thermal Conductivity of Refractory Materials (Parallel Line Method)"; GB/T 11205-2009 "Determination of Thermal Conductivity of Rubber (Transient Hot Wire Method)"; GB/T 10297-2015 "Determination of Thermal Conductivity of Non-metallic Solid Materials (Hot Wire Method)" etc.

3.Configuration:

Including one LRX-3 test host, one software, one set of communication interface and data cable, one desktop computer, and one constant temperature test hotline. The constant temperature device and high-temperature line are optional items and will be configured according to the contract.

4.Technical Parameter

ParameterSpecification
Measurement Range
DRX-3A (Cross-Wire Method)0.015 ~ 2.0 W/(m·K)
DRX-3A (Parallel-Wire Method)0.015 ~ 5.0 W/(m·K)
DRX-3B (Parallel-Wire Method)0.015 ~ 25.0 W/(m·K)
Temperature RangeRoom temperature (standard). Optional systems available:
-40 to 120 °CRequires high/low temp chamber (Cu-Constantan wire)
RT to 1000 °CRequires resistance furnace (NiCr-NiSi or Pt-PtRh wire)
RT to 1300 °CRequires SiC rod furnace (Pt-PtRh wire)
RT to 1600 °CRequires MoSi₂ rod furnace (Pt-PtRh wire)
Accuracy< ±5.0 %
Sample Size

Two symmetrical blocks: ≥40mm×80mm×114mm (rectangular) OR

two semi-cylinders forming ≥Ø80mm×114mm cylinder.

Standard brick sizes (e.g., 230x110x65/75mm) recommended.

Custom sizes possible.

Temperature Resolution0.001 °C
Hot Wire Power Resolution
DRX-3A Current0.01 mA
DRX-3A Voltage0.1 mV
DRX-3B Current0.1 mA
DRX-3B Voltage0.1 mV
Power Supply220 V, 50 Hz, 500 W (Furnace controller requirements specified separately).
China Thermal Conductivity Analyzer (Hot Wire Method) Hot-Wire Thermal Property Tester supplier

Thermal Conductivity Analyzer (Hot Wire Method) Hot-Wire Thermal Property Tester

Inquiry Cart 0