Hamamatsu Microfocus X-Ray Source with 5μm Focal Spot

Brand Name:Hamamatsu
Model Number:L9181-02
Minimum Order Quantity:1
Payment Terms:T/T
Place of Origin:JAPAN
Place of Origin::JAPAN
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 5F,B3, Anda ElectronicsIndustrial Factory, HepingCommunity, Fuhai Street, BaoanDistrict, Shenzhen
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details
Hamamatsu X Ray Source 130 kV Microfocus X Ray Source for Metal Components with Focal Spot Size of 5 μm Product Description

X-RAY SOURCE 130 kV MICROFOCUS X-RAY SOURCE L9181-02


Applications
Non-destructive inspection
X-ray CT

Applicable objects:

  • Electronic component
  • Printed circuit board
  • Plastic component
  • Metal component
Key Features
  • Focal spot size: 5μm (at 4W) - Offers sharp and clear X-ray images even at high magnification
  • No high voltage cable connection required - High voltage power supply is integrated
  • External control via RS-232C interface
  • High power: Maximum output 39 W
Specifications
GENERAL
ParameterDescription/ValueUnit
X-ray tube voltage setting range0 to 130kV
X-ray tube current setting range0 to 300μA
X-ray tube voltage operational range40 to 130kV
X-ray tube current operational range10 to 300μA
Maximum outputSmall focus mode: 8 W
Middle focus mode: 16 W
Large focus mode: 39 W
W
X-ray focal spot size (Nominal value)Small focus mode: 8 (5μm at 4 W)
Middle focus mode: 20
Large focus mode: 40
μm
X-ray output window material/ThicknessBeryllium/0.2mm
X-ray beam angleApprox.45degree
Focus to object distance (FOD)Approx.13mm
Target materialTungsten
WeightApprox.10.5kg
Communication methodInterface: RS-232C (9-pin D-sub connector)
RATINGS
ParameterDescription/ValueUnit
Input voltage (DC)+24 (+2.4,-0)V
Power consumptionLess than 120W
Read outputContinuous rating--
Operating ambient temperature+10 to +40
Storage ambient temperature0 to +50
Operating and storage humidity20 to 85 (No condensation)%
REGULATION AND STANDARD
ParameterDescriptionUnit
RoHS DirectiveEN 50581 Category 9
EMCIEC/EN 61326-1
Emission limits: CISPR 11 Group 1 Class A
Immunity requirements: Table 2
CONTROL SOFTWARE
ParameterDescriptionUnit
Applicable PCPC/AT compatible
Applicable OSWindows® XP, 7
InterfaceRS-232C

NOTE:

① See the graph of the X-ray tube voltage/current operation range.

② Reference value: With 50% of maximum X-ray emission.

③ This weight includes the accessories of approx. 0.25 kg.

④ The control software is provided as a sample software for the purpose of MFX operation. The performance of the software is not guaranteed.