Home /Wiring Accessories /

Eltek DC AC Inverters Flatpack2 Rectiverter 220V 230/1500 220/1200 115/750 220/600

Eltek DC AC Inverters Flatpack2 Rectiverter 220V 230/1500 220/1200 115/750 220/600

Brand Name:Eltek
Certification:CE,UL
Model Number:241123.141
Minimum Order Quantity:1 piece
Delivery Time:6-8 weeks
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: No 803,Unit 3 ,DaDou Road, Huihao Building .Fangshan District,Beijing,China
Supplier`s last login times: within 36 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details


Eltek AC DC inverter Flatpack2 Rectiverter 220V 230/1500 220/1200 & 115/750 220/600 (Part No.:241123.141)


Rectiverter 115V/750VA 220V/600W

Built on HE technology from the Flatpack2 HE rectifier family the Rectiverter 115V/750VA 220V/600W provides backed up power for 115 Vac an 220 Vdc loads with minimum losses and footprint.


Rectifier and inverter in one box

The Rectiverter is a 3 port device capable of charging the 220V battery and simultaneously provides power for the AC and DC loads. During mains outage the Rectiverter feeds AC loads using energy stored in the battery.


Key features

  • Unique 3-in-1 operationInverterRectifierPower source transferModular designHigh efficiencyGlobal compliancePatented technologyHot pluggableVoltage keying

Parameters :


Models / ordering information 230/1500 230/1500 230/1500 115/750 115/750 115/750

220/1200 220/150 220/0 220/600 220/75 220/0

Part number 241123.140 241123.141 241123.142 241123.140L 241123.141L 241123.142L
AC OUTPUT DATA
Voltage (default) / (adjustable range) 230 VAC / 200 - 240 VAC 115 VAC / 100 - 127 VAC
Frequency (default inverter mode) 50 Hz (adaptive) 60 Hz (adaptive)
Frequency (set-able inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive), 94-106Hz6)
Power maximum (continuous / overload (<15s) ) 1200 W (1500 VA) / 2000 VA 600 W (750 VA) / 1000 VA
Load sharing ±5% of active power from 10 to 100% load
Current maximum (continuous / overload (<15s) ) 6.5 ARMS / 8.7 ARMS
Current (maximum) Quick trip (20ms) 32 A (6 x nominal)
THD < 1.5 % at resistive load
Protection Fuse in L, Hot pluggable, Varistor
DC OUTPUT DATA
Voltage (default) / (adjustable range) 245 VDC / 194 - 290 VDC
Power (maximum @nominal input) 1200 W 1) 150 W 0 W 2) 600 W 1) 75 W 0 W 2)
Current (maximum @VOUT ≤ 216 VDC) 5.56 A 1) 0.69 A - 2.78 A 1) 0.34 A -
Hold up time, maximum output power >10ms; VOUT > 190 VDC (only in rectifier mode)
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load
Static Voltage regulation (10 - 100% load) ±0.5%
Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Ripple < 1 VPP , 30 MHz bandwidth
Protection Short circuit proof, Over voltage shutdown, Reversed polarity and Fuse
INPUT DATA
AC Mains Input Voltage (range / LV disconnect) 185 - 275 VAC / 170 VAC 95 - 140 VAC / 85 VAC
AC Current (maximum) 11.5 ARMS 9.1 ARMS 3) 8.2 ARMS 3) 11.3 ARMS 10.1 ARMS 3) 9.2 ARMS 3)
Frequency (default: sync range) 47-53 & 57-63 Hz 47-53 & 57-63 Hz
Frequency (set-able: sync range) 47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD > 0.99 at 50% load or more / < 3.5%
AC Input Protection Fuse in L and N, Hot pluggable, Varistor
DC Voltage nominal / extended range4) 204 - 290 VDC / 180 - 204 VDC
DC Current (maximum) 6.67 A / 9 A during overload (15s) 3.2 A / 4.5 A during overload (15s)
OTHER SPECIFICATION
Efficiency >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC))
Isolation 3.85 kVDC - ACIN/OUT to PE, 3.55 kVDC - ACIN/OUT to DC, 4.25 kVDC - ACIN/OUT to CAN/SYNC, 2.2 kVDC- DC to PE, 3.5 kVDC - DC to CAN/SYNC
Alarms: Red LED Low and high mains input voltage shutdown, High and low temperature shutdown, Rectiverter Failure, Alarm relay [NO max 75 VDC / 100 mA] Overvoltage shutdown on output, Fan failure, Low output voltage alarm, CAN bus failure, Sync bus (AC output OR DC output alarms) lost and Sync fail
Warnings: Yellow LED Rectiverter in power de-rate mode or in power or current limit mode on DC or AC port, Remote output current limit activated, Loss of CAN communication with controller
Normal operation: Green LED AC output and/or DC output on and ok
Operating temperature -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing
Temperature de-rating above 55°C (131°F) 1200W to 480W @ 75°C (167°F) for each, AC and DC, outputs (total power 2000W to 800W)
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.95 kg (4.3 lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC/EN 62040-1:2008+A1:2013 UL 60950-1:2014, UL1778:2014, CSA C22.2 No. 107.3-14

EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, IEC 61000-6-5:2015

EMC EN 62040-2:2006 (C1 emissions, C2/C3 immunity), FCC CFR 47 Part 15 EN50121 -2:2017+A1:2019, -4:2016+A1:2019, -5:2017+A1:20195)

EU 2015/863 (RoHS) & 2012/19/EU (WEEE) / ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)

Environment Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised

1) AC load has priority. Maximum available DC output power and current is dependent on 3) If DC port is overloaded pulling the voltage below 194V the input current may increase above this level. instant AC load and AC input voltage; i.e maximum 800W/7.4A at full AC power and nominal 4) Reduced performance - no over load support, and for 200 - 240 VAC output THD will increased and maximum input for 230VAC. output power de-rates (to 970W for 230 VAC @ 180 VDC) 5) to meet surge requirement of 4kV external surge

2) DC port must still be considered bi-directional port; voltage will present if mains powered protection is needed on AC ports 6) required FW version ≥ 1.10/1.10










Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.

FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.

2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.

3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.

4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.

5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.

6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.

7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.

8 How many months for guarantee ?
A: 1 year quality guarantee

9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.

China Eltek DC AC Inverters Flatpack2 Rectiverter 220V 230/1500 220/1200 115/750 220/600 supplier

Eltek DC AC Inverters Flatpack2 Rectiverter 220V 230/1500 220/1200 115/750 220/600

Inquiry Cart 0