Product Details

Fast DNA Library Prep Kit for MGI

【Product Name】

Fast DNA Library Prep Kit for MGI

【Cat. No./Spec.】

KM001-A/24 rxns; KM001-B/96 rxns; sample sack/ 6 rxns

【Product Description】

Aiming at MGI high-throughput sequencing platform, this kit provides a convenient and universal DNA library construction scheme in one tube. It combines end repair and A-Tailing into one step, and reagents are highly premixed, greatly shortening the time of library construction and reducing the error caused by tedious steps. The end preparation, adapter ligation, amplification and purification of the fragmented double-stranded DNA can be performed within about 2 hours. Complete library quantification can be performed by dsDNA fluorescent dye method (e.g., Thermo Qubit Flex Fluorometer) or absolute quantification PCR after diluting the library to an appropriate concentration.

【Sample Type】

ApplicationSample TypeRecommended Amount
Whole genome sequencingHigh quality complex genomes50ng-1μg
Target capture sequencing of whole exomeHigh quality complex genomes10ng-1μg
Target capture sequencing of whole genomeFFPE DNA≥50ng
Target capture sequencing of whole genomecfDNA/ctDNA≥100pg
Whole genome sequencingMicrobial genome1ng-1μg
ChIP-SeqChIP DNA≥100pg
Targeted sequencingAmplicon≥100pg

【Storage Condition & Shelf Life】

All reagents should be stored at -20°C. Ligation Buffer is normal for crystals to precipitate at low temperatures, it should be balanced to room temperature before use. The product is valid for 12 months.

【Components】

Component24 rxns96 rxns
End Repair & A-Tailing Mix480 μl4×480 μl
Fast DNA Ligase120 μl2×240 μl
Fast Ligation Buffer600 μl4×600 μl
2× HIFI Library PCR Master Mix600 μl4×600 μl
Primer Mix for MGI*120 μl480 μl

* If there are more than one sample, #KM002 and #KM003 adapter primer mix is recommended. This kit provides a set of primers.

Note:recommended selection beads: #NC1011 GDSPure DNA Selection Magbeads or AMPure XP beads.

【Notes】

1. We offer two types of Universal Adapter primers set (#KM002 and #KM003, purchased separately), but customers can also choose from other manufacturers or synthesize their own Adapter for the MGI sequencing platform. Too much Adapter will lead to the formation of Adapter dimer, and insufficient Adapter will lead to low library output. Therefore, appropriate Adapter concentration determines the concentration and quality of library. The recommended adapter concentrations for different amounts of DNA input are shown in the following table:

Table 1 Recommended Use Concentrations of Adapter

DNA InputRecommended Conc. for AdapterAdapter:Insert Mole RatioGDS Adapter Dilution Degrees*
1μg10μM10:1No dilution
500ng10μM20:1No dilution
250ng10μM40:1No dilution
100ng7.5μM100:13:4
50ng5μM200:11:2
25ng2.5μM200:11:4
1ng1μM200:11:10

* Expressed as the volume ratio of adapter to diluent

2. The enzyme used in 2× HIFI Library PCR Master Mix is a B family DNA polymerase, which has 5 '-3' polymerase and 3 '-5' exonuclease activities, but lacks 5 '-3' exonuclease activities. It has high fidelity and homogeneity, and strong sustainable synthesis ability. Strict control of the number of amplification cycles is particularly important for library output. The following table shows the recommended number of amplification cycles corresponding to different amounts of DNA input:

Table 2 Recommended Number of Amplification Cycles Corresponding to Different Sample Inputs

Input DNARecommended Number of Amplification Cycles
100ng Library1μg Library
1μg02-5
500ng02-5
250ng1-35-7
100ng2-46-8
50ng4-68-10
25ng5-79-12
10ng7-911-13
5ng9-1113-14
2.5ng10-1214-16
1ng11-1315-17

Note: 1. The above table shows the test results using 150bp standard DNA, which is for reference only.

2. If incomplete connectors are used, a minimum number of cycles (1-3) should be amplified to obtain a complete library.

3. If the quality of the input DNA is poor, or the size selection is carried out during the library construction, the number of amplification cycles should be appropriately increased.

【Standard Library Construction Process】

End Repair

Note: If the fragmented DNA exceeds 45 μl before this step, or the buffer is incompatible with the end repair buffer, a magnetic bead purification should be performed first.

1. Prepare the following reaction in a 200 μl PCR tube:

ReagentsVolume
Fragmented DNAVariable
End Repair & A-Tailing Mix20 μl
ddH2OTo 65 μl

2. Vortex gently and spin down briefly to mix well, centrifuge briefly and collect all the liquid to the bottom of the tube.

3. Perform the following reaction in a thermal cycler:

TemperatureTime
20°C15min
65°C15min
4°C

Adapter Ligation

1. Proceed with the ligation reaction as soon as possible after end preparation.

2. Dilute the adapter according to Table 1.

3. Prepare the following reaction system:

ReagentsVolume
End repair and A-Tailing products65 μl
Fast Ligation Buffer25 μl
Fast DNA Ligase5 μl
Adapter X for MGI5 μl
Total100 μl

4. Vortex gently and spin down briefly to mix well, centrifuge briefly and collect all the liquid to the bottom of the tube.

5. Perform the following reaction in a thermal cycler:

TemperatureTime
20°C15min
4°C

Recommended Solution for PCR Cleanup/Size Selection (the specific magnetic bead volume should be adjusted according to the actual sample size)

1. Prepare 100 μl ligation products into an appropriate centrifuge tube.

2. Add 100 μl of resuspended DNA selection magnetic beads to the sample. Gently blow with a pipette for 10 times (or vortex for 30 s). Incubate samples for 5 min at room temperature.

3. Place the tube on an appropriate magnetic rack to separate the beads from the supernatant. When the solution is clear, carefully remove and discard the supernatant with a pipette (do not discard beads).

4. Add 200 μl of 80% freshly prepared ethanol to the tube while in the magnetic rack. Incubate at room temperature for 30 s, and then carefully remove and discard the supernatant (do not disturb beads).

5. Repeat Step 4 once for a total of two washes.

Note: Be sure to remove all visible liquid after the second wash.

6. Air dry the beads until the surface of the magnetic beads has no obvious gloss while the tube is on the magnetic rack with the lid open.

Note: Do not overdry the beads, this may result in lower recovery of DNA. When the beads start to crack, they are too dry.

7. Remove the tube from the magnetic rack. Add 22 μl elution buffer (10mM Tris-HCl, pH8.0-8.5) to the tube. Mix well by pipetting up and down at least 10 times or on a vortex mixer for 30 s. Incubate for 3-5 min at room temperature.

8. Place the tube on the magnetic rack. After 5 min (or when the solution is clear), transfer 20 μl supernatant to a new tube. The selection is completed, and the selected DNA can be used for subsequent experiments or stored at -20°C for a long time.

Library Amplification

1. Prepare the following reaction in a 200 μl PCR tube:

ReagentsVolume
Ligation products after cleanup or size selection20 μl
2× HIFI Library PCR Master Mix25 μl
Primer mix for MGI5 μl
Total50 μl

2. Vortex gently and spin down briefly to mix well, centrifuge briefly and collect all the liquid to the bottom of the tube.

3. Perform the following reaction in a thermal cycler:

TemperatureTimeCycle Number
95°C3min1
98°C20sec

Select appropriate number of cycles according to Table 2

60°C15sec
72°C30sec
72°C5min1
4°C-

Recommended Solution for PCR Cleanup/Size Selection (the specific magnetic bead volume should be adjusted according to the actual sample size)

1. Prepare 50 μl ligation products into an appropriate centrifuge tube.

2. Add 45 μl of resuspended DNA selection magnetic beads to the sample. Gently blow with a pipette for 10 times (or vortex for 30 s). Incubate samples for 5 min at room temperature.

3. Place the tube on an appropriate magnetic rack to separate the beads from the supernatant. When the solution is clear, carefully remove and discard the supernatant with a pipette (do not discard beads).

4. Add 200 μl of 80% freshly prepared ethanol to the tube while in the magnetic rack. Incubate at room temperature for 30 s, and then carefully remove and discard the supernatant (do not disturb beads).

5. Repeat Step 4 once for a total of two washes.

Note: Be sure to remove all visible liquid after the second wash.

6. Air dry the beads until the surface of the magnetic beads has no obvious gloss while the tube is on the magnetic rack with the lid open.

Note: Do not overdry the beads, this may result in lower recovery of DNA. When the beads start to crack, they are too dry.

7. Remove the tube from the magnetic rack. Add 22 μl elution buffer (10mM Tris-HCl, pH8.0-8.5) to the tube. Mix well by pipetting up and down at least 10 times or on a vortex mixer for 30 s. Incubate for 3-5 min at room temperature.

8. Place the tube on the magnetic rack. After 5 min (or when the solution is clear), transfer 20 μl supernatant to a new tube. The selection is completed, and the selected DNA can be stored at 2-8°C for 1-2 weeks or stored at -20°C for a long time.

【Appendix】Recommended Scheme for Double-Sided Selection

If double-round selection is required, we provide the following scheme to select the appropriate magnetic bead volume according to the expected library size. The size selection can be performed before end repair or after amplification. Two or more double-round selection will greatly reduce the library yield.

Fill the library volume in the table below to 100 μl. Select the volume of magnetic beads in two rounds according to the expected library size. And carry out the selection operation according to the following instructions.

Table 3 Recommended Amount of Magnetic Beads for Double-Round Selection

Expected Library Size150bp200bp250bp300bp400bp500bp600bp700bp
Volume of Beads(μl)Round 110090807060555045
Round 23020202020151515

1. Fill the library volume to 100 μl in a 200μl PCR tube and labeled as A. Add a certain volume of Magnetic beads according to the Table 3 (Round 1) to the tube A. Gently blow with a pipette for 30 s. Incubate samples for 5 min at room temperature.

2. Place the tube A on an appropriate magnetic rack to separate the beads from the supernatant. When the solution is clear, carefully remove the supernatant to a new tube and label it as B. Discard beads.

3. Add a certain volume of Magnetic beads according to the Table 3 (Round 2) to the tube B. Gently blow with a pipette for 30 s. Incubate samples for 5 min at room temperature. Place the tube B on magnetic rack. When the solution is clear, carefully remove and discard the supernatant.

4. Add 200 μl of 80% freshly prepared ethanol to the tube B while in the magnetic rack. Incubate at room temperature for 30 s, and then carefully remove and discard the supernatant (do not disturb beads).

5. Repeat Step 6 once for a total of two washes.

Note: Be sure to remove all visible liquid after the second wash.

6. Air dry the beads until the surface of the magnetic beads has no obvious gloss while the tube B is on the magnetic rack with the lid open.

Note: Do not overdry the beads, this may result in lower recovery of DNA. When the beads start to crack, they are too dry.

7. Remove the tube B from the magnetic rack. Add 22 μl elution buffer to the tube. Mix well by pipetting up and down at least 10 times or on a vortex mixer for 30 s. Incubate for 3-5 min at room temperature.

Note: If targeted capture will not be performed, add elution buffer (10mM Tris-HCl, ph 8.0-8.5) for elution. Otherwise, sterilized ultrapure water should be used for elution.

  • Place tube B on the magnetic rack. Transfer 20 μl supernatant to a new tube.

For Research Use Only


GDSBio Is a high-tech enterprise focusing on research and development, production and sales of high-quality life science products. The company has a complete product line, with PCR technology as the core, focusing on general PCR, fluorescence quantitative PCR, NGS storage, nucleic acid electrophoresis and other molecular biology technologies, and has developed molecular research reagents, molecular in vitro diagnostic raw materials, nucleic acid extraction and detection reagents and other products.

Environmentally friendly and strong carton packing

China Cost-Effective Sequencing Library Construction Kit From Chinese Manufacturers supplier

Cost-Effective Sequencing Library Construction Kit From Chinese Manufacturers

Inquiry Cart 0