Programmable Desktop Charger ENP-120 ENP-180 ENC-120 120W-360W

Brand Name:MEAN WELL
Certification:CE
Model Number:ENP-120
Minimum Order Quantity:1 piece
Delivery Time:8-10 weeks
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: No 803,Unit 3 ,DaDou Road, Huihao Building .Fangshan District,Beijing,China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details


Mean Well Portable Type Programmable Desktop Charger ENP-120 ENP-180 ENC-120 120W-360W Charger


Power:

ENP-120 / ENP-180 / ENP-240 / ENP-360

Charger:

ENC-120 / ENC-180 / ENC-240 / ENC-360


Features :

ENC: Programmable charger
ENP: Level VI desktop switching power supply

Charging voltage, charging current and timeout can be programmed through SBP-001

NTC for temperature compensation (ENC series)

Fanless design, and noise free

Protections: Short circuit, over voltage, over temperature protection (ENC/ENP series). Battery under voltage, battery over voltage, reverse polarity protection(only for ENC series)

Suitable for lead-acid batteries

3 years warranty


Technical


MODELENP-120-12ENP-120-24ENP-120-48

OUTPUT

DC VOLTAGE13.8V27.6V55.2V
RATED CURRENT8.7A4.3A2.2A
CURRENTRATED0 ~ 8.7A0 ~ 4.3A0 ~ 2.2A
PEAKNote.210.9A5.38A2.75A
WATTAGERATED120W119W121W
PEAKNote.2150.4W148.5W151.8W
RIPPLE & NOISE (max.) Note.3150mVp-p150mVp-p350mVp-p
VOLTAGE ADJ. RANGE11.5 ~ 15V23.5 ~ 30V47.5 ~ 58.8V
VOLTAGE TOLERANCE Note.4±1.0%±1.0%±1.0%
LINE REGULATION Note.5±0.5%±0.5%±0.5%
LOAD REGULATIONNote.6±2.0%±1.0%±0.5%
SETUP, RISE TIMENote.71000ms, 100ms at full load
HOLD UP TIME (Typ.)20ms at full load

INPUT

VOLTAGE RANGENote.890 ~ 264VAC127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)89.5%91%91.5%
AC CURRENT (Typ.)1.25A/115VAC0.63A/230VAC
INRUSH CURRENT (Typ.)COLD START 65A at 230VAC
LEAKAGE CURRENT<3.5mA / 240VAC
NO LOAD POWER CONSUMPTION<0.15W

PROTECTION

SHORT CIRCUITProtection type : Constant current limiting, recovers automatically after fault condition is removed

OVERLOAD

Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with auto-recovery after the peak load condition is removed
Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed
OVER VOLTAGE15.5 ~ 18.2V31 ~ 36.5V62.1 ~ 72.9V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATUREShut down O/P voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT±0.05%/℃ (0 ~ 50℃)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

(Note 9)

SAFETY STANDARDSIEC62368-1, UL62368-1, EAC TP TC 004 approved; Meet BS EN/EN62368-1
WITHSTAND VOLTAGEI/P-O/P:3KVACI/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

ParameterStandardTest Level / Note
ConductedBS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22)Class B
RadiatedBS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22)Class B
Harmonic CurrentBS EN/EN61000-3-2-----
Voltage FlickerBS EN/EN61000-3-3-----

EMC IMMUNITY

BS EN/EN55024
ParameterStandardTest Level / Note
ESDBS EN/EN61000-4-2Level 3, 8KV air ; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 2, 3V/m
EFT / BurstBS EN/EN61000-4-4Level 2, 1KV
SurgeBS EN/EN61000-4-5Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
ConductedBS EN/EN61000-4-6Level 2, 3Vrms
Magnetic FieldBS EN/EN61000-4-8Level 1, 1A/m
Voltage Dips and InterruptionsBS EN/EN61000-4-11

>95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

MTBF1997.9K hrs min.Telcordia SR-332 (Bellcore) ; 257.1K hrs min.MIL-HDBK-217F (25℃)
DIMENSION192*178*45.5mm (L*W*H)
PACKING0.98Kg; 10pcs/10.8Kg /1.38CUFT
NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Peak current or peak power up to 3 seconds is provided.

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4. Tolerance : includes set up tolerance, line regulation and load regulation.

5. Line regulation is measured from low line to high line at rated load.

6. Load regulation is measured from 0% to 100% rated load.

7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

8. Derating may be needed under low input voltages. Please check the derating curve for more details.

9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the

EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx









Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.

FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.

2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.

3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.

4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.

5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.

6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.

7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.







China Programmable Desktop Charger ENP-120 ENP-180 ENC-120 120W-360W supplier

Programmable Desktop Charger ENP-120 ENP-180 ENC-120 120W-360W

Inquiry Cart 0