0-5V 4-20mA Loadcell Strain Gauge Dual Amplifier

Voltage: 10V


Output signal: 0-5V, 0-10V, 4-20mA (Optional)


Working temperature: -20~80


Working environment Humidity: 10%RH-90%RH


Precision: more than 0.1%F.S


0-5V 4-20mA Loadcell Strain Gauge Dual Amplifier




Load cell amplifier in aluminum alloy case / housing, display support




0-5V 4-20mA Loadcell Strain Gauge Dual Amplifier






Input signal
Cable connection mark

S (IN) +

S (IN) -

V (8V) -

V (GND) -

GND

Connection definition

Signal +

Signal -

Excitation voltage+

Excitation voltage -

Shield

Input signal
Cable connection mark

24V +

GND

I out

GND

Connection definition

Power supply+

Power supply -

Output signal

Shield



Note: Default setting of Excitation voltage is 10VDC, customer can adjust it as needed within 5V-15V.



Calibration:


First, with the whole system UNLOADED, adjust "ZERO" potentiometer to adjust the zero offset.


Measure the output voltage or current of signal output with multimeter, make sure the value is as close to


zero as possible. Otherwise zero variation will get bigger when we change gain factor.


1, Gain adjustment


Add known load to the system (recommend: 80%~100% of Full Scale), then calculate value of the


output voltage or current according to the ratio between loaded weight and the maximum capacity.


Get output value using a multimeter. Adjust amplifier gain by turning "FULL SCALE" potentiometer.


2, Review


Unload the system and measure zero output. Make sure that it is as close as possible to zero.


Add known load, check whether the output voltage or current is amplified as needed you wanted or not.


If not, repeat steps 1 and 2.


(Note: this section is for standard sensor amplifier parameters. For special requirements, please


contact our sales department)


Related Products

Note:

Below are weighing indicator / big display series, you can find other indicators in our web, if you cannot find it or you have special requirement, please send us e-mail snc at sensor-con doc com with model name or the special requirement you may have. We will come up with a solution for all of your indicator requirement.


FAQ

1. How to place an order?

Please provide us more details of what you want, such as: application, measurement range, output, accuracy, thread type, electric connector and other related parameters.

2. Does SNC offer any discount?

Yes, if you buy large QTY, please contact us, we will give you a big discount.

3. What terms of payment are available?

We accept T/T, L/C, Trade assurance, Western Union, Paypal, etc.

4.When will you arrange the production?

We will arrange the production immediately after receiving your payment.

5. How do you ensure good product quality?

We have a complete quality control system, all of our products are fully checked by IQC, OQC departments before shipping to our clients

6. Do you have warranty ?

Yes, we provide 1 year warranty for most of our products.


Factory & products

Packaging & Shipping

Sensor and Control weighing components/ products packaging pictures and warehouse.


Contact US

China Industrial Grade Loadcell Strain Gauge Dual Amplifier 0-5V 4-20mA Output Signal -20-80 C Operating Temperature supplier

Industrial Grade Loadcell Strain Gauge Dual Amplifier 0-5V 4-20mA Output Signal -20-80 C Operating Temperature

Inquiry Cart 0