Add to Cart
Eltek Rectifier Module Flatpack2 380/3000 380Vdc 3000W high efficiency (part no. 241119.825)
The Flatpack2 380V/3000W HE rectifier has high efficiency, OR-ing protection on output and high output power. Distribute pure battery backup DC voltage with a minimum of loss. Remove the low reliability DC-AC step in the central backup power system and maximize its reliability and efficiency.
Stack cabinets with up to 72 rectifiers to build large power systems monitored by the Smartpack2 controller.
Parameters :
Model | Flatpack2 380/3000 HE (UI) |
Part number | 241119.825 |
INPUT DATA | |
Voltage (nominal) | 176 - 277 VAC / 260 - 400 VD 1) C |
Voltage (range) | 85 - 305 VAC / 260 - 410 VD 1) C |
Frequency | 45 - 66 Hz / 15 - 18.5 Hz2) / DC1) |
Current (maximum) @ nominal input, full load | 18.2 ARMS |
Power Factor | > 0.99 at 50% load or more |
Protection | Fuse in L & N Varistor Disconnect when VIN is out of range |
OUTPUT DATA | |
Voltage (default) | 381 VDC |
Voltage (adjustable range) | 300 - 400 VDC |
# Pb cell supported | 156 - 168 3) |
Power continuous (maximum) | 3000 W |
Power @ 85 VAC / 85 VDC | 1200 W |
Current continuous (maximum) | 9 A (@VOUT < 336 VDC) / 7.9 A (@ VOUT = 381 VDC) |
Current sharing (10 - 100% load) | ±5% of maximum current from 10 to 100% load |
Static Voltage regulation (10 - 100% load) | ±0.5% |
Dynamic Voltage regulation | ±2.0% for 10-90% or 90-10% load variation, regulation time < 10 ms 5) |
Hold up time | > 20 ms; output voltage > 300 VDC at 1500 W load |
Ripple | < 1000 mVP-P , 30 MHz bandwidth |
Protection | Overvoltage shutdown, Hot plug-in - Inrush current limiting, ORing diode, Fuse5), Short circuit proof, High temperature protection, Overload shutdown4) |
OTHER SPECIFICATIONS | |
Efficiency @ 230 VAC / 380VDC input | 96.2% / 96.6% |
Isolation | 3.0 kVAC – input to output, 1.5 kVAC – input to earth, 1.5 kVDC – output to earth, 3.0 kVAC – CAN to primary, 3.0 kVAC – CAN to secondary |
Alarms (Red LED) | Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
Warnings (Yellow LED) | Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
Normal (Green LED) | Input and output ok |
Acoustic noise, at nominal input and full load | < 40dBA @Tambient< 25°C / <58dBA @ Tambient> 40°C |
MTBF (Telcordia SR-232 Iss.3 Meth. II Case L1) | 2 291 210h (@ Tambient = 25 °C) |
Operating temperature | -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing Output power de-rates linear from 3000W @ 50°C (122°F) to 980W @ 75°C(167°F) |
Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
Dimensions[WxHxD] / Weight | 109 x 41.5 x 327 mm (4.25 x 1.69 x 13”) / < 1.95 kg (4.3 lbs) |
DESIGN STANDARDS | |
Electrical safety | EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013, UL 60950-1:2014, CSA C22.2 No. 60950-1-07 |
EMC | EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010, IEC61000-6-5: 2015, EN 300 386:v1.6.1, FCC CFR 47 Part 15:2013 |
Environment | Tested according to: ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE) |
1) DC input support from revision 7 phased in via pn 241119.825IA. Support for lower DC voltages on request 2) 16 2/3 Hz frequency range only supported for 230 VAC +/-15%. Max available power de-rated to 1000 W 3) for 156 cells minimum test voltage is 1.923 V/cell. For 168 cell maximum boost voltage is 2.38 V/cell 4) if overloaded or load fault not cleared after 10s (defined as Vout < 200 VDC) it will permanently shut down (power cycle to reset) 5) from revision 9, phased in via pn 241119.825IA |
Solutions
We provide a complete solutions including site survey, propose
professional plan according to customer’s request ,technical
support, and maintenance service for Telecommunication Companies in
and out of China. We have a competent team and a network of trusted
Partners around the world.
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios,
load and full load and current sharing test to ensure the quality
of the product.
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The
only difference is the price and schedule.
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction
document later to give you a more comprehensive and direct
introduction to our company’s information.
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent
renewal of supply, flexible provided according to different to
different needs of customers, providing different solutions.
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and
the freight needs to be borne by you.
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It
has already had a certain reputation. We will carefully analyze it.
If it is indeed our quality problem, you can rest assured that it
will do things according to the contract agreement and will never
let you have any after the worries, our service team will be happy
to serve you.
7 What about the quality ?
A:100% original with new package. we will test each item before
posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad
quality products within guarantee time.