Add to Cart
SH103 Trace moisture tester adopts microcomputer automatic
control,According to the principle of Carl Fischer Coulomb
titration, compared with similar products at home and abroad, it
has the advantages of high sensitivity, fast electrolysis speed,
short balance time, accurate blank deduction, accurate and reliable
analysis results, etc.
Automatic Trace Moisture Tester
Trace Moisture Content Meter for Petroleum Products
Trace Moisture Meter ASTM D1744
Karl Fischer Trace Moisture Meter for Oils
Automatic Trace Moisture Meter Karl Fischer Moisture Meter
Karl Fischer Trace Moisture Meter for Various Oils
karlfisher apartus
It is a high quality analytical instrument for petroleum, chemical,
electric power, environmental protection, medicine, scientific
research and other departments.
The instrument adopts 32-bit embedded microprocessor as the main
control core, embedded in the mini-operating system;
The instrument comes with constant current detection, double
circuit balance titration function;
The electrolytic tank adopts waterproof and sealed design;
Support multiple calculation formulas, in line with the standard
GBT11133 and ASTMD 0304.
Technical parameters:
Carl, -- Hugh coulomb's law, to determination of trace moisture of
different materials, in line with the GB/T11133, this trace
moisture meter and the success of the application of this method,
and used the micro computer control, its fast analysis speed, high
precision, Chinese LCD color screen display, automatic printing,
double CPU design, blank current deducted automatically and
instrument fault self-diagnosis function, menu selection, and other
functions, to achieve a better operation and use, has simple
operation, automatic analysis instrument.
It is an instrument for oil moisture analysis
Display mode: color touch screen display
Titration method: microcomputer controlled electric titration
Output mode: automatic calculation, can output ug, PPM and %
Measurement range: 0.00001% to 100% as a percentage, 0.1 PPM to 1
million PPM as per PPM
Separation rate: 0.1ug
Electrolysis control: automatic electrolysis current tracking
control (up to 400mA)
Titration speed: 2.5mg/min(Max)
Sensitivity: 0.1ug-- 100g not more than 2%, converted to 0.3% above
1mg (excluding injection error)
Power: 60 va
Ambient temperature: 5-40~C
Operating ambient temperature: ≤ 90%
Required consumables: special Karl Fischer reagents, the instrument
itself with a set of reagents, after use can be purchased or
equipped by themselves.DL/T 915-05,GB 5832-1986
Specification
item | value |
Warranty | 1 year |
Type | SH103 Trace moisture meter |
Place of Origin | China |
Shandong | |
Model Number | SH103 |
Product name | Trace moisture titrator |
Titration method | Electricity titration(Coulomb analysis) |
Display | 5.6-inch color touch screen(LCD |
Electrolytic current control | 0~400mA automatic control |
Measuring range | 1ug~200mg |
Sensitive valve | 0.1ug H2O |
Precision | 10ug~1000ug±3ug 0.3% for 1mg above |
Printer: | Micro thermal printer |
Power supply | 220V±10%,50Hz |
Power | < 40W |
Overall dimension: 380 * 350 * 390 about 18kg |
Meet the following standards:
1, GB/T7600 "in operation transformer oil moisture content
determination method (coulomb method)"
2, GB6283 "chemical products in the determination of moisture
content Karl Fischer method (general method)"
3, SH/T0246 "determination of water content in light petroleum
products (electric quantity method)"
4, SH/T0255 "additives and lubricating oil containing additives
moisture determination method (electric quantity method)"
5, GB/T11133 "Determination of water content in liquid petroleum
products (Karl Fischer method)"
6, GB/T7380 "surfactant water content determination (Karl Fischer
method)"
7, GB10670 "industrial fluoromethane in the determination of trace
moisture in the Karl Fischer method"
GB/T606 General method for determination of moisture in chemical
reagents Karl Fischer method
9, GB/T8350 "denatured fuel ethanol"
10, GB/T8351 "automotive ethanol gasoline"
11, GB/T3776.1 "pesticide emulsifier moisture determination method"
12, GB/T6023 Determination of trace moisture in butadiene for
industrial use - Karl Fischer Coulomb method
13, GB/T3727 Industrial ethylene, propylene determination of trace
water
GB/T7376 Determination of trace moisture in fluoroalkanes for
industrial use
GB/T18619.1 Determination of water content in natural gas -- Karl
Fischer - Coulomb method
16, GB/T512 "grease moisture determination method"
17, GB/T1600 -- Determination of pesticide moisture
18, GB/T11146 "crude oil water content determination method (Karl
Fischer coulomb method)"
19, GB/T12717 "industrial acetate test method"
GB/T5074 Coking products -- Determination of moisture
1,1, 2-tetrafluoroethane (HFC-134a) for industrial use
1 PPM = 0.0001%
Packing list
S/N | Name | Quantity | Unit | remarks |
1 | SH103 automatic trace moisture meter | 1 | set | |
2 | Electrolyte (Karl Fischer reagent) | 1 | bottle | 500ml |
3 | Electrolytic cell | 1 | set | |
4 | Electrolytic electrode | 1 | piece | On the instrument |
5 | Measuring electrode | 1 | piece | On the instrument |
6 | Grinding plug | 1 | piece | On the instrument |
7 | Stir the son | 1 | set | |
8 | silicone pad | 10 | piece | |
9 | Color silicone | 1 | piece | |
10 | Vacuum grease | 1 | piece | |
11 | 25ulsampler | 1 | piece | |
12 | 1mlsampler | 1 | piece | |
13 | Enclosed the needle | 1 | piece | |
14 | power cord | 1 | piece | |
15 | fuse tube | 1 | piece | |
16 | packing list | 1 | copy | |
17 | Certificate of approval | 1 | copy |