Otis Elevator Spare Parts GGDCB Drive Main PCB Board ABA/ACA/AEA26800AKT1/ADA26800AKT2

Brand Name:SULAB
Model Number:ABA/ACA/AEA26800AKT1/ADA26800AKT2
Minimum Order Quantity:1
Delivery Time:Normally 2-3 working days after payment
Payment Terms:Company Bank, Western union, alibaba, Paypal etc
Supply Ability:1000pcs per month
Contact Now

Add to Cart

Verified Supplier
Address: Wanda Square Plaza, Weiyang district, Xi'an City, Shaanxi China
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

Details for Otis Elevator Spare Parts GGDCB Drive Main PCB Board ABA/ACA/AEA26800AKT1/ADA26800AKT2


BrandSulab
DescriptionElevator PCB Board
Part No.ABA/ACA/AEA26800AKT1/ADA26800AKT2
MOQ1PC
TransportionTNT, UPS, DHL, Fedex, Air, Sea
ApplicableElevator
PackagesCarton, Wooden case, Pallet etc
Delivery TimeNormally 2-3 working days after payment
WarrantyOne year
Payment MethodCompany Bank, Western union, Paypal, Personal bank etc


Pictures for Otis Elevator Spare Parts GGDCB Drive Main PCB Board ABA/ACA/AEA26800AKT1/ADA26800AKT2


OTIS OVF30 inverter is the inverter equipped in the 300VF control system of the early OTIS elevator. Due to its long service life (at least 10 years), the probability of damage to the ABA26800XU1 (or XU2) board in the inverter is relatively high. I have repaired many inverters. Now I will share with you the faults that are easy to damage and difficult to find. If there are any deficiencies, please point them out.


Fault 1: Power on normally, the inverter main board displays X04A, and the UDX light on this board keeps turning on and off. At the same time, the UDX relay keeps pulling in, and the BRK light is not on.


Fault point: This fault is generally caused by a problem in the IGBT drive signal circuit to the driver board, which is generally caused by the increase in the resistance value of the R118-R124=499 ohm resistor. Replacing the bad resistor can solve the problem.


Fault 2: Power on normally, inverter mainboard displays X04A, start maintenance, the UDX light on this board keeps turning on and off, while the UDX relay keeps pulling in, and the BRK light turns on and off again.


Fault point: This fault is generally caused by the increase in the resistance of the current sampling resistor in the current detection circuit. If the resistance of resistors R146, R149, R152 increases, just replace them.