Commercial: Showrooms, Supermarkets, Offices, Shopping Centers, Exhibition Halls, Restaurants, Logistic Centers, Multi-pupose Buildings
Public: Schools, Hospitals, Conference Halls, Laboratories, Museums, Stadiums

Paint shall be applied wherever possible by means of Airless spray. The paint material will be checked for conformity with shelf life restrictions, temperature and batch number. Mixing ratio, tip size and method of agitation shall be checked by QC to ensure adherence with the approved ITP and Paint Manufacturer's recommendations. Pot life will also be monitored once mixed. Only experienced spray applicators shall be used for the application of paint materials, and all shall wear appropriate PPE for the job.
3.2. Fillet weld leg size requirements:
| Form of fillet weld leg | K(fillet weld size) value | Note |
| Fillet weld without groove | K=(0.7~1)t and≤15mm | for most of the steel structure buildings |
| K=(0.5~0.6)t | for the strengthening ribs and other secondary members | |
| Fillet weld with groove(CJP and PJP) | K=t/4 and K≤10mm | for most of the steel structure buildings |
| K=t/2 and K≤10mm | important members(crane beams or connection between web plates and flange plates of similar members) |
| Parent metal thickness(t)(mm) | Minimum fillet weld size |
| t≤6 | 3(minimum value being 5 for crane beam) |
| 6 | 5 |
| 12 | 6 |
| t>20 | 8 |

3)Butt-welding on construction site:we require all the grooves should be bevelled on the upper rafter/column when it comes to bolt connection for web plates(see illustration 3). For the scenario of welding on web plates, please refer to the illustration 4.
3.3.2 Box column(groove on itself).See illustration 5
4. Welding groove form
Example: Shielded metal arch welding, complete joint penetration, butt welding, I shape groove, welding backing and single side weld would be marked MC-BI-BS1| Mark | Welding method | Penetration type |
| MC | Shielded metal arch welding | CJP-complete joint penetration |
| MP | PJP-partial joint penetration | |
| GC | Shielded arch welding Self-shielded arc welding | CJP-complete joint penetration |
| GP | PJP-partial joint penetration | |
| SC | Submerged arc welding | CJP-complete joint penetration |
| SP | PJP-partial joint penetration | |
| SL | Electroslag welding |
| Backing material type | Single/double side welding | ||
| Mark | Material | Mark | Single/double side welding |
| BS | Metal backing | 1 | Single side welding |
| BF | Other backing | 2 | Double side welding |
| Mark | Size of each part on groove |
| t | Thickness of welding plate(mm) |
| b | Groove root gap or gap between two members(mm) |
| h | Groove depth(mm) |
| p | Groove roof face(mm) |
| α | Groove angle(º) |
| Deflection | Type of structural members | Deflection Limitation | |
| Vertical Deflection | Portal frame rafter | Only support corrugated steel sheets roof and cold-formed section purlins | L/180 |
| If there is ceiling system | L/240 | ||
| If there is top running crane | L/400 | ||
| Mezzanine floor | Main beam | L/400 | |
| Secondary beam | L/250 | ||
| Purlins | Only support corrugated steel sheets roof | L/150 | |
| If there is ceiling system | L/240 | ||
| Corrugated roof steel sheet | L/150 | ||
| Lateral Deflection | Wall panel | L/100 | |
| Wind columns or wind truss structures | L/250 | ||
| Wall beam | Only support corrugated steel sheet wall | L/100 | |
| Support masonry wall | L/180 and ≤50mm | ||
| Material Specifications | ||||||
| No | Components | Specifications | Minimum yield strength | Applicable Design Code | ||
| 1 | Built -up (Plates) | GB/T1591-2008 | Fy = 34.5 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | ||
| 2 | Hot Rolled | Angles | GB/T3274-2007 | Fy = 23.5 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | |
Beams | GB/T11263-2010 | Fy = 23.5 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | |||
| 3 | Cold Form | Galvanized | GB/T 2518-2008 | Fy = 45.0 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | |
| 4 | Roof panel/Wall panel (Zinc) | GB/T12754-2006 | Fy = 34.5 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | ||
| 5 | Roof panel/Wall panel (Alu) | GB/T12754-2006 | Fy = 34.5 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | ||
| 6 | X-Bracing | Galvanized cable bracing | GB/T 700-2006 | Fu = 157 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | |
| 7 | Anchor bolts | GB/T 700-2006 | Fu = 40.0 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | ||
| 8 | High strength Bolts | GB/T 1228-2006 | Ft = 30.3 kN/cm2 Fu = 72 to 83 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | ||
| 9 | Machine Bolts | GB/T 1228-2006 | Ft = 13.8 kN/cm2 Fu = 41.0 kN/cm2 | CISA - China Iron & Steel Association - Latest Edition | ||