Add to Cart
Eltek Rectiverter Indoor system Scalable system 18kva 36kva 54kva
72kva with single AC input (CTER2442.4xxx CTER3642.4xxx
CTER4842.4xxx )
The scalable Rectiverter indoor system provides AC backup power for 400 VAC 3-phase or 230 VAC 1-phase loads, and 48 VDC power for battery charging and optional DC loads
The systems are available in three configurations with maximum AC
output power up to 36, 54 or 72 kVA. AC distributions are
integrated in the cabinet with possible 3 phase or 1 phase load
breakers.
In combination with AC output the system can also feed DC loads up
to 57,6 kW with built in DC distribution for -48 VDC loads.
l 400 VAC 3 phase (Y) input
l 400 VAC 3 phase (Y) output
l 48 VDC input/output
l Max 72 kVA / 57,6 kW AC output
l Max 57,6 kW DC output
l AC distribution
l DC distribution option
l Manual bypass option
l Up to 4 battery strings
l Built in transfer technology
l 150% overload capability, 15S
l 600% quick trip current 20 ms
l Hot pluggable
l Smartpack2 controller
l Operates in paralell with Flatpack2 rectifiers
l Global compliance
l Patented HE technology
TELECOM-MOBILE/WIRELESS
· LTE/4G/WiMAX
· Distributed antenna system
· Broadband
· Radio base stations/cell sites
RAILWAY & METRO INFRASTRUCTURE
· Control & protection
· Signaling
· GSM-R
· Safety Systems
POWER UTILITIES
· Control & protection
SCADA system
Parameters :
Scalable System 18-72 kVA, single input | ||||
Models / ordering information | 36 kVA | 54 kVA | 72 kVA | |
Product family | CTER2442.4xxx | CTER3642.4xxx | CTER4842.4xxx | |
AC OUTPUT DATA | ||||
Voltage (default) / (adjustable range)1) | 400 VAC 3 phase (Y) / 346-415 VAC | |||
Frequency (default inverter mode) | 50 Hz (adaptive) | |||
Frequency (set-able inverter mode) | 50Hz, 60Hz or last synced 50/60Hz (adaptive) | |||
Power maximum (continuous / overload (<15s) ) | 28,8 kW (36 kVA) / 48 kVA | 43,2 kW (54 kVA) / 72 kVA | 57,6 kW (72 kVA) / 96 kVA | |
Current maximum/phase(continuous overload(<15s)) | 52ARMS / 69,6ARMS | 78ARMS / 104,4ARMS | 104ARMS / 139,2ARMS | |
Current (maximum) Quick trip/phase (20ms) | 256A (6 x nominal) | 380A (6 x nominal) | 512A (6 x nominal) | |
Hold up (Voltage dips) (before switching to battery) | > 5 ms @ full load | |||
THD | < 1.5 % at resistive load | |||
Output features | Module: Fuse in L and N , Hot pluggable 1 pole or 3 pole AC distribution (connection directly on MCB or MCCB) Max breaker capacity according to recommended max breaker for rectiverter module | |||
DC OUTPUT DATA | ||||
Voltage (default) / (adjustable range) | 53.5 VDC / 43 - 58 VDC | |||
Power (maximum @nominal input) | 28,8 kW 2) | 43,2 kW 2) | 57,7 kW 2) | |
Current (maximum @VOUT ≤ 48 VDC) | 600 A 2) | 900 A 2) | 1200 A 2) | |
Hold up time, maximum output power | >10ms; VOUT > 41 VDC | |||
Output features | Short circuit proof, Over voltage Shutdown | |||
INPUT DATA | ||||
AC Mains Input Voltage(3 phase Y) | 320-475 VAC, | |||
AC Current/phase (depending on module type) | 56-96 ARMS 4) | 84-144 ARMS 4) | 112-192 ARMS 4) | |
Frequency (default: sync range) | 47-53 & 57-63 Hz | |||
Frequency (set-able: sync range) | 47-53 Hz, 57-63 Hz or both (adaptive) | |||
Power Factor / THD | > 0.99 at 50% load or more / < 3.5% | |||
DC Voltage nominal / extended range (no overload)3) | 45 - 58 VDC / 40 - 45 VDC | |||
DC Current (maximum)/ during overload (15s) | 768 A / 1080 A | 1152 A / 1620 A | 1536 / 2160 A | |
Input features | Module : Fuse in L and N, Hot pluggable, Varistor, Hot pluggable AC input individual screw terminals 120 mm2 for L1-L3, N & PE | |||
BATTERY BREAKER | ||||
1-pole battery breaker | 2*TPS 2 holder (800-1600 A) or 4*TPS 00 holder (250-600 A) | |||
OPTIONS | ||||
DC distribution (connection directly on breaker) | 1-125 A, 1 pole MCB breaker (max 30 pc 18 mm, max 20 pc 27 mm) | |||
DC distribution (bulk output) | 2*600 A (2*TPS 00 holder 250-600 A) | |||
Manual Bypass switch | 2*200 A | |||
LVBD (1-pole) | 1800 A | |||
OTHER SPECIFICATION | ||||
Efficiency | >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC)) | |||
Protection Class | IP 20 | |||
Connection | Top or Bottom connection | |||
Operating temperature | -40 to +55°C (-40 to +131°F), humidity 5 - 95% RH non-condensing | |||
Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing | |||
Dimensions[WxDxH] / Weight | 600 x 600x 2000mm (23,7 x 23,7 x 78,8”) / 300 kg (1100 lbs) | |||
DESIGN STANDARDS | ||||
Electrical safety | EN 60950-1, EN 62040-1 UPS safety | |||
EMC | ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15 EN 61000-6-1 /-2/-3/-4, EN62040-2 | |||
Environment | ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) Normal operating conditions to be as per IEC/EN 62040-3:2011 clause 4.1 RoHS (2011/65/EU) and WEEE (2002/96/EC) compliant | |||
1) Output voltage ranges configured in factory and have individual keying in top chassis 3) 40 - 45 VDC: reduced performance - no power boost and increased voltage THD on AC output. | 2) AC load has priority. Maximum available DC output power and current is dependent on instant AC load and AC input voltage; i.e maximum 800W/16,7A per module at full AC power and nominal input for 230VAC. 4) If DC voltage is pulled below 43V the input current may increase above this level |
* The indoor Rectiverter Cabinet with AC &DC feed in one
cabinet
Related Products :
Solutions
We provide a complete solutions including site survey, propose
professional plan according to customer’s request ,technical
support, and maintenance service for Telecommunication Companies in
and out of China. We have a competent team and a network of trusted
Partners around the world.
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios,
load and full load and current sharing test to ensure the quality
of the product.
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The
only difference is the price and schedule.
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction
document later to give you a more comprehensive and direct
introduction to our company’s information.
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent
renewal of supply, flexible provided according to different to
different needs of customers, providing different solutions.
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and
the freight needs to be borne by you.
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It
has already had a certain reputation. We will carefully analyze it.
If it is indeed our quality problem, you can rest assured that it
will do things according to the contract agreement and will never
let you have any after the worries, our service team will be happy
to serve you.
7 What about the quality ?
A:100% original with new package. we will test each item before
posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad
quality products within guarantee time.