Add to Cart
The plastic pipe impact testing machine is suitable for impact
testing of various plastic pipes, plastic corrugated pipes, etc.,
to determine the required impact energy value for pipe failure, and
thus determine its impact strength. It meets the requirements of
GB/T14823.2 "Special Requirements for Electrical Installation
Conduits - Rigid Insulated Material Flat Conduits", JG/T3050
"Insulated Electrical Conduits and Accessories for Buildings", and
ZBG33008 "Polyvinyl Chloride Plastic Corrugated Wire Conduit".
This testing machine has a simple structure, easy operation,
intuitive and reliable, so its application is becoming increasingly
widespread.
1, Technical parameters
Impact energy: 6J
Impact height: 300mm
Heavy hammer weight: 1kg 2kg
End of interval steel block
Curvature radius: R300mm
Workbench type: flat or 120 ° V-type
Dimensions: Length x Width x Height: 300 x 140 x 670mm
Weight: Quantity: 20kg
2, Structural description
This testing machine consists of a base, a column, a guide rod, a
hammer, and a hook.
3, Operation
1. Place the testing machine steadily and place a rubber plate
under the base.
2. Wipe the testing machine clean and inject thin oil onto the
columns and guide rods.
3. Loosen the fastening screws, lift the guide rod, place the bell
on the hook, and then place the spacing steel block at the bottom
of the guide rod.
4. Place the sample on the cushion plate and make contact between
the spherical portion of the spacer steel block and the highest
point of the sample.
5. The guide rod is triangular with four scale lines from bottom to
top, representing heights of 0, 100, 200, and 300mm respectively.
After aligning the 0 mark with the upper part of the spacing steel
block, tighten the fastening screw.
6. Loosen the stop screw, move the crossbeam so that the bottom of
the bell is level with the desired height mark, and then tighten
the stop screw.
7. Press both hooks simultaneously to make the bell fall and impact
the specimen through the spaced steel blocks.
8. Lift the interval steel block, remove the sample, and observe
for cracks or damage.
9. After the experiment is completed, the bell, cushion plate,
spacing steel block and other parts should be wiped clean and
stored in a dry place. Do not impact without a sample.