Add to Cart
Introduction
This device is used to measure the cumulative flow and instantaneous flow of drinking water flowing through the tap water pipe. It is suitable for large-scale meter monitoring systems and secondary metering systems such as enterprises and universities.
Product features
1. Long service life.
2. Accurate reading: using infrared photoelectric direct reading technology, free from external interference.
2. Low power consumption: only connected to the power supply when collecting data, photoelectric passive direct reading code, the number is generated by the CPU and output through M-BUS or RS 485 BUS.
3. Unique structure: using dry detachable propeller mechanical structure, the counter is separated from the lower structure, and the reading remains clear permanently.
4. Easy maintenance: no need to disassemble from the pipeline, the replacement of the counter can be completed without stopping the water
Deployment conditions
1. Water temperature <50℃ (cold water meter)
2. Water temperature ≤90℃ (hot water meter)
3. Water pressure ≤1Mpa
4. The water meter cannot be immersed in water
Technical Parameters
Product model: | LXSY-50 ~ 300 |
Working voltage: | DC 36V |
Working current: | Meter Reading Current≤9 mA |
Static operating current≤1.3 mA | |
Communication rate: | 1200/ 2400/4800/9600bps |
Communication protocols: | DL/T645, CJ/T 188, Modbus, user customization or other industrial protocols |
Max communication distance: | 300m |
Accuracy rating: | Class 2 |
Flow Parameter
Model | Nominal | Q3/Q1 | Normal | Minimum reading | Maximum reading |
DN | m3/h | m3 | m3 | ||
LXRY-50 | 50 | 200 | 25 | 0.001 | 999,999 |
LXRY-65 | 65 | 200 | 40 | 0.001 | 999,999 |
LXRY-80 | 80 | 200 | 63 | 0.001 | 999,999 |
LXRY-100 | 100 | 200 | 100 | 0.001 | 999,999 |
LXRY-150 | 150 | 200 | 250 | 0.010 | 999,999 |
LXRY-200 | 200 | 200 | 400 | 0.010 | 999,999 |
LXRY-250 | 250 | 200 | 630 | 0.010 | 999,999 |
LXRY-300 | 300 | 200 | 1000 | 0.010 | 999,999 |
Dimension
Nominal diameter | Length | Width | Total height | Flange outer diameter | Bolt hole diameter | Bolt specification | Bolt quantity |
DN50 | 200 | 175 | 250 | 165 | 125 | M16 | 4 |
DN65 | 200 | 185 | 255 | 185 | 145 | M16 | 4 |
DN80 | 225 | 200 | 265 | 200 | 160 | M16 | 8 |
DN100 | 250 | 220 | 275 | 220 | 180 | M16 | 8 |
DN150 | 300 | 285 | 375 | 285 | 240 | M20 | 8 |
DN200 | 350 | 345 | 400 | 340 | 295 | M20 | 8 |
DN250 | 450 | 395 | 484 | 395 | 350 | M20 | 12 |
DN300 | 500 | 445 | 506 | 445 | 400 | M20 | 12 |
Flange connection is in accordance with GB4216.4-84 "10 bar grey cast iron pipe flange dimensions"