YJJ WDK-07 Electrochemical Oxygen Sensor Oxygen Battery Used for Measuring Oxygen Concentration In Medical Equipment - oxygengassensors

YJJ WDK-07 Electrochemical Oxygen Sensor Oxygen Battery Used for Measuring Oxygen Concentration In Medical Equipment

Brand Name:YJJ
Model Number:WDK-07
Minimum Order Quantity:1
Delivery Time:5-8 days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

Product Description:

YJJ WDK-07 Electrochemical Oxygen Sensor Oxygen Battery - Used for Measuring Oxygen Concentration In Medical Equipment


Features:

Oxygen Sensor
Full-scale linear output
Works without external power supply
Temperature compensation
Fast response
Accurate and reliable
Strong anti-interference ability
Product Description
The WDK-07 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration in medical equipment. The interface model is 5520257-2. It adopts a molded body design and features fast response and long service life. It can achieve domestic substitution and provides excellent quality for customers while reducing costs.
The difference between this sensor and the WDK-06 oxygen sensor lies in the pin definitions. Application scope
The WDK-07 oxygen sensor does not require an external power supply when in operation. It has been professionally and accurately calibrated and temperature compensated at the factory and can be used as a sensing component in oxygen analyzers, such as oxygen generators control devices, medical ventilators, anesthesia equipment, incubators, etc.
Measurement indicators 1
Working principle: Differential pressure type electrochemistry
Output voltage: 9 - 13 mV (in air)
Measurement range: 0 - 100%
Response time (T90): < 15 seconds
Linearity: Linear over the full range Electrical performance
Temperature compensation < 2% O2 equivalent (0 - 40 ℃)
Load resistance ≥ 10 kΩ
Interface P/N 5520257-2 Mechanical parameters
Shell material: White ABS
Weight: Approximately 40 grams Environmental factors
Operating temperature range: 0 - 50 ℃
Operating pressure range: 0.5 - 2.0 bar
Operating humidity range: 0 - 99% RH (no condensation)
Other indicators
Long-term drift in 100% O2 environment 2
(Voltage attenuation/year)
< 5%
Service life: 1.5×10^6 hours of 20 ℃ O2 (20 ℃)
0.8×10^6 hours of 40 ℃ O2
Shelf life: 12 months from the date of shipment


Specifications:


range0-1500mBar O2
response time<15s
Pressure range0.5-2Bar
The output9-13mV