YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes


Features:

CITIPEL Sensor product introduction
The service life of the C/NLL Oxygen CiTiceL is inversely proportional to the amount of oxygen consumed by the sensor. Because City Technology does not have knowledge of the operating conditions of any particular application, the company cannot provide any guarantees about the service life of the sensors. However, the following guidelines should be used:
Under normal operating conditions (i.e. ppm level), the sensor has a large excess capacity and will only gradually lose sensitivity. However, it is recommended to replace the sensor annually to maintain the best sensitivity.
It is recommended not to use these sensors in ambient air, or to keep them in the air for long periods of time. This will greatly reduce the service life of the sensor.

2-electrode electrochemical
0-2 ppm O,
1000 ppm O.
Operating Principle
Measurement Range
Maximum Overload
Filter
Qutput Signa!
None
13 _17 mV in air with a 100
load resistor
< 20 seconds
< 6 hours
Response Time (T.)
Purge Time:
(Ambient air to <10 ppm)
Linearity Linear
ELECTRICAL
Recommended Load Resistor 10 Ω
MECHANICAL
Weight |32 g
Housing Material:
Nickel plated steel
Body
Current Collectors Nickel
Orientation Sensitivity None
ENVIRONMENTAL
Operating Temperature Range -20'C to +50°C
Temperature Coefficient
0.2% signal/°C
Recommended Storage Temp
0'C to 20°C
Atmospheric±10%
Operating Pressure Range
Operating Humidity Range
0-99% RH non-condensing
LIFETIME
Long Term Output Drift
Expected Operating Life
Storage Life
<5% signal losslyear
See below
6 months in CTL container


Specifications:

Orientation SensitivityNone
Current CollectorsNickel
BodyNickel plated steel
Weight32 g