2.252kΩ Epoxy Encapsulated NTC Human Body Cavity Medical Temperature Sensor

Brand Name:JP SENSOR
Certification:CE, ISO13485, ISO9001
Model Number:JP401
Minimum Order Quantity:500PCS
Delivery Time:2-7days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Building No.2, Jinhui Photoelectric Industrial Park, Intersection of Paihe Avenue and Jixian Rd, Feixi, Hefei, Anhui, China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

2.252kΩ Epoxy Encapsulated NTC Human Body Cavity Medical Temperature Sensor


JP401 SERIES

2.252KΩ

25℃~45℃ (±0.1℃)


Brief Introduction:

Medical human body cavity temperature sensor ( esophageal/ rectal temperature probe) be used for human body cavity temperature measurement, Used for the patient monitors. The sensor is composed of epoxy beads and a Mono audio plug of 6.3mm. Meanwhile, we also accept customized plugs or connectors. The rated resistance value is 2.252kΩ. The measured temperature tolerance is within (25~45)℃ ±0.1℃, which is compatible with the replacement YSI400 series sensor.



Features:

Epoxy encapsulation

Reusability

Temperature tolerance

(25~45)℃±0.1℃

Operating temperature range: 0℃~50℃



Application:

Suitable for medical monitoring equipment



Structure and Dimensions:(Unit: mm)


No.NameMaterial SpecificationQTY.Remarks
1ChipNTC1/
2ProbeEpoxy Resin1Gray
3Wire24AWG/1C OD3.1 Shielded round sheath wire1Gray
4Plug6.3MP-φ6.3*31-501Gray

Standard packing (inner packing): 1 pcs/polybag



Operation Notice:

1. Application: Temperature measure ; 

2. The current flowing through the NTC is controlled within the Pmax range to avoid the measurement error caused by the self-heating of the component.

3. Avoid excessive heat shock, The hot air blow should beat at least 30mm to the probe in case the heat shrink protection tube needs to be attached.

4. Storage Temperature 0℃~50℃,30%~80%RH; Avoid a corrosive gas and sunlit environment; After opening the package, it needs to be sealed again.

5. According to the structure of the Glass coating NTC thermistor, when the end-user installs, to avoid the epoxy head being subjected to too much tensile force and bending force from the lead wire, The lead wire shall be controlled at a bending point or a force point on a lead wire 6mm or less below the sealing head. So as not to hurt the chip, resulting in resistance drifting and even open circuit, especially when the component is heated.



Product Images: