Product Details
NE7-CO-H10000 Electrochemical gas sensor
Key Features:
- Anti-Interference Design:
- Four-electrode structure enables internal compensation for hydrogen
sensitivity, eliminating interference from unburned hydrogen (H₂)
in combustion processes. Suitable for complex scenarios like gas
equipment and industrial exhaust monitoring.
- Cross-sensitivity performance:
- No response: Cl₂, CH₄, C₂H₅OH, etc.
- Slight response: H₂ (100ppm ≈ <70ppm CO equivalent), NO (35ppm ≈
<7ppm CO equivalent), NO₂ (10ppm ≈ -0.5 to +1ppm CO equivalent).
- Environmental Adaptability:
- Temperature range: -20°C to +50°C with cold-start capability at
-20°C.
- Humidity impact: Stable performance in 15%–90% RH; output
fluctuation ≤5ppm under sudden humidity changes.
- Durability: Passed -20°C/50°C thermal shock test (10 cycles) with
minimal performance degradation.
- High Precision & Reliability:
- 0.5ppm resolution and repeatability < ±2%, suitable for
occupational safety (e.g., mines, chemical plants) and
environmental monitoring (e.g., indoor air quality).
- Built-in temperature compensation reduces zero drift caused by
ambient temperature changes.
Application Fields:
- Industrial Safety: CO leakage monitoring in gas boilers, furnaces,
power plants, etc.
- Environmental Monitoring: Indoor air quality detection, underground
parking ventilation control.
- Combustion Control: Combustion efficiency optimization for gas
water heaters, stoves (requires integration with O₂ sensors).
- Portable Devices: Handheld CO detectors, multi-gas composite
monitors.
Physical Parameters:
- Dimensions: Industrial-standard design compatible with 主流 gas
detection equipment interfaces.
- Weight: Approximately 9.9g (reference for similar electrochemical
sensors).
- Interface: Standard pin-type design for plug-and-play integration.
Usage Recommendations:
- Calibration Cycle: Perform zero and span calibration every 6 months
to ensure long-term accuracy.
- Storage Conditions: Store at -20°C to +50°C with humidity <60%
RH when unused; avoid prolonged exposure to high humidity or
polluted gases.
- Lifespan Management: Typical service life is 24 months (dependent
on usage environment); monitor sensitivity decay regularly.
| Detected Gas | Carbon Monoxide (CO) |
| Measurement Range | 0 - 1000 ppm (standard model) |
| Maximum Overload | 2000 ppm |
| Resolution | 0.5 ppm |
| Response Time (T90) | < 35 seconds |
| Output Signal | 100±20 nA/ppm (typical value) |
| Baseline Range (Clean Air) | -3 to +15 ppm (equivalent CO concentration) |
| Zero Drift | < 1 ppm (-20°C to +50°C) |
| Operating Temperature | -20°C to +50°C |
| Operating Humidity | 15% - 90% RH (non-condensing) |
| Long-term Stability | Signal loss < 5%/year |
Company Profile
Yijiajie Electronics is a full range of silicon pressure sensors
from the United States, FREESCALE/, GE, MEAS, SMI, and a full range
of sensing and control products from the United States pressure,
temperature and humidity, gas flow, current, Hall effect, etc.,
Japan HAMAMATSU flame, UV sensors, photodiodes, Japan FIGARO, UK
CITY, ALPHASENSE full range of semiconductors, catalytic,
electrochemical gas sensors, French HUMIREL/MEAS humidity sensors
and other international well-known companies authorized agents or
distributors, to provide customers with product information,
products Solutions, product selection, supply guarantee and
logistics services, etc.