API 661 Type C Forced Draft Air Cooler with SA179 Fin Tubes for Boiler Feed Systems(BFW)

Brand Name:YUHONG
Certification:API 661, ASME SECTION VIII, PED 97/23/EC, EN13445, PED/2014/68/EU AD 2000
Model Number:Boiler Feed Water​
Minimum Order Quantity:1 Set
Delivery Time:45---150 DAYS
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo China
Address: 20 Floor, No.1 New World Building, NO.1018 Min'an Road, Yinzhou District, Ningbo, China, ZIP:315040
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

API 661 Type C Forced Draft Air Cooler with SA179 Fin Tubes for Boiler Feed Systems(BFW)


Forced Draft Type - Designed with tube bundles located on the discharge side of the fan.


Category​​Parameter​​Value/Description​
​Design Parameters​Design Temperature212°F (Max) / 49°F (Min)
Maximum Working Pressure (MWP)256 PSIG
Test Pressure333 PSIG
Flow ArrangementCrossflow
​Tube Bundle​Number of Tube Rows3
Number of Tube Passes6
Tube Dimensions (OD × BWG)5/8" OD × 16 BWG
Tubes per Section/Length212 tubes / 16 ft
Fin TypeHI-EFF (High Efficiency)
Fin MaterialAluminum (AL)
TurbulatorsAccelerators
​Material Specifications​Tube MaterialSA179 Carbon Steel
Nozzle MaterialSA350LF2 Alloy Steel
Header MaterialSA516-70 Carbon Steel
Plug MaterialSA350LF2 Alloy Steel
​Structural Details​Header TypeBox-Type
Nozzle Rating/Type150RF (150 lb. Raised Face Flanges)
Inlet Quantity/Size1 inlet / 3"
Outlet Module Quantity/Size1 outlet module / 3"
Corrosion Allowance0.0625 in
Grooved TubesheetDouble Grooved (DBL)
Plug TypeShoulder-Type
​Standards & Certifications​ASME Code & National BoardCompliant (YES)
CRN (Canadian Registration)AB/BC/SK
Additional SpecificationsAPI 661
​Controls & Accessories​LouversAutomatic (AUTO)
Protective ScreenIntegrated (INT)
PWM (Pulse Width Modulation)YES
​Inspection & NDT​Weld Inspection Requirements- ​​FX​​: 100% X-ray of all longitudinal seams, attachments, and nozzle butt welds.
- ​​SH​​: Spot X-ray (1 longitudinal seam & 1 end closure per header).
- ​​BX​​: 100% X-ray of all nozzle butt welds.
- ​​UT​​: 100% ultrasonic testing (UT) of all header seams, attachments, and nozzle butt welds.
- ​​H​​: Hardness testing.

Documents

  • ASME Code
  • Calculations
  • Data Reports
  • Nameplate
  • Inspection Check lists
  • Material Test Reports
  • Stress Relieve Charts
  • X-Ray Test Reports
  • Ultrasonic Test Reports
  • Dye Penetrate/Magnetic Particle Test Reports
  • Hydrostatic Test
  • Gauge Certificate
  • Hydrostatic Test
  • Certification Reports
  • Hardness Test Reports
  • Run Tests
  • Nozzle Load Calculations
  • Weld Maps/NDE Maps
  • Weld Procedures
  • Welder Log & Qualifications

​​Applications​​

  • Pre-cooling boiler feed water in ​​steam generation systems​​.
  • Process cooling in ​​oil & gas​​, ​​petrochemical​​, and ​​HVAC​​ industries.
  • Temperature control for ​​waste heat recovery​​ and ​​closed-loop systems​​.

China API 661 Type C Forced Draft Air Cooler with SA179 Fin Tubes for Boiler Feed Systems(BFW) supplier

API 661 Type C Forced Draft Air Cooler with SA179 Fin Tubes for Boiler Feed Systems(BFW)

Inquiry Cart 0