SO2-B4 Electrochemical Sulfur Dioxide Gas Sensor For Air Quality Monitoring Flue Gas Analysis

Brand Name:PSR
Model Number:SO2-B4
Minimum Order Quantity:1PCS
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Place of Origin:UK
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

SO2-B4 Electrochemical Sulfur Dioxide Gas Sensor For Air Quality Monitoring Flue Gas Analysis


Technical Features:

  • High - precision Detection: Using proven fuel cell technology, with strong signal levels and low zero current, the resolution can reach < 10 ppb, which can meet the requirements of high - precision detection in air quality networks.
  • Good Linearity: The linearity error is 0 - 2 ppb at 100 ppm SO2, and it is linear in the range of 0 - 10 ppm SO2, which can ensure the accuracy of measurement results.
  • Reliable Performance: The sensor provides an electrolyte leak - free guarantee and reliable long - term detection performance. The leak - proof housing is molded with a color - coded top for easy identification.

Application Scenarios:

It is suitable for fixed - installation sensing heads, portable safety instruments, urban/indoor air monitoring and stack gas analyzers, etc., and can provide reliable data support for air quality monitoring and industrial emission detection.


Measuring Range100 ppm
Sensitivity275 - 475 nA/ppm (at 2 ppm SO2)
Response Time (t90)< 30 s (from zero to 2 ppm SO2)
Zero Current in Zero Air at 20℃-
Noise (±2 standard deviations, ppb equivalent)5
Resolution< 1 ppm
Linearity0 - 2 ppb error at 100 ppm SO2, linear at 0 and 10 ppm SO2
Over - gas Limit200 ppm
Zero Drift (ppb equivalent change/year in lab air)< ±20
Sensitivity Drift (% change/year in lab air, monthly test)< ±15
Operating Life> 36 months (until 50% of the original signal)
Sensitivity at - 20℃70 - 82% (output at - 20℃ / output at 20℃ @ 2 ppm SO2)
Sensitivity at 50℃95 - 110% (output at 50℃ / output at 20℃ @ 2 ppm SO2)
Zero at - 20℃ (nA change from 20℃)0 - 10
Zero at 50℃ (nA change from 20℃)10 - 30
Filter Capacity450 ppm·hrs
H2S Sensitivity (% measured gas @ 5 ppm H2S)< 2
NO2 Sensitivity (% measured gas @ 5 ppm NO2)< - 160
Cl2 Sensitivity (% measured gas @ 5 ppm Cl2)< - 40
NO Sensitivity (% measured gas @ 5 ppm NO)< - 2
CO Sensitivity (% measured gas @ 5 ppm CO)< 2
H2 Sensitivity (% measured gas @ 100 ppm H2)< 0.5
C2H4 Sensitivity (% measured gas @ 100 ppm C2H4)< 1
NH3 Sensitivity (% measured gas @ 20 ppm NH3)< 0.1
CO2 Sensitivity (% measured gas @ 5% CO2)< 0.1
Temperature Range- 30 to 50℃
Pressure Range80 - 120 kPa
Humidity Range15 - 90% RH (continuous)
Storage Period6 months (@3 - 20℃, stored in sealed pot)
Load Resistor33 - 100 Ω
Weight< 13 g