Benchtop Spectral Transmission Instrument Spectral reflector
Spectral Chromatic Aberration Tester
1. Equipment introduction
This instrument can test the transmittance and color values of all
transparent or translucent flat plate objects, and can also test
the reflectance and color values of all transparent or opaque flat
plate objects, and can calculate excellent differences.
2. System features
1. Anti-ambient light interference
2. Can work continuously for a long time
3. Use computers to operate, with good scalability
4. The system core components have good stability, such as:
spectrometers, optical fibers, etc., are imported from original
products.
3. Equipment functions
1. It can output 380~1100 nanometer spectral transmittance and
spectral reflectance, and display the spectral curve.
2. The computer stores the D65 spectrum distribution and the A
light source spectrum distribution, which can automatically
calculate the visible light integral transmission ratio, the
visible light integral reflectance ratio and color value in the
environment of the D65 light source and the A light source, and
display it in real time on the screen.
3. The spectral transmittance curve and spectral reflectance curve
can be derived.
4. The diffuse and specular reflection of the sample can be tested.
5. The XYZ value of the sample, L*a*b*, etc. can be tested, and the
color difference value between different samples can be calculated.
6. The spectral wavelength interval is 5 nanometers by default, and
the wavelength interval can be adjusted to several levels of 5
nanometers as the base.
7. All data is saved in a separate file and can be exported to an
EXCEL file.
8. All test operations are carried out through the control
computer, and the test results can be saved, queried and printed
(there is no printer standard).
Wavelength range | 380-1100 nanometers |
Spectrum half height wide | 3-5 nanometers |
Wavelength accuracy | ±0.2 nanometers |
Spectral measurement interval | 1 nanometer |
Spectral storage interval | 5 nanometers |
Measurement speed | 0.5~2S adjustable |
Light source life | ≥2000 hours |
Measurement range | |
Transmission | 0~100% |
Reflectivity | 0~100% |
Measurement accuracy | 0.01% |
Stability | ±0.05% |
Repeatability | ≤0.1% |
Sample Requirements | |
Transmission | Not greater than 150*150mm |
Reflection | Sample size is not limited (large samples can only test edges) |
V. Usage environment
1. Ambient temperature: 0ºC~40ºC
2. Ambient humidity: <70%
3. Power supply method: AC220V5A
4. Avoid vibration