1. Product Brief Introduction:

HQ-LDE intelligent electromagnetic flowmeter consists of two parts: sensors and converters. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp. Widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management, water conservancy construction, river dredging and other fields for flow measurement. Small caliber electromagnetic flowmeter is suitable for measuring small flow liquids.

2. Product Features:

All digital processing, strong anti-interference ability, reliable measurement, high accuracy, and a flow measurement range of up to 150:1.
Ultra low EMI switching power supply, suitable for a wide range of power supply voltage changes, with good EMI resistance performance.
Adopting a 16 bit embedded microprocessor, it has fast computing speed, high accuracy, programmable low-frequency rectangular wave excitation, improved stability of flow measurement, and low power consumption.
Using SMD devices and surface mount technology, the circuit has high reliability.
There are no movable parts or flow blocking components inside the pipeline, and there is almost no additional pressure loss during measurement.
On site, the range can be modified online according to the actual needs of the user.
The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc.
High definition backlit LCD display, fully Chinese menu operation, easy to use, simple to operate, easy to learn and understand.
It has digital communication signal outputs such as RS485, RS232, Hart, and Modbus. (Optional)
It has self checking and self judging functions.
Hourly total volume recording function, recording the total flow volume in hours, suitable for time-sharing measurement system (Optional)
There are three integrators inside that can display the forward cumulative amount, reverse cumulative amount, and difference cumulative amount respectively. There is also a non power outage timer inside that can record 16 power outage times. (Optional)
Infrared handheld operator, 115KHZ communication speed, all functions of long-distance non-contact operation converter (Optional).

3. Product Performance:


Nominal diameter: DN4, DN6, DN10

Lining material: F46

Electrode material: 316 stainless steel, Hastelloy alloy, titanium, tantalum, platinum

Accuracy level: 0.5 grade, 1.0 grade

Working temperature: -30 ℃~+180 ℃

Working pressure: standard 1.6MPa (customized below 35MPa)

Output signal: 4-20mADC; RS485; HART

Protection level: standard IP65 (IP68 can be customized)

Power supply mode: 24VDC, battery, 220V

Connection type: using flange and threaded connection


4. Technical Specifications:

Nominal diameter(mm)Pipeline type: DN4DN3000
(Special specifications can be customized)Insertion type: DN100DN3000
Flow direction:Positive, negative, net flow
Range ratio:150:1
Repetitive error:± 0.1% of the measured value
Accuracy grade:Pipeline type: 0.5 grade, 1.0 grade
Temperature of the tested medium:Ordinary rubber lining: 20~+60
High temperature rubber lining: -20~+90
PTFE lining: -30~+100
High temperature PTFE lining: -20~+180
Rated working pressure:DN6DN80: ≤1.6MPa
(High pressure customizable)DN100DN250: ≤1.0MPa

DN300DN1200: ≤0.6MPa
Flow velocity range:0.1-15m/s
Conductivity range:The conductivity of the measured fluid ≥5μs/cm
Current output:Load resistance010mA: 01.5kΩ
420mA: 0750 kΩ
Digital frequency output:The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the maximum current at the collector is 250mA.
Power supply:AC220V,DC24V or 3.6V battery
Require the length of the straight pipeSection to be ≥ 5DN upstream and ≥ 2DN downstream
Connection method:The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988
Explosion proof grade:mdIIBT4
Protection level:IP65, specially customized up to IP68
Environmental temperature:-25~+60℃
Relative temperature:5%~95%
Total power consumption: less than 20W20W


5. Selection


① Selection code




ModelDescription
HQLDE —Rate of flow-□-□
HQLDR —Heat quantity-□-□
Path diameter












10-2200mm
TypeSElectromagnetic flowmeter (ordinary integrated type)
BStainless steel electromagnetic flowmeter
CInsertion type electromagnetic flowmeter
DClamp type electromagnetic flowmeter
EFire specific electromagnetic flowmeter
FSmall caliber electromagnetic flowmeter
GSanitary clamp electromagnetic flowmeter
HBattery powered electromagnetic flowmeter
LSplit type electromagnetic flowmeter
JHigh pressure electromagnetic flowmeter
KWireless remote electromagnetic flowmeter
ISolar powered electromagnetic flowmeter
Installation methodFFlange installation
LThreaded installation
KClamp installation
Electrode materialMStainless steel
TTi (Titanium)
DTa (Tantalum)
HHastelloy alloy
PPt (Platinum)
NNi (Nickel)
ATungsten carbide (wear-resistant)
Output method0No output
14-20mA/1-5KHz
24-20mA
324V 4G Wireless remote transmission
4Battery powered 4G wireless remote transmission
Lining materialXRubber
FPTFE
PF46 (High temperature)
JPFA (Wear resistant)
T
Ceramics
On site display0No on-site display
1On site display
Communication method0No communication
1RS485
2RS232
3Mobdus
4Hart
Grounding0No grounding ring
1Have grounding ring
2Have grounding electrode
Upper limit rate of flow(n)Upper limit flow rate (range)
m3/h
Work pressureA0.6MPa
B1.0 MPa
C1.6 MPa
D2,5 MPa
Measurement accuracy10.2
20.5
31
4
1.5
5
2
6
2.5
Medium temperatureL0-80
H0-150
Power supply methodDC24VDC
AC220VAC
DBattery-powered
TSolar-powered


Selection of caliber and flow rate


Nominal diameter (mm)Measurable flow range (m³/h)Effective measurement of flow range (m³/h)Nominal diameter (mm)Measurable flow range (m³/h)Effective measurement of flow range (m³/h)
40.01350.45220.01350.45222508.8313211952.98751766
60.03051.01730.03051.017330012.717305276.3022543
80.05431.80860.05431.808635017.314154103.863461
100.01423.39120.08482.82640022.615425135.654521
150.03187.63020.19086.358545028.626867171.685722
200.056613.56480.339211.30450035.338478211.957065
250.088321.1950.529817.662560050.8712208305.210173
320.144734.72580.868229.938270069.2416616415.413847
400.226154.25921.356545.21680090.4421703542.618086
500.353384.782.119570.65900114.4627468686.722890
650.5970143.283.5819119.391000141.333912847.828260
800.9044217.035.4259180.861200203.548833122140694
1001.413 339.128.478282.6140027766467166255389
1252.2079529.8713.2468441.561600361.886814217172345
1503.179376319.0755635.851800457.9109874274791562
2005.652135633.9121130.4